Real-Q肠道病毒实时PCR定量试剂盒的性能评价

Dual Song, Shine Young Kim, Son A Jo, Hyung-Il Hahm, Sang-Hyun Hwang, Young Tak Lim, Hyung Hoi Kim, Chulhun L Chang, Eun Yup Lee
{"title":"Real-Q肠道病毒实时PCR定量试剂盒的性能评价","authors":"Dual Song,&nbsp;Shine Young Kim,&nbsp;Son A Jo,&nbsp;Hyung-Il Hahm,&nbsp;Sang-Hyun Hwang,&nbsp;Young Tak Lim,&nbsp;Hyung Hoi Kim,&nbsp;Chulhun L Chang,&nbsp;Eun Yup Lee","doi":"10.3343/kjlm.2010.30.6.624","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Molecular methods have enabled rapid diagnosis of aseptic meningitis and have reduced both unnecessary therapeutic interventions and medical costs. In this study, we evaluated the analytical performance of the recently developed Real-Q Enterovirus Quantification kit (BioSewoom Inc., Korea).</p><p><strong>Methods: </strong>We evaluated the detection limit, precision, linearity, and cross-reactivity of the Real-Q Enterovirus Quantification kit and compared it with the conventional PCR method. From March to September 2009, we tested 91 CSF specimens from patients who visited the pediatrics department of the university hospital with symptoms of aseptic meningitis or infantile sepsis, and we also tested 48 CSF specimens from patients with febrile convulsion for differential diagnosis.</p><p><strong>Results: </strong>The Real-Q Enterovirus Quantification kit showed good linearity (r=0.997) within a range from 3 × 10(2) to 3 × 10(10) copies/mL, and the detection limit of the kit was 83 copies/mL. The within-run, between-run, and between-day CVs were 5.3-7.6%, 9.5-12.3%, and 11.4-13.4%, respectively. There was no cross reactivity between enteroviruses and various microorganisms. Positive results were obtained for 39.1% (25/64) of the patients suspected of aseptic meningitis and 44.4% (12/27) of the patients suspected of infantile sepsis. However, among the 48 children with febrile conversion, only 4 were positive for enterovirus. Further, the concordance with conventional PCR was high (73/74).</p><p><strong>Conclusions: </strong>The Real-Q Enterovirus Quantification kit showed excellent linearity and high reliability with a broad reportable range. It showed good detection rate when used with clinical specimens and also showed a high concordance with the conventional method. Therefore, this assay would be clinically useful not only in diagnosis of aseptic meningitis but also in differential diagnosis of infantile sepsis.</p>","PeriodicalId":17890,"journal":{"name":"Korean Journal of Laboratory Medicine","volume":"30 6","pages":"624-30"},"PeriodicalIF":0.0000,"publicationDate":"2010-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.3343/kjlm.2010.30.6.624","citationCount":"0","resultStr":"{\"title\":\"[Performance evaluation of Real-Q Enterovirus Quantification kit for enterovirus by real-time PCR].\",\"authors\":\"Dual Song,&nbsp;Shine Young Kim,&nbsp;Son A Jo,&nbsp;Hyung-Il Hahm,&nbsp;Sang-Hyun Hwang,&nbsp;Young Tak Lim,&nbsp;Hyung Hoi Kim,&nbsp;Chulhun L Chang,&nbsp;Eun Yup Lee\",\"doi\":\"10.3343/kjlm.2010.30.6.624\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Molecular methods have enabled rapid diagnosis of aseptic meningitis and have reduced both unnecessary therapeutic interventions and medical costs. In this study, we evaluated the analytical performance of the recently developed Real-Q Enterovirus Quantification kit (BioSewoom Inc., Korea).</p><p><strong>Methods: </strong>We evaluated the detection limit, precision, linearity, and cross-reactivity of the Real-Q Enterovirus Quantification kit and compared it with the conventional PCR method. From March to September 2009, we tested 91 CSF specimens from patients who visited the pediatrics department of the university hospital with symptoms of aseptic meningitis or infantile sepsis, and we also tested 48 CSF specimens from patients with febrile convulsion for differential diagnosis.</p><p><strong>Results: </strong>The Real-Q Enterovirus Quantification kit showed good linearity (r=0.997) within a range from 3 × 10(2) to 3 × 10(10) copies/mL, and the detection limit of the kit was 83 copies/mL. The within-run, between-run, and between-day CVs were 5.3-7.6%, 9.5-12.3%, and 11.4-13.4%, respectively. There was no cross reactivity between enteroviruses and various microorganisms. Positive results were obtained for 39.1% (25/64) of the patients suspected of aseptic meningitis and 44.4% (12/27) of the patients suspected of infantile sepsis. However, among the 48 children with febrile conversion, only 4 were positive for enterovirus. Further, the concordance with conventional PCR was high (73/74).</p><p><strong>Conclusions: </strong>The Real-Q Enterovirus Quantification kit showed excellent linearity and high reliability with a broad reportable range. It showed good detection rate when used with clinical specimens and also showed a high concordance with the conventional method. Therefore, this assay would be clinically useful not only in diagnosis of aseptic meningitis but also in differential diagnosis of infantile sepsis.</p>\",\"PeriodicalId\":17890,\"journal\":{\"name\":\"Korean Journal of Laboratory Medicine\",\"volume\":\"30 6\",\"pages\":\"624-30\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2010-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.3343/kjlm.2010.30.6.624\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Korean Journal of Laboratory Medicine\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.3343/kjlm.2010.30.6.624\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Korean Journal of Laboratory Medicine","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3343/kjlm.2010.30.6.624","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

