喀麦隆西北部巴门达地区健康成人血液学参考值的建立

IF 2.2 Q3 HEMATOLOGY Anemia Pub Date : 2021-02-24 eCollection Date: 2021-01-01 DOI:10.1155/2021/6690926
Nfor Omarine Nlinwe, Yunika Larissa Kumenyuy, Che Precious Funwi
{"title":"喀麦隆西北部巴门达地区健康成人血液学参考值的建立","authors":"Nfor Omarine Nlinwe,&nbsp;Yunika Larissa Kumenyuy,&nbsp;Che Precious Funwi","doi":"10.1155/2021/6690926","DOIUrl":null,"url":null,"abstract":"<p><p>The use of the reference range of values of a laboratory test is highly significant in diagnostic accuracy. However, race and ethnic variations may affect the safe use of reference ranges from a different setting/population. Because the establishment of reference ranges for the Cameroonian population will possibly improve the quality of health care, this study was designed to establish hematological reference ranges among healthy adults in Bamenda, North West region of Cameroon. This was a cross-sectional study carried out within the period of five months from February 2020 to June 2020, at the Bamenda Regional Hospital. A total of 350 (139 females and 211 males) study participants who met the inclusion criteria were included in the study. The Urit 3300 autoanalyzer (Urit Medical Electronic (Group) Co., Ltd, Guilin, China) was used to analyze the hematological parameters. The general health questionnaire for donors, for verification of reference range study and laboratory tests, was used for data collection. Descriptive statistics were used to calculate reference ranges, means, and medians at 95% confidence intervals. Maximum and minimum reference ranges were computed at 97.5th and 2.5th percentiles. The nonparametric test (Mann-Whitney test) was used to determine the significance of the difference in hematological values between the male and female groups. Three (MID%, LYM#, and MID#) out of the 19 hematological parameters were verified, while sixteen (WBC, LYM%, GRAN%, GRAN#, RBC, HGB, HCT%, MCV, MCH, MCHC, RDW_CV, RDW_SD, PLT, MPV, PDW, and PCT%) were established. The currently used reference intervals do not represent the population of the North West region. Therefore, other regional hospitals in Cameroon should establish reference intervals applicable to their respective regions.</p>","PeriodicalId":46055,"journal":{"name":"Anemia","volume":"2021 ","pages":"6690926"},"PeriodicalIF":2.2000,"publicationDate":"2021-02-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7932772/pdf/","citationCount":"6","resultStr":"{\"title\":\"Establishment of Hematological Reference Values among Healthy Adults in Bamenda, North West Region of Cameroon.\",\"authors\":\"Nfor Omarine Nlinwe,&nbsp;Yunika Larissa Kumenyuy,&nbsp;Che Precious Funwi\",\"doi\":\"10.1155/2021/6690926\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The use of the reference range of values of a laboratory test is highly significant in diagnostic accuracy. However, race and ethnic variations may affect the safe use of reference ranges from a different setting/population. Because the establishment of reference ranges for the Cameroonian population will possibly improve the quality of health care, this study was designed to establish hematological reference ranges among healthy adults in Bamenda, North West region of Cameroon. This was a cross-sectional study carried out within the period of five months from February 2020 to June 2020, at the Bamenda Regional Hospital. A total of 350 (139 females and 211 males) study participants who met the inclusion criteria were included in the study. The Urit 3300 autoanalyzer (Urit Medical Electronic (Group) Co., Ltd, Guilin, China) was used to analyze the hematological parameters. The general health questionnaire for donors, for verification of reference range study and laboratory tests, was used for data collection. Descriptive statistics were used to calculate reference ranges, means, and medians at 95% confidence intervals. Maximum and minimum reference ranges were computed at 97.5th and 2.5th percentiles. The nonparametric test (Mann-Whitney test) was used to determine the significance of the difference in hematological values between the male and female groups. Three (MID%, LYM#, and MID#) out of the 19 hematological parameters were verified, while sixteen (WBC, LYM%, GRAN%, GRAN#, RBC, HGB, HCT%, MCV, MCH, MCHC, RDW_CV, RDW_SD, PLT, MPV, PDW, and PCT%) were established. The currently used reference intervals do not represent the population of the North West region. Therefore, other regional hospitals in Cameroon should establish reference intervals applicable to their respective regions.</p>\",\"PeriodicalId\":46055,\"journal\":{\"name\":\"Anemia\",\"volume\":\"2021 \",\"pages\":\"6690926\"},\"PeriodicalIF\":2.2000,\"publicationDate\":\"2021-02-24\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7932772/pdf/\",\"citationCount\":\"6\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Anemia\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1155/2021/6690926\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2021/1/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"Q3\",\"JCRName\":\"HEMATOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Anemia","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1155/2021/6690926","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2021/1/1 0:00:00","PubModel":"eCollection","JCR":"Q3","JCRName":"HEMATOLOGY","Score":null,"Total":0}
引用次数: 6

