微计算机断层扫描评估热成型后对准器厚度和间隙宽度的总体趋势,涉及六种商业透明对准器:一项体外研究。

IF 1.9 3区 医学 Q1 Dentistry Korean Journal of Orthodontics Pub Date : 2021-03-25 DOI:10.4041/kjod.2021.51.2.135
Mario Palone, Mattia Longo, Niki Arveda, Michele Nacucchi, Fabio De Pascalis, Giorgio Alfredo Spedicato, Giuseppe Siciliani, Luca Lombardo
{"title":"微计算机断层扫描评估热成型后对准器厚度和间隙宽度的总体趋势,涉及六种商业透明对准器:一项体外研究。","authors":"Mario Palone,&nbsp;Mattia Longo,&nbsp;Niki Arveda,&nbsp;Michele Nacucchi,&nbsp;Fabio De Pascalis,&nbsp;Giorgio Alfredo Spedicato,&nbsp;Giuseppe Siciliani,&nbsp;Luca Lombardo","doi":"10.4041/kjod.2021.51.2.135","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>To assess the effects of thermoforming on aligner thickness and gap width in six aligner systems with the same nominal thickness.</p><p><strong>Methods: </strong>Six passive upper aligners of different brands were adapted to a single printed cast. Each sample was evaluated with high-resolution micro-computed tomography. To investigate aligner thickness and gap width, two-dimensional (2D) analysis was conducted assessing the effects of the following variables: tooth type (central incisor, canine, and first molar), 2D reference points, and aligner type. Data were analyzed and compared using analysis of variance and Tukey's post-hoc tests (<i>p</i> < 0.05).</p><p><strong>Results: </strong>Tooth type, dental region, and aligner type affected both the gap width and aligner thickness. The aligner thickness remained moderately stable across the arch only in the F22.</p><p><strong>Conclusions: </strong>All thermoformed samples displayed smaller aligner thickness and gap width at anterior teeth and both gingival and coronal centers than at posterior teeth and occlusal surfaces.</p>","PeriodicalId":49934,"journal":{"name":"Korean Journal of Orthodontics","volume":null,"pages":null},"PeriodicalIF":1.9000,"publicationDate":"2021-03-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/47/f7/kjod-51-2-135.PMC7940810.pdf","citationCount":"11","resultStr":"{\"title\":\"Micro-computed tomography evaluation of general trends in aligner thickness and gap width after thermoforming procedures involving six commercial clear aligners: An <i>in vitro</i> study.\",\"authors\":\"Mario Palone,&nbsp;Mattia Longo,&nbsp;Niki Arveda,&nbsp;Michele Nacucchi,&nbsp;Fabio De Pascalis,&nbsp;Giorgio Alfredo Spedicato,&nbsp;Giuseppe Siciliani,&nbsp;Luca Lombardo\",\"doi\":\"10.4041/kjod.2021.51.2.135\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objective: </strong>To assess the effects of thermoforming on aligner thickness and gap width in six aligner systems with the same nominal thickness.</p><p><strong>Methods: </strong>Six passive upper aligners of different brands were adapted to a single printed cast. Each sample was evaluated with high-resolution micro-computed tomography. To investigate aligner thickness and gap width, two-dimensional (2D) analysis was conducted assessing the effects of the following variables: tooth type (central incisor, canine, and first molar), 2D reference points, and aligner type. Data were analyzed and compared using analysis of variance and Tukey's post-hoc tests (<i>p</i> < 0.05).</p><p><strong>Results: </strong>Tooth type, dental region, and aligner type affected both the gap width and aligner thickness. The aligner thickness remained moderately stable across the arch only in the F22.</p><p><strong>Conclusions: </strong>All thermoformed samples displayed smaller aligner thickness and gap width at anterior teeth and both gingival and coronal centers than at posterior teeth and occlusal surfaces.</p>\",\"PeriodicalId\":49934,\"journal\":{\"name\":\"Korean Journal of Orthodontics\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.9000,\"publicationDate\":\"2021-03-25\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/47/f7/kjod-51-2-135.PMC7940810.pdf\",\"citationCount\":\"11\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Korean Journal of Orthodontics\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.4041/kjod.2021.51.2.135\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"Dentistry\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Korean Journal of Orthodontics","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.4041/kjod.2021.51.2.135","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"Dentistry","Score":null,"Total":0}
引用次数: 11

