O Driemel, E R Carlson, U Müller-Richter, A Moralis, S Lienhard, S Wagener, T E Reichert
{"title":"消融肿瘤手术中用于临时髁突重建的新型髁头系统。","authors":"O Driemel, E R Carlson, U Müller-Richter, A Moralis, S Lienhard, S Wagener, T E Reichert","doi":"10.1007/s10006-007-0062-8","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Based on own retrospective studies a condylar head add-on system for immediate, temporary reconstruction in patients undergoing ablative surgery requiring the removal of the manibular condyle has been developed in cooperation with the Department of Oral and Maxillofacial Surgery of the University of Tennessee, USA, and the Association for the Study of Internal Fixation (AO/ASIF).</p><p><strong>Purpose: </strong>The design of the new condylar head add-on system and its use in an anatomical dissection study on a human cadaver are introduced and discussed. DESIGN AND FIRST EXPERIENCES: The condylar replacement is made of commercial pure titanium and is conceived as an add-on system. It consists of a reconstruction plate (2.4 Uni-LOCK-System) und an adaptable condylar head that can be fitted on either side. The offset of the condylar head in a medial direction allows anatomically correct positioning of the implant. The slanted oval head shall provide a large contact area while maintaining function of the mandibular joint. The height-adjustable positioning of the condylar head add-on with four different fixations plates facilitates an intraoperative vertical correction of the condylar head without necessary bending of a new reconstruction plate. A condylar head add-on used on both sides and combined with the frequently used 2.4 Uni-LOCK-plate benefits from reduced storekeeping and turns out to be advantageous from an economic point of view.</p><p><strong>Perspective: </strong>An international, prospective multi-center study evaluating the intraoperative applicability of the new condylar head add-on system and its functional as well as aesthetic results during the first two postoperative years has started in September 2006.</p>","PeriodicalId":79515,"journal":{"name":"Mund-, Kiefer- und Gesichtschirurgie : MKG","volume":"11 4","pages":"193-9"},"PeriodicalIF":0.0000,"publicationDate":"2007-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1007/s10006-007-0062-8","citationCount":"5","resultStr":"{\"title\":\"[New condylar head system for temporary condylar reconstruction in ablative tumour surgery].\",\"authors\":\"O Driemel, E R Carlson, U Müller-Richter, A Moralis, S Lienhard, S Wagener, T E Reichert\",\"doi\":\"10.1007/s10006-007-0062-8\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Based on own retrospective studies a condylar head add-on system for immediate, temporary reconstruction in patients undergoing ablative surgery requiring the removal of the manibular condyle has been developed in cooperation with the Department of Oral and Maxillofacial Surgery of the University of Tennessee, USA, and the Association for the Study of Internal Fixation (AO/ASIF).</p><p><strong>Purpose: </strong>The design of the new condylar head add-on system and its use in an anatomical dissection study on a human cadaver are introduced and discussed. DESIGN AND FIRST EXPERIENCES: The condylar replacement is made of commercial pure titanium and is conceived as an add-on system. It consists of a reconstruction plate (2.4 Uni-LOCK-System) und an adaptable condylar head that can be fitted on either side. The offset of the condylar head in a medial direction allows anatomically correct positioning of the implant. The slanted oval head shall provide a large contact area while maintaining function of the mandibular joint. The height-adjustable positioning of the condylar head add-on with four different fixations plates facilitates an intraoperative vertical correction of the condylar head without necessary bending of a new reconstruction plate. A condylar head add-on used on both sides and combined with the frequently used 2.4 Uni-LOCK-plate benefits from reduced storekeeping and turns out to be advantageous from an economic point of view.</p><p><strong>Perspective: </strong>An international, prospective multi-center study evaluating the intraoperative applicability of the new condylar head add-on system and its functional as well as aesthetic results during the first two postoperative years has started in September 2006.</p>\",\"PeriodicalId\":79515,\"journal\":{\"name\":\"Mund-, Kiefer- und Gesichtschirurgie : MKG\",\"volume\":\"11 4\",\"pages\":\"193-9\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2007-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1007/s10006-007-0062-8\",\"citationCount\":\"5\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Mund-, Kiefer- und Gesichtschirurgie : MKG\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1007/s10006-007-0062-8\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Mund-, Kiefer- und Gesichtschirurgie : MKG","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1007/s10006-007-0062-8","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5
摘要
背景:美国田纳西大学口腔颌面外科和内固定研究协会(AO/ASIF)合作,基于自己的回顾性研究,开发了一种髁突头附加系统,用于接受消融手术需要移除下颌髁的患者的即时临时重建。目的:介绍并讨论了新型髁突头附加系统的设计及其在人体解剖研究中的应用。设计和首次体验:髁突替代物由商业纯钛制成,被认为是一个附加系统。它包括一个重建板(2.4 uni - lock系统)和一个可适应的髁头,可以安装在任何一侧。髁突头在内侧方向的偏移使得植入物在解剖学上正确定位。倾斜的椭圆形头在保持下颌关节功能的同时提供较大的接触面积。带有四个不同固定板的髁突头附加件的高度可调节定位有助于术中髁突头的垂直矫正,而无需弯曲新的重建板。在两侧使用的髁头附加件,并与经常使用的2.4 uni - lock钢板相结合,减少了储存,从经济的角度来看是有利的。视角:2006年9月,一项国际前瞻性多中心研究开始评估新髁头附加系统在术后头两年的术中适用性及其功能和美学效果。
[New condylar head system for temporary condylar reconstruction in ablative tumour surgery].
Background: Based on own retrospective studies a condylar head add-on system for immediate, temporary reconstruction in patients undergoing ablative surgery requiring the removal of the manibular condyle has been developed in cooperation with the Department of Oral and Maxillofacial Surgery of the University of Tennessee, USA, and the Association for the Study of Internal Fixation (AO/ASIF).
Purpose: The design of the new condylar head add-on system and its use in an anatomical dissection study on a human cadaver are introduced and discussed. DESIGN AND FIRST EXPERIENCES: The condylar replacement is made of commercial pure titanium and is conceived as an add-on system. It consists of a reconstruction plate (2.4 Uni-LOCK-System) und an adaptable condylar head that can be fitted on either side. The offset of the condylar head in a medial direction allows anatomically correct positioning of the implant. The slanted oval head shall provide a large contact area while maintaining function of the mandibular joint. The height-adjustable positioning of the condylar head add-on with four different fixations plates facilitates an intraoperative vertical correction of the condylar head without necessary bending of a new reconstruction plate. A condylar head add-on used on both sides and combined with the frequently used 2.4 Uni-LOCK-plate benefits from reduced storekeeping and turns out to be advantageous from an economic point of view.
Perspective: An international, prospective multi-center study evaluating the intraoperative applicability of the new condylar head add-on system and its functional as well as aesthetic results during the first two postoperative years has started in September 2006.