摘要

使用实验室测试值的参考范围对诊断准确性非常重要。然而,种族和民族差异可能会影响来自不同环境/人群的参考范围的安全使用。由于建立喀麦隆人口参考范围可能会提高卫生保健质量,本研究旨在建立喀麦隆西北部巴门达地区健康成年人的血液学参考范围。这是一项横断面研究,于2020年2月至2020年6月的五个月内在巴门达地区医院进行。共有350名(139名女性和211名男性)符合纳入标准的研究参与者被纳入研究。使用中国桂林优利特医疗电子(集团)有限公司的Urit 3300自动分析仪分析血液学参数。数据收集使用了捐助者一般健康调查表,以核实参考范围研究和实验室测试。描述性统计用于计算95%置信区间的参考范围、平均值和中位数。最大和最小参考范围分别在97.5和2.5个百分位计算。采用非参数检验(Mann-Whitney检验)确定男女两组血液学指标差异的显著性。对19项血液学参数中的3项(MID%、LYM#、MID#)进行了验证,同时建立了16项(WBC、LYM%、GRAN%、GRAN#、RBC、HGB、HCT%、MCV、MCH、MCHC、RDW_CV、RDW_SD、PLT、MPV、PDW、PCT%)。目前使用的参考区间不能代表西北地区的人口。因此,喀麦隆其他地区医院应建立适用于各自地区的参考区间。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Establishment of Hematological Reference Values among Healthy Adults in Bamenda, North West Region of Cameroon.

The use of the reference range of values of a laboratory test is highly significant in diagnostic accuracy. However, race and ethnic variations may affect the safe use of reference ranges from a different setting/population. Because the establishment of reference ranges for the Cameroonian population will possibly improve the quality of health care, this study was designed to establish hematological reference ranges among healthy adults in Bamenda, North West region of Cameroon. This was a cross-sectional study carried out within the period of five months from February 2020 to June 2020, at the Bamenda Regional Hospital. A total of 350 (139 females and 211 males) study participants who met the inclusion criteria were included in the study. The Urit 3300 autoanalyzer (Urit Medical Electronic (Group) Co., Ltd, Guilin, China) was used to analyze the hematological parameters. The general health questionnaire for donors, for verification of reference range study and laboratory tests, was used for data collection. Descriptive statistics were used to calculate reference ranges, means, and medians at 95% confidence intervals. Maximum and minimum reference ranges were computed at 97.5th and 2.5th percentiles. The nonparametric test (Mann-Whitney test) was used to determine the significance of the difference in hematological values between the male and female groups. Three (MID%, LYM#, and MID#) out of the 19 hematological parameters were verified, while sixteen (WBC, LYM%, GRAN%, GRAN#, RBC, HGB, HCT%, MCV, MCH, MCHC, RDW_CV, RDW_SD, PLT, MPV, PDW, and PCT%) were established. The currently used reference intervals do not represent the population of the North West region. Therefore, other regional hospitals in Cameroon should establish reference intervals applicable to their respective regions.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Anemia
Anemia HEMATOLOGY-
CiteScore
4.80
自引率
3.40%
发文量
11
审稿时长
18 weeks
期刊介绍: Anemia is a peer-reviewed, Open Access journal that publishes original research articles, review articles, and clinical studies on all types of anemia. Articles focusing on patient care, health systems, epidemiology, and animal models will be considered, among other relevant topics. Affecting roughly one third of the world’s population, anemia is a major public health concern. The journal aims to facilitate the exchange of research addressing global health and mortality relating to anemia and associated diseases.
期刊最新文献
Sickle Cell Anemia Screening in Newborns and Analysis of Haplotypes in Patients from Santiago Island, Cape Verde. Detection of Asymptomatic Sickle Cell Hemoglobin Carriers and Fetal Hemoglobin Regulating Genetic Variants in African Descendants from Oaxaca, Mexico. Gut Microbiota: Potential Therapeutic Target for Sickle Cell Disease Pain and Complications. Exploring Factors Associated with Quality of Life in Caregivers of Children and Adolescents with Sickle Cell Disease and HIV: A Comparative Analysis. Prevalence of Iron Deficiency, Anemia, and Associated Factors in a Blood Donor Population in Brazzaville, Congo.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1