{"title":"连接电流尖峰的电生理学。","authors":"Raymond M Fish, Leslie A Geddes","doi":"10.1007/s10558-008-9059-7","DOIUrl":null,"url":null,"abstract":"<p><p>Connection to a 60-Hz or other voltage source can result in cardiac dysrhythmias, a startle reaction, muscle contractions, and a variety of other physiological responses. Such responses can lead to injury, especially if significant ventricular cardiac dysrhythmias occur, or if a person is working at some height above ground and falls as a result of a musculoskeletal response. Physiological reactions are known to relate to intensity and duration of current exposure. The connection current that flows is a function of the applied voltage at the instant of connection, and the electrical impedance encountered by the voltage source in contact with the skin or other body tissues. In this article we describe a rarely investigated phenomenon, namely a contact, or connection, current spike that is many times higher than the steady-state current. This current spike occurs when an electrical connection is made at a non-zero voltage time in a sine wave or other waveform. Such current spikes may occur when electronic or manual switching or connecting of conductors occurs in electronic instrumentation connected to a patient. These findings are relevant to medical devices and instrumentation and to electrical safety in general.</p>","PeriodicalId":55275,"journal":{"name":"Cardiovascular Engineering (dordrecht, Netherlands)","volume":"8 4","pages":"219-24"},"PeriodicalIF":0.0000,"publicationDate":"2008-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1007/s10558-008-9059-7","citationCount":"7","resultStr":"{\"title\":\"Electrophysiology of connection current spikes.\",\"authors\":\"Raymond M Fish, Leslie A Geddes\",\"doi\":\"10.1007/s10558-008-9059-7\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Connection to a 60-Hz or other voltage source can result in cardiac dysrhythmias, a startle reaction, muscle contractions, and a variety of other physiological responses. Such responses can lead to injury, especially if significant ventricular cardiac dysrhythmias occur, or if a person is working at some height above ground and falls as a result of a musculoskeletal response. Physiological reactions are known to relate to intensity and duration of current exposure. The connection current that flows is a function of the applied voltage at the instant of connection, and the electrical impedance encountered by the voltage source in contact with the skin or other body tissues. In this article we describe a rarely investigated phenomenon, namely a contact, or connection, current spike that is many times higher than the steady-state current. This current spike occurs when an electrical connection is made at a non-zero voltage time in a sine wave or other waveform. Such current spikes may occur when electronic or manual switching or connecting of conductors occurs in electronic instrumentation connected to a patient. These findings are relevant to medical devices and instrumentation and to electrical safety in general.</p>\",\"PeriodicalId\":55275,\"journal\":{\"name\":\"Cardiovascular Engineering (dordrecht, Netherlands)\",\"volume\":\"8 4\",\"pages\":\"219-24\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2008-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1007/s10558-008-9059-7\",\"citationCount\":\"7\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Cardiovascular Engineering (dordrecht, Netherlands)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1007/s10558-008-9059-7\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Cardiovascular Engineering (dordrecht, Netherlands)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1007/s10558-008-9059-7","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Connection to a 60-Hz or other voltage source can result in cardiac dysrhythmias, a startle reaction, muscle contractions, and a variety of other physiological responses. Such responses can lead to injury, especially if significant ventricular cardiac dysrhythmias occur, or if a person is working at some height above ground and falls as a result of a musculoskeletal response. Physiological reactions are known to relate to intensity and duration of current exposure. The connection current that flows is a function of the applied voltage at the instant of connection, and the electrical impedance encountered by the voltage source in contact with the skin or other body tissues. In this article we describe a rarely investigated phenomenon, namely a contact, or connection, current spike that is many times higher than the steady-state current. This current spike occurs when an electrical connection is made at a non-zero voltage time in a sine wave or other waveform. Such current spikes may occur when electronic or manual switching or connecting of conductors occurs in electronic instrumentation connected to a patient. These findings are relevant to medical devices and instrumentation and to electrical safety in general.