背景:分子方法使无菌性脑膜炎的快速诊断成为可能,并减少了不必要的治疗干预和医疗费用。在这项研究中,我们评估了最近开发的Real-Q肠道病毒定量试剂盒(BioSewoom Inc.,韩国)的分析性能。方法:对Real-Q肠道病毒定量试剂盒的检出限、精密度、线性度和交叉反应性进行评价,并与传统PCR方法进行比较。2009年3月至9月,我们检测了91例到大学医院儿科就诊的无菌性脑膜炎或婴儿败血症患者的脑脊液标本,并对48例发热惊厥患者的脑脊液标本进行了鉴别诊断。结果:Real-Q肠道病毒定量试剂盒在3 × 10(2) ~ 3 × 10(10) copies/mL范围内线性良好(r=0.997),试剂盒的检出限为83 copies/mL。组内、组间和日间的CVs分别为5.3-7.6%、9.5-12.3%和11.4-13.4%。肠道病毒与多种微生物之间无交叉反应性。39.1%(25/64)怀疑为无菌性脑膜炎,44.4%(12/27)怀疑为婴儿败血症。在48例发热转化患儿中,仅有4例肠道病毒阳性。与传统PCR的一致性较高(73/74)。结论:Real-Q肠道病毒定量试剂盒线性好,可靠性高,报告范围广。该方法在临床标本中具有良好的检出率,与常规方法具有较高的一致性。因此,该方法不仅可用于诊断无菌性脑膜炎,而且可用于婴儿败血症的鉴别诊断。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
[Performance evaluation of Real-Q Enterovirus Quantification kit for enterovirus by real-time PCR].

Background: Molecular methods have enabled rapid diagnosis of aseptic meningitis and have reduced both unnecessary therapeutic interventions and medical costs. In this study, we evaluated the analytical performance of the recently developed Real-Q Enterovirus Quantification kit (BioSewoom Inc., Korea).

Methods: We evaluated the detection limit, precision, linearity, and cross-reactivity of the Real-Q Enterovirus Quantification kit and compared it with the conventional PCR method. From March to September 2009, we tested 91 CSF specimens from patients who visited the pediatrics department of the university hospital with symptoms of aseptic meningitis or infantile sepsis, and we also tested 48 CSF specimens from patients with febrile convulsion for differential diagnosis.

Results: The Real-Q Enterovirus Quantification kit showed good linearity (r=0.997) within a range from 3 × 10(2) to 3 × 10(10) copies/mL, and the detection limit of the kit was 83 copies/mL. The within-run, between-run, and between-day CVs were 5.3-7.6%, 9.5-12.3%, and 11.4-13.4%, respectively. There was no cross reactivity between enteroviruses and various microorganisms. Positive results were obtained for 39.1% (25/64) of the patients suspected of aseptic meningitis and 44.4% (12/27) of the patients suspected of infantile sepsis. However, among the 48 children with febrile conversion, only 4 were positive for enterovirus. Further, the concordance with conventional PCR was high (73/74).

Conclusions: The Real-Q Enterovirus Quantification kit showed excellent linearity and high reliability with a broad reportable range. It showed good detection rate when used with clinical specimens and also showed a high concordance with the conventional method. Therefore, this assay would be clinically useful not only in diagnosis of aseptic meningitis but also in differential diagnosis of infantile sepsis.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Korean Journal of Laboratory Medicine
Korean Journal of Laboratory Medicine 医学-医学实验技术
自引率
0.00%
发文量
1
审稿时长
>12 weeks
期刊最新文献
Green urine – understanding its importance Use of tandem mass spectrometry for newborn screening of 6 lysosomal storage disorders in a Korean population. Prevalence of plasmid-mediated quinolone resistance and its association with extended-spectrum beta-lactamase and AmpC beta-lactamase in Enterobacteriaceae. Antimicrobial resistance determinants in imipenem-nonsusceptible Acinetobacter calcoaceticus-baumannii complex isolated in Daejeon, Korea. Serial interferon-gamma release assays for the diagnosis of latent tuberculosis infection in patients treated with immunosuppressive agents.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1