{"title":"运动轴突兴奋性的改变改变了统计MUNE结果。","authors":"Lora A Major,&nbsp;K Ming Chan,&nbsp;Hugh Bostock,&nbsp;Kelvin E Jones","doi":"10.1016/s1567-424x(08)00002-0","DOIUrl":null,"url":null,"abstract":"<p><p>Motor unit number estimation (MUNE) techniques--whether they reflect a true motor unit count or some related index--should not be confounded by changes in the neuromuscular system other than a decline in the number of functional motor units. In neurodegenerative conditions such as amyotrophic lateral sclerosis (ALS), there is evidence of changes in the excitability of motor axons. If changes in axon excitability confound a particular MUNE technique, this would influence the use of that technique in ALS patients. We hypothesized on the basis of computational models that changes in axon membrane excitability would change the outcome of a statistical MUNE test, even though the true number of motor units remained unchanged. To test the validity of the model predictions we induced changes in axon excitability of healthy control subjects by applying a polarizing current while simultaneously carrying out a statistical MUNE test. In a group of 7 subjects we found a significant difference in MUNE as a result of the change in axon excitability produced by the polarizing current (paired t-test, P < 0.05). We conclude that the statistical MUNE method is confounded by changes in axon excitability. Since increasing evidence shows that axon excitability is altered as part of the pathophysiological process underlying ALS, clinical researchers should be cautious when using statistical MUNE with this patient population.</p>","PeriodicalId":85606,"journal":{"name":"Supplements to Clinical neurophysiology","volume":"60 ","pages":"27-37"},"PeriodicalIF":0.0000,"publicationDate":"2009-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/s1567-424x(08)00002-0","citationCount":"2","resultStr":"{\"title\":\"Change in excitability of motor axons modifies statistical MUNE results.\",\"authors\":\"Lora A Major,&nbsp;K Ming Chan,&nbsp;Hugh Bostock,&nbsp;Kelvin E Jones\",\"doi\":\"10.1016/s1567-424x(08)00002-0\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Motor unit number estimation (MUNE) techniques--whether they reflect a true motor unit count or some related index--should not be confounded by changes in the neuromuscular system other than a decline in the number of functional motor units. In neurodegenerative conditions such as amyotrophic lateral sclerosis (ALS), there is evidence of changes in the excitability of motor axons. If changes in axon excitability confound a particular MUNE technique, this would influence the use of that technique in ALS patients. We hypothesized on the basis of computational models that changes in axon membrane excitability would change the outcome of a statistical MUNE test, even though the true number of motor units remained unchanged. To test the validity of the model predictions we induced changes in axon excitability of healthy control subjects by applying a polarizing current while simultaneously carrying out a statistical MUNE test. In a group of 7 subjects we found a significant difference in MUNE as a result of the change in axon excitability produced by the polarizing current (paired t-test, P < 0.05). We conclude that the statistical MUNE method is confounded by changes in axon excitability. Since increasing evidence shows that axon excitability is altered as part of the pathophysiological process underlying ALS, clinical researchers should be cautious when using statistical MUNE with this patient population.</p>\",\"PeriodicalId\":85606,\"journal\":{\"name\":\"Supplements to Clinical neurophysiology\",\"volume\":\"60 \",\"pages\":\"27-37\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2009-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1016/s1567-424x(08)00002-0\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Supplements to Clinical neurophysiology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1016/s1567-424x(08)00002-0\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Supplements to Clinical neurophysiology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1016/s1567-424x(08)00002-0","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

运动单元数估计(MUNE)技术——无论它们是否反映了真实的运动单元数或一些相关指标——不应与神经肌肉系统的变化相混淆,而不是功能性运动单元数量的下降。在神经退行性疾病如肌萎缩侧索硬化症(ALS)中,有证据表明运动轴突的兴奋性发生了变化。如果轴突兴奋性的变化混淆了特定的MUNE技术,这将影响该技术在ALS患者中的应用。在计算模型的基础上,我们假设轴突膜兴奋性的变化会改变统计MUNE检验的结果,即使运动单元的真实数量保持不变。为了验证模型预测的有效性,我们在进行统计MUNE检验的同时,通过施加极化电流诱导健康对照者轴突兴奋性的变化。在一组7名受试者中,我们发现极化电流引起的轴突兴奋性变化导致了MUNE的显著差异(配对t检验,P < 0.05)。我们得出结论,统计MUNE方法与轴突兴奋性的变化相混淆。由于越来越多的证据表明轴突兴奋性作为ALS病理生理过程的一部分而改变,临床研究人员在对这类患者群体使用统计MUNE时应谨慎。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Change in excitability of motor axons modifies statistical MUNE results.

Motor unit number estimation (MUNE) techniques--whether they reflect a true motor unit count or some related index--should not be confounded by changes in the neuromuscular system other than a decline in the number of functional motor units. In neurodegenerative conditions such as amyotrophic lateral sclerosis (ALS), there is evidence of changes in the excitability of motor axons. If changes in axon excitability confound a particular MUNE technique, this would influence the use of that technique in ALS patients. We hypothesized on the basis of computational models that changes in axon membrane excitability would change the outcome of a statistical MUNE test, even though the true number of motor units remained unchanged. To test the validity of the model predictions we induced changes in axon excitability of healthy control subjects by applying a polarizing current while simultaneously carrying out a statistical MUNE test. In a group of 7 subjects we found a significant difference in MUNE as a result of the change in axon excitability produced by the polarizing current (paired t-test, P < 0.05). We conclude that the statistical MUNE method is confounded by changes in axon excitability. Since increasing evidence shows that axon excitability is altered as part of the pathophysiological process underlying ALS, clinical researchers should be cautious when using statistical MUNE with this patient population.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
The auditory steady-state response (ASSR): a translational biomarker for schizophrenia. Auditory-evoked alpha oscillations imply reduced anterior and increased posterior amplitudes in schizophrenia. Early auditory gamma band response abnormalities in first hospitalized schizophrenia. Converging evidence for gamma synchrony deficits in schizophrenia. Connectivity and local activity within the fronto-posterior brain network in schizophrenia.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1