{"title":"[用于ecg门控CT的新型搏动冠状动脉幻像的设计与研制及其实验特性]。","authors":"Yun Shen,&nbsp;Munekuni Sato,&nbsp;Fumiko Kimura,&nbsp;Masahiro Jinzaki,&nbsp;Jun Horiguchi,&nbsp;Katsuhide Ito,&nbsp;Sachio Kuribayashi","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>The optimal pulsating cardiac phantom is an important tool for the evaluation of cardiac images and cardiac applications on ECG-gated MDCT. The purpose of this study was to demonstrate the design and fabrication of the pulsating cardiac coronary phantom. The newly developed pulsating cardiac coronary phantom has the following five key advantages: 1) a driver component that uses only one servomotor to move the phantom in three dimensions (X, Y, and Z directions) with 16 presets of different heart types (heartbeat: 0-120 bpm; ejection fraction: 0-90%); 2) versatile pumping and filling phases to simulate a real heart in a cardiac cycle can be incorporated into the driver sequence including shift of patient heartbeat or irregular pulse (maximum: 200 different heart waves in one scan); 3) a cardiac coronary component constituted of an acrylic/silicon/rubber tube (2-6 mm inner diameter) with stent/in-stent restenosis/stenosis/soft plaque/calcification parts and maximum 16 coronary arteries that can be attached to the phantom in the same scan; 4) the complete phantom can be submerged in a tank to simulate the heart and its surrounding tissues; 5) ECG gating can be from interior trigger and exterior trigger. It has been confirmed that the developed pulsating cardiac phantom is very useful to quantitatively assess imaging of the heart and coronary arteries during phantom experiments.</p>","PeriodicalId":19251,"journal":{"name":"Nihon Igaku Hoshasen Gakkai zasshi. Nippon acta radiologica","volume":"65 3","pages":"224-32"},"PeriodicalIF":0.0000,"publicationDate":"2005-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"[Design and development of a new pulsating cardiac coronary phantom for ECG-gated CT and its experimental characteristics].\",\"authors\":\"Yun Shen,&nbsp;Munekuni Sato,&nbsp;Fumiko Kimura,&nbsp;Masahiro Jinzaki,&nbsp;Jun Horiguchi,&nbsp;Katsuhide Ito,&nbsp;Sachio Kuribayashi\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The optimal pulsating cardiac phantom is an important tool for the evaluation of cardiac images and cardiac applications on ECG-gated MDCT. The purpose of this study was to demonstrate the design and fabrication of the pulsating cardiac coronary phantom. The newly developed pulsating cardiac coronary phantom has the following five key advantages: 1) a driver component that uses only one servomotor to move the phantom in three dimensions (X, Y, and Z directions) with 16 presets of different heart types (heartbeat: 0-120 bpm; ejection fraction: 0-90%); 2) versatile pumping and filling phases to simulate a real heart in a cardiac cycle can be incorporated into the driver sequence including shift of patient heartbeat or irregular pulse (maximum: 200 different heart waves in one scan); 3) a cardiac coronary component constituted of an acrylic/silicon/rubber tube (2-6 mm inner diameter) with stent/in-stent restenosis/stenosis/soft plaque/calcification parts and maximum 16 coronary arteries that can be attached to the phantom in the same scan; 4) the complete phantom can be submerged in a tank to simulate the heart and its surrounding tissues; 5) ECG gating can be from interior trigger and exterior trigger. It has been confirmed that the developed pulsating cardiac phantom is very useful to quantitatively assess imaging of the heart and coronary arteries during phantom experiments.</p>\",\"PeriodicalId\":19251,\"journal\":{\"name\":\"Nihon Igaku Hoshasen Gakkai zasshi. Nippon acta radiologica\",\"volume\":\"65 3\",\"pages\":\"224-32\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2005-07-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Nihon Igaku Hoshasen Gakkai zasshi. Nippon acta radiologica\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Nihon Igaku Hoshasen Gakkai zasshi. Nippon acta radiologica","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

最佳搏动虚影是心电图门控MDCT评价心脏图像和心脏应用的重要工具。本研究的目的是演示脉动心脏冠状动脉幻像的设计和制造。新开发的脉动心脏冠状动脉幻影具有以下五个关键优势:1)驱动组件仅使用一个伺服电机在三维(X, Y和Z方向)上移动幻影,并预置16种不同的心脏类型(心跳:0-120 bpm;喷射分数:0-90%);2)在心脏周期中模拟真实心脏的多用途泵送和填充阶段可纳入驱动序列,包括患者心跳或不规则脉搏的移位(一次扫描最多可达200种不同的心波);3)由丙烯酸/硅/橡胶管(内径2- 6mm)组成的心脏冠状动脉组件,具有支架内/支架内再狭窄/狭窄/软斑块/钙化部分和最多16条冠状动脉,可在同一次扫描中附着于幻肢;4)将完整的假体浸泡在水箱中模拟心脏及其周围组织;5)心电门控分为内触发和外触发两种。研究证实,发展的搏动心脏幻像在幻像实验中对心脏和冠状动脉成像的定量评估是非常有用的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
[Design and development of a new pulsating cardiac coronary phantom for ECG-gated CT and its experimental characteristics].

The optimal pulsating cardiac phantom is an important tool for the evaluation of cardiac images and cardiac applications on ECG-gated MDCT. The purpose of this study was to demonstrate the design and fabrication of the pulsating cardiac coronary phantom. The newly developed pulsating cardiac coronary phantom has the following five key advantages: 1) a driver component that uses only one servomotor to move the phantom in three dimensions (X, Y, and Z directions) with 16 presets of different heart types (heartbeat: 0-120 bpm; ejection fraction: 0-90%); 2) versatile pumping and filling phases to simulate a real heart in a cardiac cycle can be incorporated into the driver sequence including shift of patient heartbeat or irregular pulse (maximum: 200 different heart waves in one scan); 3) a cardiac coronary component constituted of an acrylic/silicon/rubber tube (2-6 mm inner diameter) with stent/in-stent restenosis/stenosis/soft plaque/calcification parts and maximum 16 coronary arteries that can be attached to the phantom in the same scan; 4) the complete phantom can be submerged in a tank to simulate the heart and its surrounding tissues; 5) ECG gating can be from interior trigger and exterior trigger. It has been confirmed that the developed pulsating cardiac phantom is very useful to quantitatively assess imaging of the heart and coronary arteries during phantom experiments.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
[Abstracts of the 45th Autumn Meeting of the Japanese Radiological Society. October 29-31, 2009. Wakayama, Japan]. [Abstracts of the 68th Annual Meeting of the Japanese Radiological Society. April 16-19, 2009. Yokohama, Japan]. [The 44th Autumn Meeting of the Japanese Radiological Society. Fukushima, Japan. October 22-24, 2008. Abstracts]. [The 67th Annual Meeting of the Japanese Radiological Society. Yokohama, Japan. April 4-6, 2008. Abstracts]. [The 43rd autumn meeting of the Japan Radiological Society. Nagoya, Japan. October 25-27, 2007. Abstracts].
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1