笼子设计对动物室内空气中过敏原和内毒素的影响:用离子充电装置进行大容量测量。

James Platts-Mills, Natalie Custis, Alice Kenney, Amy Tsay, Martin Chapman, Sanford Feldman, Thomas Platts-Mills
{"title":"笼子设计对动物室内空气中过敏原和内毒素的影响:用离子充电装置进行大容量测量。","authors":"James Platts-Mills,&nbsp;Natalie Custis,&nbsp;Alice Kenney,&nbsp;Amy Tsay,&nbsp;Martin Chapman,&nbsp;Sanford Feldman,&nbsp;Thomas Platts-Mills","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>Respiratory symptoms related to both endotoxins and animal allergens continue to be an important cause of occupational disease for animal technicians and scientists working with rodents. Better sampling methods for airborne allergens and endotoxin are needed to help standardize compliance with federal occupational health regulations. Using an ion-charging device, we sampled 20 mouse rooms and four rat rooms at the University of Virginia, along with 43 domestic living rooms in houses in the Charlottesville area with at least one cat or dog. The use of filter tops on cages corresponds to a 50-fold reduction in mean levels of both airborne allergens (P < 0.001) and endotoxin (P < 0.001). The use of vented cages with filtered exhaust ports was associated with additional reductions. However, the mean airborne endotoxin level in all rooms using filter tops without a filtered exhaust port on the cages was significantly lower (P = 0.003) than the level in domestic living rooms. Our results for maximum airborne allergens or endotoxin are comparable with previous reports. However, the sensitivity of the technique allows an accurate assessment of low-level exposure, which makes it possible to evaluate the effect of cage designs. In addition, this approach allows direct comparison with results for airborne allergen and endotoxin in domestic homes. The results could allow a more consistent approach to the application of occupational health guidelines.</p>","PeriodicalId":80269,"journal":{"name":"Contemporary topics in laboratory animal science","volume":"44 2","pages":"12-6"},"PeriodicalIF":0.0000,"publicationDate":"2005-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"The effects of cage design on airborne allergens and endotoxin in animal rooms: high-volume measurements with an ion-charging device.\",\"authors\":\"James Platts-Mills,&nbsp;Natalie Custis,&nbsp;Alice Kenney,&nbsp;Amy Tsay,&nbsp;Martin Chapman,&nbsp;Sanford Feldman,&nbsp;Thomas Platts-Mills\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Respiratory symptoms related to both endotoxins and animal allergens continue to be an important cause of occupational disease for animal technicians and scientists working with rodents. Better sampling methods for airborne allergens and endotoxin are needed to help standardize compliance with federal occupational health regulations. Using an ion-charging device, we sampled 20 mouse rooms and four rat rooms at the University of Virginia, along with 43 domestic living rooms in houses in the Charlottesville area with at least one cat or dog. The use of filter tops on cages corresponds to a 50-fold reduction in mean levels of both airborne allergens (P < 0.001) and endotoxin (P < 0.001). The use of vented cages with filtered exhaust ports was associated with additional reductions. However, the mean airborne endotoxin level in all rooms using filter tops without a filtered exhaust port on the cages was significantly lower (P = 0.003) than the level in domestic living rooms. Our results for maximum airborne allergens or endotoxin are comparable with previous reports. However, the sensitivity of the technique allows an accurate assessment of low-level exposure, which makes it possible to evaluate the effect of cage designs. In addition, this approach allows direct comparison with results for airborne allergen and endotoxin in domestic homes. The results could allow a more consistent approach to the application of occupational health guidelines.</p>\",\"PeriodicalId\":80269,\"journal\":{\"name\":\"Contemporary topics in laboratory animal science\",\"volume\":\"44 2\",\"pages\":\"12-6\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2005-03-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Contemporary topics in laboratory animal science\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Contemporary topics in laboratory animal science","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

与内毒素和动物过敏原相关的呼吸道症状仍然是与啮齿动物工作的动物技术人员和科学家的职业病的重要原因。需要更好的空气中过敏原和内毒素的采样方法,以帮助标准化遵守联邦职业健康法规。我们使用一种离子充电装置,对弗吉尼亚大学(University of Virginia)的20个老鼠房间和4个老鼠房间,以及夏洛茨维尔(Charlottesville)地区至少有一只猫或狗的43个家庭客厅进行了取样。在笼子上使用过滤盖可使空气中过敏原(P < 0.001)和内毒素(P < 0.001)的平均水平降低50倍。使用带有过滤排气口的通风笼可进一步减少废气排放。然而,在没有过滤排气口的笼子顶部使用过滤器的房间中,空气中平均内毒素水平显著低于家庭客厅(P = 0.003)。我们对空气中最大过敏原或内毒素的结果与以前的报告相当。然而,该技术的灵敏度允许对低水平暴露进行准确评估,这使得评估笼设计的效果成为可能。此外,这种方法可以直接与空气中过敏原和内毒素的结果进行比较。研究结果可以使职业健康指导方针的应用更加一致。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
The effects of cage design on airborne allergens and endotoxin in animal rooms: high-volume measurements with an ion-charging device.

Respiratory symptoms related to both endotoxins and animal allergens continue to be an important cause of occupational disease for animal technicians and scientists working with rodents. Better sampling methods for airborne allergens and endotoxin are needed to help standardize compliance with federal occupational health regulations. Using an ion-charging device, we sampled 20 mouse rooms and four rat rooms at the University of Virginia, along with 43 domestic living rooms in houses in the Charlottesville area with at least one cat or dog. The use of filter tops on cages corresponds to a 50-fold reduction in mean levels of both airborne allergens (P < 0.001) and endotoxin (P < 0.001). The use of vented cages with filtered exhaust ports was associated with additional reductions. However, the mean airborne endotoxin level in all rooms using filter tops without a filtered exhaust port on the cages was significantly lower (P = 0.003) than the level in domestic living rooms. Our results for maximum airborne allergens or endotoxin are comparable with previous reports. However, the sensitivity of the technique allows an accurate assessment of low-level exposure, which makes it possible to evaluate the effect of cage designs. In addition, this approach allows direct comparison with results for airborne allergen and endotoxin in domestic homes. The results could allow a more consistent approach to the application of occupational health guidelines.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Effects of altered enclosure size and substrates on squirrel monkey (Saimiri sciureus sciureus) behavior. Intraperitoneal administration of an iodine-based contrast agent to improve abdominal micro-computed tomography imaging in mice. Transfusion via the carotid artery in the hamster. Thyroparathyroidectomy procedures and thyroxine levels in the chinchilla. Lack of correlation of vaginal impedance measurements with hormone levels in the rat.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1