{"title":"一种用于校准被动采样器在低(ppbv)浓度下挥发性有机化合物的暴露系统。","authors":"X L Cao, C N Hewitt","doi":"10.1080/10473289.1994.10467324","DOIUrl":null,"url":null,"abstract":"<p><p>A recycling exposure system, which has characteristics of dynamic and static systems, has been designed and constructed for calibrating passive sampling tubes. This system is very easy to set up and maintain. Organic vapors inside the system are generated by syringe injection, and homogeneous vapors are circulated by a metal-bellows pump. The concentrations of light hydrocarbons (e.g., isoprene) may decrease slightly after circulating for longer than 10 hours; however, this system is very stable for C5-C8 hydrocarbons for at least eight hours. The system has been used successfully to calibrate Perkin-Elmer diffusion tubes packed with Chromosorb 106 for collecting benzene vapor at low exposure doses (< 70 ppmv x min). The entire system can be easily and effectively cleaned by circulating through a U-tube packed with activated carbon.</p>","PeriodicalId":79391,"journal":{"name":"Air & waste : journal of the Air & Waste Management Association","volume":"44 11","pages":"1299-302"},"PeriodicalIF":0.0000,"publicationDate":"1994-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1080/10473289.1994.10467324","citationCount":"4","resultStr":"{\"title\":\"An exposure system for the calibration of passive samplers to volatile organic compounds at low (ppbv) concentrations.\",\"authors\":\"X L Cao, C N Hewitt\",\"doi\":\"10.1080/10473289.1994.10467324\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>A recycling exposure system, which has characteristics of dynamic and static systems, has been designed and constructed for calibrating passive sampling tubes. This system is very easy to set up and maintain. Organic vapors inside the system are generated by syringe injection, and homogeneous vapors are circulated by a metal-bellows pump. The concentrations of light hydrocarbons (e.g., isoprene) may decrease slightly after circulating for longer than 10 hours; however, this system is very stable for C5-C8 hydrocarbons for at least eight hours. The system has been used successfully to calibrate Perkin-Elmer diffusion tubes packed with Chromosorb 106 for collecting benzene vapor at low exposure doses (< 70 ppmv x min). The entire system can be easily and effectively cleaned by circulating through a U-tube packed with activated carbon.</p>\",\"PeriodicalId\":79391,\"journal\":{\"name\":\"Air & waste : journal of the Air & Waste Management Association\",\"volume\":\"44 11\",\"pages\":\"1299-302\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1994-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1080/10473289.1994.10467324\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Air & waste : journal of the Air & Waste Management Association\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1080/10473289.1994.10467324\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Air & waste : journal of the Air & Waste Management Association","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1080/10473289.1994.10467324","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4
摘要
设计并构建了一种具有动态和静态特性的被动采样管校准循环暴露系统。这个系统很容易设置和维护。系统内部有机蒸汽由注射器注射产生,均质蒸汽由金属波纹管泵循环。轻烃(如异戊二烯)的浓度在循环超过10小时后可能略有下降;然而,该体系对C5-C8碳氢化合物来说是非常稳定的,至少可以维持8小时。该系统已成功用于校准装有Chromosorb 106的Perkin-Elmer扩散管,用于收集低暴露剂量(< 70 ppmv x min)的苯蒸气。整个系统可以很容易和有效地通过循环通过u型管填充活性炭清洁。
An exposure system for the calibration of passive samplers to volatile organic compounds at low (ppbv) concentrations.
A recycling exposure system, which has characteristics of dynamic and static systems, has been designed and constructed for calibrating passive sampling tubes. This system is very easy to set up and maintain. Organic vapors inside the system are generated by syringe injection, and homogeneous vapors are circulated by a metal-bellows pump. The concentrations of light hydrocarbons (e.g., isoprene) may decrease slightly after circulating for longer than 10 hours; however, this system is very stable for C5-C8 hydrocarbons for at least eight hours. The system has been used successfully to calibrate Perkin-Elmer diffusion tubes packed with Chromosorb 106 for collecting benzene vapor at low exposure doses (< 70 ppmv x min). The entire system can be easily and effectively cleaned by circulating through a U-tube packed with activated carbon.