应用Epsilometer试验评价红霉素耐药化脓性链球菌对罗基他霉素(一种16元大环内酯类药物)的敏感性。

D Crotti, R Rossetti, P C Braga
{"title":"应用Epsilometer试验评价红霉素耐药化脓性链球菌对罗基他霉素(一种16元大环内酯类药物)的敏感性。","authors":"D Crotti,&nbsp;R Rossetti,&nbsp;P C Braga","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>Routine hospital screening of the resistance of Streptococcus pyogenes to macrolides is usually done using the erythromycin, clarithromycin or azithromycin disk diffusion technique. When a strain is found to be resistant to one of these macrolides, it is generally assumed to be resistant to the whole class. However this approach gives only partial qualitative information because S. pyogenes strains with inducible and M phenotype resistance are still susceptible to 16-membered ring macrolides such as rokitamycin. Seventy-four erythromycin-resistant (22 inducible and 52 M phenotype) strains of S. pyogenes were tested for their susceptibility to rokitamycin and clindamycin (control) by means of the agar disk diffusion test and the results were compared with those obtained using the Epsilometer test, a quantitative technique for measuring bacterial susceptibility and minimal inhibitory concentrations (MIC). Epsilometer testing of erythromycin in comparison with rokitamycin is useful for measuring the real degree of susceptibility of macrolide-resistant strains quickly and simply. This is important because strains with the same disk diffusion diameter do not necessarily have the same MIC, but a scattered distribution of susceptibility.</p>","PeriodicalId":11336,"journal":{"name":"Drugs under experimental and clinical research","volume":"30 1","pages":"17-26"},"PeriodicalIF":0.0000,"publicationDate":"2004-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Evaluation of the degree of susceptibility of Streptococcus pyogenes erythromycin-resistant strains to rokitamycin (a 16-membered macrolide) using the Epsilometer test.\",\"authors\":\"D Crotti,&nbsp;R Rossetti,&nbsp;P C Braga\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Routine hospital screening of the resistance of Streptococcus pyogenes to macrolides is usually done using the erythromycin, clarithromycin or azithromycin disk diffusion technique. When a strain is found to be resistant to one of these macrolides, it is generally assumed to be resistant to the whole class. However this approach gives only partial qualitative information because S. pyogenes strains with inducible and M phenotype resistance are still susceptible to 16-membered ring macrolides such as rokitamycin. Seventy-four erythromycin-resistant (22 inducible and 52 M phenotype) strains of S. pyogenes were tested for their susceptibility to rokitamycin and clindamycin (control) by means of the agar disk diffusion test and the results were compared with those obtained using the Epsilometer test, a quantitative technique for measuring bacterial susceptibility and minimal inhibitory concentrations (MIC). Epsilometer testing of erythromycin in comparison with rokitamycin is useful for measuring the real degree of susceptibility of macrolide-resistant strains quickly and simply. This is important because strains with the same disk diffusion diameter do not necessarily have the same MIC, but a scattered distribution of susceptibility.</p>\",\"PeriodicalId\":11336,\"journal\":{\"name\":\"Drugs under experimental and clinical research\",\"volume\":\"30 1\",\"pages\":\"17-26\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2004-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Drugs under experimental and clinical research\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Drugs under experimental and clinical research","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

医院常规化脓性链球菌对大环内酯类药物耐药筛查通常采用红霉素、克拉霉素或阿奇霉素盘片扩散技术。当发现一种菌株对其中一种大环内酯类具有耐药性时,一般认为它对整个类都具有耐药性。然而,这种方法只能提供部分定性信息,因为具有诱导型和M型抗性的化脓性葡萄球菌菌株仍然对16元环大环内酯类药物如罗基他霉素敏感。采用琼脂盘扩散法检测74株红霉素耐药菌株(22株诱导型,52株M型)对罗基他霉素和克林霉素(对照)的敏感性,并与Epsilometer试验(一种定量测定细菌敏感性和最小抑制浓度(MIC)的技术)进行比较。用Epsilometer检测红霉素与罗基他霉素的比较,可以快速、简便地测定大环内酯耐药菌株的真实药敏程度。这一点很重要,因为具有相同圆盘扩散直径的应变不一定具有相同的MIC,而是磁化率的分散分布。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Evaluation of the degree of susceptibility of Streptococcus pyogenes erythromycin-resistant strains to rokitamycin (a 16-membered macrolide) using the Epsilometer test.

Routine hospital screening of the resistance of Streptococcus pyogenes to macrolides is usually done using the erythromycin, clarithromycin or azithromycin disk diffusion technique. When a strain is found to be resistant to one of these macrolides, it is generally assumed to be resistant to the whole class. However this approach gives only partial qualitative information because S. pyogenes strains with inducible and M phenotype resistance are still susceptible to 16-membered ring macrolides such as rokitamycin. Seventy-four erythromycin-resistant (22 inducible and 52 M phenotype) strains of S. pyogenes were tested for their susceptibility to rokitamycin and clindamycin (control) by means of the agar disk diffusion test and the results were compared with those obtained using the Epsilometer test, a quantitative technique for measuring bacterial susceptibility and minimal inhibitory concentrations (MIC). Epsilometer testing of erythromycin in comparison with rokitamycin is useful for measuring the real degree of susceptibility of macrolide-resistant strains quickly and simply. This is important because strains with the same disk diffusion diameter do not necessarily have the same MIC, but a scattered distribution of susceptibility.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Oral acute and subchronic toxicity of D-004, a lipid extract from Roystonea regia fruits, in rats. Evaluation of carnitine, acetylcarnitine and isovalerylcarnitine on immune function and apoptosis. Pharmacokinetics of a new extended-release nifedipine formulation following a single oral dose, in human volunteers. Molecular mechanisms for vascular injury in the metabolic syndrome. Quercus suber cork extract displays a tensor and smoothing effect on human skin: an in vivo study.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1