由ISO 5832-9不锈钢制成的小直径髓内钉的研制。

A M Ingman
{"title":"由ISO 5832-9不锈钢制成的小直径髓内钉的研制。","authors":"A M Ingman","doi":"10.1046/j.1440-1622.2000.01790.x","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>In order to improve strength in small diameter intramedullary nails, a system was designed in which the implants were manufactured from 30% coldworked ISO 5832-9 stainless steel.</p><p><strong>Methods: </strong>Nail diameters were 9 and 10 mm for the femur, and 8 and 9 mm for the tibia. The nails were solid rods and the screws were partially threaded. Pre-clinical bending yield tests established that the 8-, 9- and 10-mm diameter rods had strengths comparable, respectively, with 10-, 12- and 14-mm diameter Grosse-Kempf nails. Forty-eight femoral and 98 tibial shaft acute fractures were treated with this system. Postoperatively, patients were allowed to gently bear weight as tolerated.</p><p><strong>Results: </strong>There was one broken nail, occurring 10 months after femoral nailing. There were six broken screws, occurring between 3 and 6 months postoperatively in two patients and after more than 6 months in four patients. The broken screws had no adverse clinical effect. Five patients required late bone grafting or exchange nailing, and 15 patients required dynamization.</p><p><strong>Conclusion: </strong>This design of small diameter locked intramedullary nails was strong enough to allow early weightbearing.</p>","PeriodicalId":22494,"journal":{"name":"The Australian and New Zealand journal of surgery","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2000-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1046/j.1440-1622.2000.01790.x","citationCount":"4","resultStr":"{\"title\":\"Development of small diameter intramedullary nails made from ISO 5832-9 stainless steel.\",\"authors\":\"A M Ingman\",\"doi\":\"10.1046/j.1440-1622.2000.01790.x\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>In order to improve strength in small diameter intramedullary nails, a system was designed in which the implants were manufactured from 30% coldworked ISO 5832-9 stainless steel.</p><p><strong>Methods: </strong>Nail diameters were 9 and 10 mm for the femur, and 8 and 9 mm for the tibia. The nails were solid rods and the screws were partially threaded. Pre-clinical bending yield tests established that the 8-, 9- and 10-mm diameter rods had strengths comparable, respectively, with 10-, 12- and 14-mm diameter Grosse-Kempf nails. Forty-eight femoral and 98 tibial shaft acute fractures were treated with this system. Postoperatively, patients were allowed to gently bear weight as tolerated.</p><p><strong>Results: </strong>There was one broken nail, occurring 10 months after femoral nailing. There were six broken screws, occurring between 3 and 6 months postoperatively in two patients and after more than 6 months in four patients. The broken screws had no adverse clinical effect. Five patients required late bone grafting or exchange nailing, and 15 patients required dynamization.</p><p><strong>Conclusion: </strong>This design of small diameter locked intramedullary nails was strong enough to allow early weightbearing.</p>\",\"PeriodicalId\":22494,\"journal\":{\"name\":\"The Australian and New Zealand journal of surgery\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2000-03-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1046/j.1440-1622.2000.01790.x\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"The Australian and New Zealand journal of surgery\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1046/j.1440-1622.2000.01790.x\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"The Australian and New Zealand journal of surgery","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1046/j.1440-1622.2000.01790.x","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

摘要

背景:为了提高小直径髓内钉的强度,设计了一种系统,其中种植体由30%冷加工的ISO 5832-9不锈钢制造。方法:股骨钉直径分别为9、10 mm,胫骨钉直径分别为8、9 mm。钉子是实心棒,螺丝是部分螺纹的。临床前弯曲屈服测试表明,8,9,10 -mm直径棒的强度分别与10-mm, 12- mm和14-mm直径Grosse-Kempf钉子相当。应用该系统治疗股骨骨折48例,胫骨骨折98例。术后,允许患者在耐受的情况下轻负重。结果:骨折1例,发生于股骨内钉10个月后。6例螺钉断裂,2例发生在术后3 ~ 6个月,4例发生在术后6个月以上。骨折螺钉无不良临床反应。5例患者需要后期植骨或交换钉,15例患者需要动力化。结论:这种设计的小直径锁定髓内钉足够坚固,可以早期负重。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Development of small diameter intramedullary nails made from ISO 5832-9 stainless steel.

Background: In order to improve strength in small diameter intramedullary nails, a system was designed in which the implants were manufactured from 30% coldworked ISO 5832-9 stainless steel.

Methods: Nail diameters were 9 and 10 mm for the femur, and 8 and 9 mm for the tibia. The nails were solid rods and the screws were partially threaded. Pre-clinical bending yield tests established that the 8-, 9- and 10-mm diameter rods had strengths comparable, respectively, with 10-, 12- and 14-mm diameter Grosse-Kempf nails. Forty-eight femoral and 98 tibial shaft acute fractures were treated with this system. Postoperatively, patients were allowed to gently bear weight as tolerated.

Results: There was one broken nail, occurring 10 months after femoral nailing. There were six broken screws, occurring between 3 and 6 months postoperatively in two patients and after more than 6 months in four patients. The broken screws had no adverse clinical effect. Five patients required late bone grafting or exchange nailing, and 15 patients required dynamization.

Conclusion: This design of small diameter locked intramedullary nails was strong enough to allow early weightbearing.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Hiatus. ELECTROSURGERY: A SHORT HISTORY1 EUTHANASIA: A POINT OF VIEW1 DISSEMINATED INTRAVASCULAR COAGULATION CADE A model for reflecting upon the ethical dilemma of hands-on teaching of surgery
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1