{"title":"一个有多例超敏性肺炎的设施的气溶胶测绘:雾减少的证明和可能的剂量/反应关系。","authors":"Dennis M O'Brien","doi":"10.1080/10473220390237656","DOIUrl":null,"url":null,"abstract":"<p><p>Recent outbreaks of hypersensitivity pneumonitis (HP) have been associated with exposures to metalworking (MWF) fluid aerosols. Mycobacteria present in mismanaged fluids have been suggested as the likely culprit. In January 2001, three machinists at a machining plant were hospitalized with HP. Subsequently, additional HP cases developed as well as cases of bronchitis and occupational asthma. In October 2001, an aerosol concentration map was constructed to advise on priorities for corrective actions. In April 2002 after installation of mist collectors, a second map was generated. Mist reductions varied from about 75 percent to an increase of about 20 percent. Mist concentrations increased in the areas near an uncontrolled transfer line. Subsequent to the first mapping exercise, the exposures of 30 HP cases were classified as low, medium, and high based on job location and the map. There were 6 cases among low exposure jobs (4% of exposed), 14 cases among medium exposure jobs (19% of exposed), and 10 cases among high exposure jobs (34% of exposed), suggesting a relation between exposure to contaminated metalworking fluid mist and the development of HP. A combination of interventions (fluid management, mist control, improved fresh air ventilation, and medical surveillance/restriction) eliminated any new cases 11 months after the first diagnosis of HP.</p>","PeriodicalId":8182,"journal":{"name":"Applied occupational and environmental hygiene","volume":"18 11","pages":"947-52"},"PeriodicalIF":0.0000,"publicationDate":"2003-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1080/10473220390237656","citationCount":"42","resultStr":"{\"title\":\"Aerosol mapping of a facility with multiple cases of hypersensitivity pneumonitis: demonstration of mist reduction and a possible dose/response relationship.\",\"authors\":\"Dennis M O'Brien\",\"doi\":\"10.1080/10473220390237656\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Recent outbreaks of hypersensitivity pneumonitis (HP) have been associated with exposures to metalworking (MWF) fluid aerosols. Mycobacteria present in mismanaged fluids have been suggested as the likely culprit. In January 2001, three machinists at a machining plant were hospitalized with HP. Subsequently, additional HP cases developed as well as cases of bronchitis and occupational asthma. In October 2001, an aerosol concentration map was constructed to advise on priorities for corrective actions. In April 2002 after installation of mist collectors, a second map was generated. Mist reductions varied from about 75 percent to an increase of about 20 percent. Mist concentrations increased in the areas near an uncontrolled transfer line. Subsequent to the first mapping exercise, the exposures of 30 HP cases were classified as low, medium, and high based on job location and the map. There were 6 cases among low exposure jobs (4% of exposed), 14 cases among medium exposure jobs (19% of exposed), and 10 cases among high exposure jobs (34% of exposed), suggesting a relation between exposure to contaminated metalworking fluid mist and the development of HP. A combination of interventions (fluid management, mist control, improved fresh air ventilation, and medical surveillance/restriction) eliminated any new cases 11 months after the first diagnosis of HP.</p>\",\"PeriodicalId\":8182,\"journal\":{\"name\":\"Applied occupational and environmental hygiene\",\"volume\":\"18 11\",\"pages\":\"947-52\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2003-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1080/10473220390237656\",\"citationCount\":\"42\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Applied occupational and environmental hygiene\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1080/10473220390237656\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Applied occupational and environmental hygiene","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1080/10473220390237656","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 42

摘要

最近爆发的过敏性肺炎(HP)与接触金属加工(MWF)流体气溶胶有关。存在于管理不善的液体中的分枝杆菌被认为是可能的罪魁祸首。2001年1月,一家机加工厂的三名机械师因感染惠普而住院。随后,又出现了HP病例以及支气管炎和职业性哮喘病例。二零零一年十月,我们绘制了一幅气溶胶浓度图,就纠正措施的优先次序提供意见。2002年4月,在安装了雾收集器后,生成了第二张地图。雾气减少幅度从75%到20%不等。在不受控制的输电线附近,雾浓度增加。在第一次绘制地图之后,根据工作地点和地图,将30例HP病例的暴露程度分为低、中、高三个等级。在低暴露工作中有6例(暴露的4%),在中等暴露工作中有14例(暴露的19%),在高暴露工作中有10例(暴露的34%),表明暴露于受污染的金属加工液雾与HP的发展之间存在关系。综合干预措施(液体管理、雾气控制、改善新鲜空气通风和医疗监测/限制)在首次诊断HP后11个月消除了任何新病例。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Aerosol mapping of a facility with multiple cases of hypersensitivity pneumonitis: demonstration of mist reduction and a possible dose/response relationship.

Recent outbreaks of hypersensitivity pneumonitis (HP) have been associated with exposures to metalworking (MWF) fluid aerosols. Mycobacteria present in mismanaged fluids have been suggested as the likely culprit. In January 2001, three machinists at a machining plant were hospitalized with HP. Subsequently, additional HP cases developed as well as cases of bronchitis and occupational asthma. In October 2001, an aerosol concentration map was constructed to advise on priorities for corrective actions. In April 2002 after installation of mist collectors, a second map was generated. Mist reductions varied from about 75 percent to an increase of about 20 percent. Mist concentrations increased in the areas near an uncontrolled transfer line. Subsequent to the first mapping exercise, the exposures of 30 HP cases were classified as low, medium, and high based on job location and the map. There were 6 cases among low exposure jobs (4% of exposed), 14 cases among medium exposure jobs (19% of exposed), and 10 cases among high exposure jobs (34% of exposed), suggesting a relation between exposure to contaminated metalworking fluid mist and the development of HP. A combination of interventions (fluid management, mist control, improved fresh air ventilation, and medical surveillance/restriction) eliminated any new cases 11 months after the first diagnosis of HP.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
A Field Evaluation of Mandelic Acid in Urine as a Compliance Monitor for Styrene Exposure The Impact of Boundary Layer Separation on Local Exhaust Design and Worker Exposure Air-Lead Particle Sizes in Battery Manufacturing: Potential Effects on the OSHA Compliance Model Risk Assessment for Carcinogens: A Comparison of Approaches of the ACGIH and the EPA Industrial Ventilation News Digest
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1