处理对添加硅酮腻子弹性的影响。

Leonardo Eloy Rodrigues Filho, Antonio Muench, Carlos Francci, Angelika Katia Luebke, Andréia Aparecida Traina
{"title":"处理对添加硅酮腻子弹性的影响。","authors":"Leonardo Eloy Rodrigues Filho,&nbsp;Antonio Muench,&nbsp;Carlos Francci,&nbsp;Angelika Katia Luebke,&nbsp;Andréia Aparecida Traina","doi":"10.1590/s1517-74912003000300010","DOIUrl":null,"url":null,"abstract":"<p><p>The handling of vinyl polysiloxane (addition silicone) impression putties with latex gloves is said to interfere with the setting of these impression materials. The aim of this study is to evaluate the effect of handling techniques on the setting of vinyl polysiloxane impression putties using several types of gloves. The setting of these materials was evaluated by means of an elasticimeter. Four vinyl polysiloxane putty impression materials and five brands of gloves (one made of vinyl, one of synthetic rubber, and three of natural rubber) were studied. Based on the type of glove, they were previously washed or not, and a spatula was used or not for initial mixing (before handmixing). The vinyl, the synthetic and one of the natural rubber gloves did not require the previous washing procedure and/or the use of a spatula for initial mixing. Two other natural rubber gloves - depending on the silicone -, showed satisfactory results only when the initial mixing was performed with a spatula. It was concluded that setting inhibition depends on the kind of vinyl polysiloxane impression material and the kind of gloves used, but when the initial mixing was performed with the spatula this setting inhibition was overcome. The results of this study also showed that it is possible to associate cross-contamination control and satisfactory performance of addition silicone putty materials. When doubts arise from the compatibility between vinyl polysiloxane impression putties and gloves, the initial mixing should be performed with a spatula.</p>","PeriodicalId":35295,"journal":{"name":"Pesquisa odontologica brasileira = Brazilian oral research","volume":"17 3","pages":"254-60"},"PeriodicalIF":0.0000,"publicationDate":"2003-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1590/s1517-74912003000300010","citationCount":"1","resultStr":"{\"title\":\"The influence of handling on the elasticity of addition silicone putties.\",\"authors\":\"Leonardo Eloy Rodrigues Filho,&nbsp;Antonio Muench,&nbsp;Carlos Francci,&nbsp;Angelika Katia Luebke,&nbsp;Andréia Aparecida Traina\",\"doi\":\"10.1590/s1517-74912003000300010\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The handling of vinyl polysiloxane (addition silicone) impression putties with latex gloves is said to interfere with the setting of these impression materials. The aim of this study is to evaluate the effect of handling techniques on the setting of vinyl polysiloxane impression putties using several types of gloves. The setting of these materials was evaluated by means of an elasticimeter. Four vinyl polysiloxane putty impression materials and five brands of gloves (one made of vinyl, one of synthetic rubber, and three of natural rubber) were studied. Based on the type of glove, they were previously washed or not, and a spatula was used or not for initial mixing (before handmixing). The vinyl, the synthetic and one of the natural rubber gloves did not require the previous washing procedure and/or the use of a spatula for initial mixing. Two other natural rubber gloves - depending on the silicone -, showed satisfactory results only when the initial mixing was performed with a spatula. It was concluded that setting inhibition depends on the kind of vinyl polysiloxane impression material and the kind of gloves used, but when the initial mixing was performed with the spatula this setting inhibition was overcome. The results of this study also showed that it is possible to associate cross-contamination control and satisfactory performance of addition silicone putty materials. When doubts arise from the compatibility between vinyl polysiloxane impression putties and gloves, the initial mixing should be performed with a spatula.</p>\",\"PeriodicalId\":35295,\"journal\":{\"name\":\"Pesquisa odontologica brasileira = Brazilian oral research\",\"volume\":\"17 3\",\"pages\":\"254-60\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2003-07-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1590/s1517-74912003000300010\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Pesquisa odontologica brasileira = Brazilian oral research\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1590/s1517-74912003000300010\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2003/12/16 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q2\",\"JCRName\":\"Dentistry\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Pesquisa odontologica brasileira = Brazilian oral research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1590/s1517-74912003000300010","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2003/12/16 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"Dentistry","Score":null,"Total":0}
引用次数: 1

摘要

用乳胶手套处理乙烯基聚硅氧烷(添加硅酮)压模腻子据说会干扰这些压模材料的定型。本研究的目的是评估使用几种类型的手套处理技术对乙烯基聚硅氧烷压模腻子固化的影响。用弹性计评价了这些材料的凝固性。研究了四种乙烯基聚硅氧烷腻子压模材料和五种牌号(乙烯基、合成橡胶和天然橡胶)的手套。根据手套的类型,它们之前是否清洗过,并且在初始混合(手动混合之前)是否使用抹刀。乙烯基、合成橡胶和天然橡胶手套中的一种不需要之前的洗涤程序和/或使用抹刀进行初始混合。另外两种天然橡胶手套——取决于硅胶——只有在用抹刀进行初始混合时才显示出令人满意的结果。结果表明,凝固抑制作用取决于乙烯基聚硅氧烷压模材料的种类和使用的手套种类,但当用抹刀进行初始混合时,这种凝固抑制作用被克服了。研究结果还表明,添加有机硅腻子材料可以将交叉污染控制与令人满意的性能联系起来。当对乙烯基聚硅氧烷压模腻子与手套之间的相容性产生疑问时,应使用抹刀进行初始混合。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
The influence of handling on the elasticity of addition silicone putties.

The handling of vinyl polysiloxane (addition silicone) impression putties with latex gloves is said to interfere with the setting of these impression materials. The aim of this study is to evaluate the effect of handling techniques on the setting of vinyl polysiloxane impression putties using several types of gloves. The setting of these materials was evaluated by means of an elasticimeter. Four vinyl polysiloxane putty impression materials and five brands of gloves (one made of vinyl, one of synthetic rubber, and three of natural rubber) were studied. Based on the type of glove, they were previously washed or not, and a spatula was used or not for initial mixing (before handmixing). The vinyl, the synthetic and one of the natural rubber gloves did not require the previous washing procedure and/or the use of a spatula for initial mixing. Two other natural rubber gloves - depending on the silicone -, showed satisfactory results only when the initial mixing was performed with a spatula. It was concluded that setting inhibition depends on the kind of vinyl polysiloxane impression material and the kind of gloves used, but when the initial mixing was performed with the spatula this setting inhibition was overcome. The results of this study also showed that it is possible to associate cross-contamination control and satisfactory performance of addition silicone putty materials. When doubts arise from the compatibility between vinyl polysiloxane impression putties and gloves, the initial mixing should be performed with a spatula.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
3.80
自引率
0.00%
发文量
0
期刊介绍: Pesquisa Odontológica Brasileira is a new quarterly published journal (January-March, April-June, July-September, October-December), with an annual supplement (Anais da Reunião de Pesquisa Odontológica da SBPqO), by the Sociedade Brasileira de Pesquisa Odontológica [Brazilian Society of Odontological Research] and University of São Paulo. It replaces Revista de Odontologia da Universidade de São Paulo (ISSN 0103-0663).
期刊最新文献
Metodologias de identificação de marcas de mordidas O assessor: personagem central na publicação científica Prevalence of microorganisms in root canals of human deciduous teeth with necrotic pulp and chronic periapical lesions. Effect of plaque accumulation and salivary factors on enamel demineralization and plaque composition in situ. In vitro evaluation of human dental enamel surface roughness bleached with 35% carbamide peroxide and submitted to abrasive dentifrice brushing.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1