Ondrej Hegedűs , Alžbeta Hegedűsová , Silvia Šimková , Vladimír Pavlík , Klaudia Jomová
{"title":"et -原子吸收光谱法和hg -原子吸收光谱法测定蔬菜中硒的评价","authors":"Ondrej Hegedűs , Alžbeta Hegedűsová , Silvia Šimková , Vladimír Pavlík , Klaudia Jomová","doi":"10.1016/j.jprot.2008.01.002","DOIUrl":null,"url":null,"abstract":"<div><p>ET-AAS and HG-AAS methods of selenium determination were compared and evaluated. The ET-AAS method has been followed with deuterium background correction and Zeeman background correction respectively. The following validation parameters were determined: accuracy (under repeatability conditions), trueness, calibration curve and linearity, limit of detection, limit of determination and combined standard uncertainty of the method. The HG-AAS method and the ET-AAS method with Zeeman correction were more suitable for the determination of low selenium concentrations in vegetables. The results were calculated by the standard addition method because of the strong matrix effect.</p></div>","PeriodicalId":15257,"journal":{"name":"Journal of biochemical and biophysical methods","volume":"70 6","pages":"Pages 1287-1291"},"PeriodicalIF":0.0000,"publicationDate":"2008-04-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/j.jprot.2008.01.002","citationCount":"25","resultStr":"{\"title\":\"Evaluation of the ET-AAS and HG-AAS methods of selenium determination in vegetables\",\"authors\":\"Ondrej Hegedűs , Alžbeta Hegedűsová , Silvia Šimková , Vladimír Pavlík , Klaudia Jomová\",\"doi\":\"10.1016/j.jprot.2008.01.002\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>ET-AAS and HG-AAS methods of selenium determination were compared and evaluated. The ET-AAS method has been followed with deuterium background correction and Zeeman background correction respectively. The following validation parameters were determined: accuracy (under repeatability conditions), trueness, calibration curve and linearity, limit of detection, limit of determination and combined standard uncertainty of the method. The HG-AAS method and the ET-AAS method with Zeeman correction were more suitable for the determination of low selenium concentrations in vegetables. The results were calculated by the standard addition method because of the strong matrix effect.</p></div>\",\"PeriodicalId\":15257,\"journal\":{\"name\":\"Journal of biochemical and biophysical methods\",\"volume\":\"70 6\",\"pages\":\"Pages 1287-1291\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2008-04-24\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1016/j.jprot.2008.01.002\",\"citationCount\":\"25\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of biochemical and biophysical methods\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S0165022X0700200X\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of biochemical and biophysical methods","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0165022X0700200X","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Evaluation of the ET-AAS and HG-AAS methods of selenium determination in vegetables
ET-AAS and HG-AAS methods of selenium determination were compared and evaluated. The ET-AAS method has been followed with deuterium background correction and Zeeman background correction respectively. The following validation parameters were determined: accuracy (under repeatability conditions), trueness, calibration curve and linearity, limit of detection, limit of determination and combined standard uncertainty of the method. The HG-AAS method and the ET-AAS method with Zeeman correction were more suitable for the determination of low selenium concentrations in vegetables. The results were calculated by the standard addition method because of the strong matrix effect.