用于多片-多视图图像的多类模型观测器。

H C Gifford, A Lehovich, M A King
{"title":"用于多片-多视图图像的多类模型观测器。","authors":"H C Gifford,&nbsp;A Lehovich,&nbsp;M A King","doi":"10.1109/NSSMIC.2006.354223","DOIUrl":null,"url":null,"abstract":"<p><p>A human-model observer for tumor detection-localization studies featuring multislice-multiview (or volumetric) image displays has been introduced. This volumetric observer, an extension of multiclass linear observers previously tested with single-slice and multislice displays, produces rating and localization data by integrating perception measurements from the different image views. A channelized NPW (CNPW) version of the observer was evaluated against humans for a background-known-exactly (BKE) detection task involving localization of Tc-99m Neotect lesions in simulated SPECT lung images. An LROC study evaluated two RBI reconstruction strategies that used different combinations of corrections for attenuation, scatter, and distance-dependent system resolution, and coronal, sagittal, and transverse slices were presented to the observers. Model-observer ranking of these strategies did not match that of the humans. Follow-up studies exploring several possible remedies for the model observer, including strategy-specific search regions and an internal-noise mechanism, showed little change. Future work will examine variations from the BKE assumption as a means of reconciling the rankings.</p>","PeriodicalId":73298,"journal":{"name":"IEEE Nuclear Science Symposium conference record. Nuclear Science Symposium","volume":"3 ","pages":"1687-1691"},"PeriodicalIF":0.0000,"publicationDate":"2006-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1109/NSSMIC.2006.354223","citationCount":"6","resultStr":"{\"title\":\"A Multiclass Model Observer for Multislice-Multiview Images.\",\"authors\":\"H C Gifford,&nbsp;A Lehovich,&nbsp;M A King\",\"doi\":\"10.1109/NSSMIC.2006.354223\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>A human-model observer for tumor detection-localization studies featuring multislice-multiview (or volumetric) image displays has been introduced. This volumetric observer, an extension of multiclass linear observers previously tested with single-slice and multislice displays, produces rating and localization data by integrating perception measurements from the different image views. A channelized NPW (CNPW) version of the observer was evaluated against humans for a background-known-exactly (BKE) detection task involving localization of Tc-99m Neotect lesions in simulated SPECT lung images. An LROC study evaluated two RBI reconstruction strategies that used different combinations of corrections for attenuation, scatter, and distance-dependent system resolution, and coronal, sagittal, and transverse slices were presented to the observers. Model-observer ranking of these strategies did not match that of the humans. Follow-up studies exploring several possible remedies for the model observer, including strategy-specific search regions and an internal-noise mechanism, showed little change. Future work will examine variations from the BKE assumption as a means of reconciling the rankings.</p>\",\"PeriodicalId\":73298,\"journal\":{\"name\":\"IEEE Nuclear Science Symposium conference record. Nuclear Science Symposium\",\"volume\":\"3 \",\"pages\":\"1687-1691\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2006-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1109/NSSMIC.2006.354223\",\"citationCount\":\"6\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"IEEE Nuclear Science Symposium conference record. Nuclear Science Symposium\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/NSSMIC.2006.354223\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Nuclear Science Symposium conference record. Nuclear Science Symposium","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NSSMIC.2006.354223","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 6

摘要

介绍了一种用于肿瘤检测-定位研究的人体模型观察者,该观察者具有多片-多视图(或体积)图像显示功能。这种体积观测器是对先前使用单片和多片显示器进行测试的多类线性观测器的扩展,通过整合来自不同图像视图的感知测量来产生评级和定位数据。对观察者的通道化NPW (CNPW)版本进行了针对人类的背景已知(BKE)检测任务的评估,该任务涉及模拟SPECT肺图像中Tc-99m Neotect病变的定位。一项LROC研究评估了两种RBI重建策略,这些策略使用了衰减、散射和距离相关系统分辨率的不同校正组合,并向观察者展示了冠状、矢状和横向切片。这些策略的模型观察者排名与人类的排名不匹配。后续研究为模型观察者探索了几种可能的补救措施,包括特定策略搜索区域和内部噪声机制,结果显示变化不大。未来的工作将研究BKE假设的变化,作为协调排名的一种手段。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
A Multiclass Model Observer for Multislice-Multiview Images.

A human-model observer for tumor detection-localization studies featuring multislice-multiview (or volumetric) image displays has been introduced. This volumetric observer, an extension of multiclass linear observers previously tested with single-slice and multislice displays, produces rating and localization data by integrating perception measurements from the different image views. A channelized NPW (CNPW) version of the observer was evaluated against humans for a background-known-exactly (BKE) detection task involving localization of Tc-99m Neotect lesions in simulated SPECT lung images. An LROC study evaluated two RBI reconstruction strategies that used different combinations of corrections for attenuation, scatter, and distance-dependent system resolution, and coronal, sagittal, and transverse slices were presented to the observers. Model-observer ranking of these strategies did not match that of the humans. Follow-up studies exploring several possible remedies for the model observer, including strategy-specific search regions and an internal-noise mechanism, showed little change. Future work will examine variations from the BKE assumption as a means of reconciling the rankings.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Ablation Study of Diffusion Model with Transformer Backbone for Low-count PET Denoising. Point-supervised Brain Tumor Segmentation with Box-prompted Medical Segment Anything Model. Subject-aware PET Denoising with Contrastive Adversarial Domain Generalization. Calibration Methodology of an Edgeless PET System Prototype. Tensor Tomography of Dark Field Scatter using X-ray Interferometry with Bi-prisms.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1