心尖二维超声心动图显示左心室容积和射血分数。

Cardiovascular diseases Pub Date : 1981-09-01
Sidney K. Edelman, Dennis W. Rowe, Leonard W. Pechacek, Efrain Garcia
{"title":"心尖二维超声心动图显示左心室容积和射血分数。","authors":"Sidney K. Edelman,&nbsp;Dennis W. Rowe,&nbsp;Leonard W. Pechacek,&nbsp;Efrain Garcia","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>Two-dimensional echocardiographic data in orthogonal apical projections were used to calculate left ventricular ejection fraction and volumes in 18 patients, 10 of whom had asynergy. The left ventricular chamber was modeled as a stack of 20 elliptical discs in order to minimize errors associated with assumptions of regular geometry. Calculations were compared to data from biplane angiography and yielded correlation coefficients of 0.91 for ejection fraction and 0.90 for volumes. The technique significantly underestimated volumes; the average ventricular volume was 161 +/- 23 ml from cineangiography and 104 +/- 25 ml from echocardiography (p < 0.001). Since this technique utilizes the most readily obtained echocardiographic views and allows for variations in ventricular architecture, its potential utility in long-term, serial evaluation of cardiac function appears promising.</p>","PeriodicalId":84396,"journal":{"name":"Cardiovascular diseases","volume":"8 3","pages":"344-354"},"PeriodicalIF":0.0000,"publicationDate":"1981-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC287953/pdf/cardiodis00003-0047.pdf","citationCount":"0","resultStr":"{\"title\":\"Left ventricular volumes and ejection fraction derived from apical two-dimensional echocardiography.\",\"authors\":\"Sidney K. Edelman,&nbsp;Dennis W. Rowe,&nbsp;Leonard W. Pechacek,&nbsp;Efrain Garcia\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Two-dimensional echocardiographic data in orthogonal apical projections were used to calculate left ventricular ejection fraction and volumes in 18 patients, 10 of whom had asynergy. The left ventricular chamber was modeled as a stack of 20 elliptical discs in order to minimize errors associated with assumptions of regular geometry. Calculations were compared to data from biplane angiography and yielded correlation coefficients of 0.91 for ejection fraction and 0.90 for volumes. The technique significantly underestimated volumes; the average ventricular volume was 161 +/- 23 ml from cineangiography and 104 +/- 25 ml from echocardiography (p < 0.001). Since this technique utilizes the most readily obtained echocardiographic views and allows for variations in ventricular architecture, its potential utility in long-term, serial evaluation of cardiac function appears promising.</p>\",\"PeriodicalId\":84396,\"journal\":{\"name\":\"Cardiovascular diseases\",\"volume\":\"8 3\",\"pages\":\"344-354\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1981-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC287953/pdf/cardiodis00003-0047.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Cardiovascular diseases\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Cardiovascular diseases","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

采用正交心尖投影的二维超声心动图数据计算18例患者的左室射血分数和容积,其中10例为无能性。左心室被建模为20个椭圆盘的堆栈,以尽量减少与规则几何假设相关的误差。计算结果与双翼血管造影数据进行比较,得出射血分数的相关系数为0.91,体积的相关系数为0.90。该技术明显低估了体积;平均心室容积为161 +/- 23 ml,超声心动图为104 +/- 25 ml (p < 0.001)。由于这项技术利用了最容易获得的超声心动图视图,并允许心室结构的变化,因此它在长期、连续评估心功能方面的潜在效用似乎很有希望。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Left ventricular volumes and ejection fraction derived from apical two-dimensional echocardiography.

Two-dimensional echocardiographic data in orthogonal apical projections were used to calculate left ventricular ejection fraction and volumes in 18 patients, 10 of whom had asynergy. The left ventricular chamber was modeled as a stack of 20 elliptical discs in order to minimize errors associated with assumptions of regular geometry. Calculations were compared to data from biplane angiography and yielded correlation coefficients of 0.91 for ejection fraction and 0.90 for volumes. The technique significantly underestimated volumes; the average ventricular volume was 161 +/- 23 ml from cineangiography and 104 +/- 25 ml from echocardiography (p < 0.001). Since this technique utilizes the most readily obtained echocardiographic views and allows for variations in ventricular architecture, its potential utility in long-term, serial evaluation of cardiac function appears promising.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
PULMONARY VALVE ATRESIA WITH INTACT VENTRICULAR SEPTUM. Venous volume displacement plethysmography: Its diagnostic value in deep venous thrombosis as determined by receiver operator characteristic curves. Blood velocity measurement in human conjunctival vessels. Dextrocardia with situs inversus totalis: Cardiovascular surgery in three patients with concomitant coronary artery disease. Chronic traumatic popliteal arteriovenous fistula: Case report.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1