{"title":"一种新的无创中心射血dP/dt测量装置。心脏舒张动脉模型dP/dt测量的数学基础。","authors":"Miguel Gorenberg,&nbsp;Hector Rotztein,&nbsp;Alon Marmor","doi":"10.1007/s10558-009-9064-5","DOIUrl":null,"url":null,"abstract":"<p><p>We have developed a novel non-invasive device for the measurement of one of the most sensitive indices of myocardial contractility as represented by the rate of increase of intraventricular pressure (left ventricular dP/dt and arterial dP/dt performance index (dP/dt(ejc)). Up till now, these parameters could be obtained only by invasive catheterization methods. The new technique is based on the concept of applying multiple successive occlusive pressures on the brachial artery from peak systole to diastole using a inflatable cuff and plotting the values against time intervals that leads to the reconstruction of the central aortic pressure noninvasively. The following describes the computer simulator developed for providing a mathematical foundation of the new sensor. At the core of the simulator lies a hemodynamic model of the blood flow on an artery under externally applied pressure. The purpose of the model is to reproduce the experimental results obtained in studies on patients (Gorenberg et al. in Cardiovasc Eng: 305-311, 2004; Gorenberg et al. in Emerg med J 22 (7): 486-489, 2005) and a animal model where ischemia resulted from balloon inflation during coronary catheterization (Gorenberg and Marmor in J Med Eng Technol, 2006) and to describe correlations between the dP/dt(ejc) and other hemodynamic variables. The model has successfully reproduced the trends observed experimentally, providing a solid in-depth understanding of the hemodynamics involved in the new measurement. A high correlation between the dP/dt(ejc) and the rate of pressure rise in the aorta during the ejection phase was observed. dP/dt(ejc) dependence on other hemodynamic parameters was also investigated.</p>","PeriodicalId":55275,"journal":{"name":"Cardiovascular Engineering (dordrecht, Netherlands)","volume":"9 1","pages":"27-31"},"PeriodicalIF":0.0000,"publicationDate":"2009-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1007/s10558-009-9064-5","citationCount":"2","resultStr":"{\"title\":\"A new noninvasive device for measuring central ejection dP/dt mathematical foundation of cardiac dP/dt measurement using a model for a collapsible artery.\",\"authors\":\"Miguel Gorenberg,&nbsp;Hector Rotztein,&nbsp;Alon Marmor\",\"doi\":\"10.1007/s10558-009-9064-5\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>We have developed a novel non-invasive device for the measurement of one of the most sensitive indices of myocardial contractility as represented by the rate of increase of intraventricular pressure (left ventricular dP/dt and arterial dP/dt performance index (dP/dt(ejc)). Up till now, these parameters could be obtained only by invasive catheterization methods. The new technique is based on the concept of applying multiple successive occlusive pressures on the brachial artery from peak systole to diastole using a inflatable cuff and plotting the values against time intervals that leads to the reconstruction of the central aortic pressure noninvasively. The following describes the computer simulator developed for providing a mathematical foundation of the new sensor. At the core of the simulator lies a hemodynamic model of the blood flow on an artery under externally applied pressure. The purpose of the model is to reproduce the experimental results obtained in studies on patients (Gorenberg et al. in Cardiovasc Eng: 305-311, 2004; Gorenberg et al. in Emerg med J 22 (7): 486-489, 2005) and a animal model where ischemia resulted from balloon inflation during coronary catheterization (Gorenberg and Marmor in J Med Eng Technol, 2006) and to describe correlations between the dP/dt(ejc) and other hemodynamic variables. The model has successfully reproduced the trends observed experimentally, providing a solid in-depth understanding of the hemodynamics involved in the new measurement. A high correlation between the dP/dt(ejc) and the rate of pressure rise in the aorta during the ejection phase was observed. dP/dt(ejc) dependence on other hemodynamic parameters was also investigated.</p>\",\"PeriodicalId\":55275,\"journal\":{\"name\":\"Cardiovascular Engineering (dordrecht, Netherlands)\",\"volume\":\"9 1\",\"pages\":\"27-31\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2009-03-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1007/s10558-009-9064-5\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Cardiovascular Engineering (dordrecht, Netherlands)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1007/s10558-009-9064-5\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Cardiovascular Engineering (dordrecht, Netherlands)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1007/s10558-009-9064-5","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

我们开发了一种新型的无创设备,用于测量心室内压力(左心室dP/dt和动脉dP/dt表现指数(dP/dt(ejc))的增加率,这是心肌收缩性最敏感的指标之一。到目前为止,这些参数只能通过有创置管方法获得。这项新技术是基于使用充气袖带对肱动脉从收缩期到舒张期连续施加多个闭塞压力的概念,并根据时间间隔绘制值,从而无创性地重建中央主动脉压力。下面介绍了为提供新传感器的数学基础而开发的计算机模拟器。模拟器的核心是在外部施加压力下动脉血流的血流动力学模型。该模型的目的是再现在患者研究中获得的实验结果(Gorenberg et al. in cardiovascular Eng: 305-311, 2004;Gorenberg等人发表在《新兴医学杂志》22(7):486-489,2005)和冠状动脉导管置入期间球囊膨胀导致缺血的动物模型(Gorenberg和Marmor发表在《医学工程技术杂志》,2006),并描述了dP/dt(ejc)与其他血流动力学变量之间的相关性。该模型成功地再现了实验中观察到的趋势,为新测量中涉及的血流动力学提供了坚实的深入理解。在射血期,dP/dt(ejc)与主动脉压力升高率之间存在高度相关性。dP/dt(ejc)对其他血流动力学参数的依赖性也进行了研究。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
A new noninvasive device for measuring central ejection dP/dt mathematical foundation of cardiac dP/dt measurement using a model for a collapsible artery.

We have developed a novel non-invasive device for the measurement of one of the most sensitive indices of myocardial contractility as represented by the rate of increase of intraventricular pressure (left ventricular dP/dt and arterial dP/dt performance index (dP/dt(ejc)). Up till now, these parameters could be obtained only by invasive catheterization methods. The new technique is based on the concept of applying multiple successive occlusive pressures on the brachial artery from peak systole to diastole using a inflatable cuff and plotting the values against time intervals that leads to the reconstruction of the central aortic pressure noninvasively. The following describes the computer simulator developed for providing a mathematical foundation of the new sensor. At the core of the simulator lies a hemodynamic model of the blood flow on an artery under externally applied pressure. The purpose of the model is to reproduce the experimental results obtained in studies on patients (Gorenberg et al. in Cardiovasc Eng: 305-311, 2004; Gorenberg et al. in Emerg med J 22 (7): 486-489, 2005) and a animal model where ischemia resulted from balloon inflation during coronary catheterization (Gorenberg and Marmor in J Med Eng Technol, 2006) and to describe correlations between the dP/dt(ejc) and other hemodynamic variables. The model has successfully reproduced the trends observed experimentally, providing a solid in-depth understanding of the hemodynamics involved in the new measurement. A high correlation between the dP/dt(ejc) and the rate of pressure rise in the aorta during the ejection phase was observed. dP/dt(ejc) dependence on other hemodynamic parameters was also investigated.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
3D Bioprinting of a Tissue Engineered Human Heart Tissue-Mimicking Materials for Cardiac Imaging Phantom—Section 2: From Fabrication to Optimization Square Root Design for Natural Frequency Module of Dynamic ECG Features—a Preliminary Study Tissue-Mimicking Materials for Cardiac Imaging Phantom—Section 1: From Conception to Materials Selection Biopolymers as Potential Carrier for Effervescent Reaction Based Drug Delivery System in Gastrointestinal Condition
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1