摘要

目的:评估热成型对六种相同标称厚度的矫直器厚度和间隙宽度的影响。方法:采用六种不同牌号的被动上牙矫直器,分别应用于一种印刷铸造。每个样本都用高分辨率显微计算机断层扫描进行评估。为了研究矫正器的厚度和间隙宽度,进行了二维(2D)分析,评估了以下变量的影响:牙齿类型(中切牙、犬齿和第一磨牙)、二维参考点和矫正器类型。采用方差分析和Tukey事后检验对资料进行分析比较(p < 0.05)。结果:牙型、牙区、矫正器类型对牙间隙宽度和矫正器厚度均有影响。矫正器厚度仅在F22保持适度稳定。结论:所有热成型样品在前牙、牙龈和冠状中心的对准器厚度和间隙宽度均小于后牙和咬合面。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Micro-computed tomography evaluation of general trends in aligner thickness and gap width after thermoforming procedures involving six commercial clear aligners: An in vitro study.

Objective: To assess the effects of thermoforming on aligner thickness and gap width in six aligner systems with the same nominal thickness.

Methods: Six passive upper aligners of different brands were adapted to a single printed cast. Each sample was evaluated with high-resolution micro-computed tomography. To investigate aligner thickness and gap width, two-dimensional (2D) analysis was conducted assessing the effects of the following variables: tooth type (central incisor, canine, and first molar), 2D reference points, and aligner type. Data were analyzed and compared using analysis of variance and Tukey's post-hoc tests (p < 0.05).

Results: Tooth type, dental region, and aligner type affected both the gap width and aligner thickness. The aligner thickness remained moderately stable across the arch only in the F22.

Conclusions: All thermoformed samples displayed smaller aligner thickness and gap width at anterior teeth and both gingival and coronal centers than at posterior teeth and occlusal surfaces.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Korean Journal of Orthodontics
Korean Journal of Orthodontics Dentistry-Orthodontics
CiteScore
2.60
自引率
10.50%
发文量
48
审稿时长
3 months
期刊介绍: The Korean Journal of Orthodontics (KJO) is an international, open access, peer reviewed journal published in January, March, May, July, September, and November each year. It was first launched in 1970 and, as the official scientific publication of Korean Association of Orthodontists, KJO aims to publish high quality clinical and scientific original research papers in all areas related to orthodontics and dentofacial orthopedics. Specifically, its interest focuses on evidence-based investigations of contemporary diagnostic procedures and treatment techniques, expanding to significant clinical reports of diverse treatment approaches. The scope of KJO covers all areas of orthodontics and dentofacial orthopedics including successful diagnostic procedures and treatment planning, growth and development of the face and its clinical implications, appliance designs, biomechanics, TMJ disorders and adult treatment. Specifically, its latest interest focuses on skeletal anchorage devices, orthodontic appliance and biomaterials, 3 dimensional imaging techniques utilized for dentofacial diagnosis and treatment planning, and orthognathic surgery to correct skeletal disharmony in association of orthodontic treatment.
期刊最新文献
Clinical expression of programmed maxillary buccal expansion and buccolingual crown inclination with Invisalign EX30 and SmartTrack aligners and the effect of 1-week vs. 2-week aligner change regimes: A retrospective cohort study. Orthodontic treatment in a patient with Moebius syndrome: A case report. Clinical effects of different prescriptions on the inclination of maxillary and mandibular incisors by using passive self-ligating brackets. Enhancement of bioactivity and osseointegration in Ti-6Al-4V orthodontic mini-screws coated with calcium phosphate on the TiO2 nanotube layer. Crown-root angulations of the maxillary anterior teeth according to malocclusions: A cone-beam computed tomography study in Korean population.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1