用实时生物传感器定量flag标记融合蛋白的通用方法

Christa Mersich, Alois Jungbauer
{"title":"用实时生物传感器定量flag标记融合蛋白的通用方法","authors":"Christa Mersich,&nbsp;Alois Jungbauer","doi":"10.1016/j.jbbm.2007.01.004","DOIUrl":null,"url":null,"abstract":"<div><p>Availability of rapid quantitative protein-expression analysis is often the bottleneck in high throughput screening applications. A real time biosensor was employed to establish a quantitative assay for FLAG fusion proteins using FLAG-tagged bacterial alkaline phosphatase as standard. A range of FLAG-tagged bacterial alkaline phosphatase concentrations were injected over the anti-FLAG M2 antibody surface of the biosensor and used as standards to determine the concentration of different FLAG-tagged proteins with a molecular mass of 18.1 kDa respectively 49.3 kDa from yeast culture supernatants. The M2 immobilized chip was found to retain binding capacity following regeneration for at least 120 cycles. This real time biosensor method allows the quantitation of proteins from culture supernatants using a calibration curve obtained with a different protein. Further benefits include the short assay time of approximately 5 min, the small amount of sample required (35 μl per injection) and the ability to monitor the binding event in real time.</p></div>","PeriodicalId":15257,"journal":{"name":"Journal of biochemical and biophysical methods","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2007-06-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/j.jbbm.2007.01.004","citationCount":"10","resultStr":"{\"title\":\"Generic method for quantification of FLAG-tagged fusion proteins by a real time biosensor\",\"authors\":\"Christa Mersich,&nbsp;Alois Jungbauer\",\"doi\":\"10.1016/j.jbbm.2007.01.004\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>Availability of rapid quantitative protein-expression analysis is often the bottleneck in high throughput screening applications. A real time biosensor was employed to establish a quantitative assay for FLAG fusion proteins using FLAG-tagged bacterial alkaline phosphatase as standard. A range of FLAG-tagged bacterial alkaline phosphatase concentrations were injected over the anti-FLAG M2 antibody surface of the biosensor and used as standards to determine the concentration of different FLAG-tagged proteins with a molecular mass of 18.1 kDa respectively 49.3 kDa from yeast culture supernatants. The M2 immobilized chip was found to retain binding capacity following regeneration for at least 120 cycles. This real time biosensor method allows the quantitation of proteins from culture supernatants using a calibration curve obtained with a different protein. Further benefits include the short assay time of approximately 5 min, the small amount of sample required (35 μl per injection) and the ability to monitor the binding event in real time.</p></div>\",\"PeriodicalId\":15257,\"journal\":{\"name\":\"Journal of biochemical and biophysical methods\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2007-06-10\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1016/j.jbbm.2007.01.004\",\"citationCount\":\"10\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of biochemical and biophysical methods\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S0165022X07000048\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of biochemical and biophysical methods","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0165022X07000048","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 10

摘要

快速定量蛋白表达分析的可用性往往是高通量筛选应用的瓶颈。采用实时生物传感器,以FLAG标记的细菌碱性磷酸酶为标准,建立了FLAG融合蛋白的定量检测方法。在生物传感器的抗flag M2抗体表面注射一系列flag标记的细菌碱性磷酸酶浓度作为标准,测定酵母培养上清中不同flag标记蛋白的浓度,这些蛋白的分子量分别为18.1 kDa和49.3 kDa。发现M2固定芯片在再生至少120次循环后仍保持结合能力。这种实时生物传感器方法允许使用不同蛋白质获得的校准曲线从培养上清中定量蛋白质。进一步的好处包括检测时间短,约为5分钟,所需样品量少(每次注射35 μl),并且能够实时监测结合事件。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Generic method for quantification of FLAG-tagged fusion proteins by a real time biosensor

Availability of rapid quantitative protein-expression analysis is often the bottleneck in high throughput screening applications. A real time biosensor was employed to establish a quantitative assay for FLAG fusion proteins using FLAG-tagged bacterial alkaline phosphatase as standard. A range of FLAG-tagged bacterial alkaline phosphatase concentrations were injected over the anti-FLAG M2 antibody surface of the biosensor and used as standards to determine the concentration of different FLAG-tagged proteins with a molecular mass of 18.1 kDa respectively 49.3 kDa from yeast culture supernatants. The M2 immobilized chip was found to retain binding capacity following regeneration for at least 120 cycles. This real time biosensor method allows the quantitation of proteins from culture supernatants using a calibration curve obtained with a different protein. Further benefits include the short assay time of approximately 5 min, the small amount of sample required (35 μl per injection) and the ability to monitor the binding event in real time.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Editorial Board Fluorescent method for detection of cleaved collagens using O-phthaldialdehyde (OPA) A rapid and non leaky way for preparation of the sharp intracellular recording microelectrodes Quantification of penicillin G during labor and delivery by capillary electrophoresis Dispensing an enzyme-conjugated solution into an ELISA plate by adapting ink-jet printers
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1