用于检测β-溶血性链球菌和翠绿菌群链球菌的MicroScan MICroSTREP加抗菌面板的评价。

Korean Journal of Laboratory Medicine Pub Date : 2011-07-01 Epub Date: 2011-06-28 DOI:10.3343/kjlm.2011.31.3.185
Sung Ju Kim, Young Uh, In Ho Jang, Kwan Soo Lee, Soon Deok Park, Kap Jun Yoon
{"title":"用于检测β-溶血性链球菌和翠绿菌群链球菌的MicroScan MICroSTREP加抗菌面板的评价。","authors":"Sung Ju Kim,&nbsp;Young Uh,&nbsp;In Ho Jang,&nbsp;Kwan Soo Lee,&nbsp;Soon Deok Park,&nbsp;Kap Jun Yoon","doi":"10.3343/kjlm.2011.31.3.185","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>In order to determine the clinical usefulness of the MicroScan (Siemens Healthcare Diagnostics, USA) MICroSTREP plus antimicrobial panel (MICroSTREP) for testing antimicrobial susceptibility of β-hemolytic streptococci (BHS) and viridans group streptococci (VGS), we compared the accuracy of MICroSTREP with that of the CLSI reference method.</p><p><strong>Methods: </strong>Seventy-five BHS and 59 VGS isolates were tested for antimicrobial susceptibility to ampicillin, penicillin, cefotaxime, meropenem, erythromycin, clindamycin, levofloxacin, and vancomycin by using MICroSTREP and the CLSI agar dilution method.</p><p><strong>Results: </strong>The overall essential agreement with regard to minimum inhibitory concentrations (MICs) (within ±1 double dilution) between MICroSTREP and the CLSI reference method was 98.2%, and categorical agreement (CA) was 96.9%. For the BHS isolates, the CA for erythromycin was 96.0%, whereas that for cefotaxime, meropenem, levofloxacin, and vancomycin (for ampicillin, penicillin, and clindamycin; 98.7%) was 100%. For the VGS isolates, the CA for penicillin was 84.7% and that for erythromycin, clindamycin, and vancomycin (for meropenem, 86.5%; for ampicillin, 88.1%; and for cefotaxime and levofloxacin, 96.6%) was 100%. All categorical errors of penicillin and ampicillin in the VGS isolates were minor.</p><p><strong>Conclusions: </strong>The accuracy of MICroSTREP is comparable to that of the CLSI reference method, suggesting that this panel can be effective for testing antimicrobial susceptibility of BHS and VGS.</p>","PeriodicalId":17890,"journal":{"name":"Korean Journal of Laboratory Medicine","volume":"31 3","pages":"185-90"},"PeriodicalIF":0.0000,"publicationDate":"2011-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.3343/kjlm.2011.31.3.185","citationCount":"4","resultStr":"{\"title\":\"Evaluation of the MicroScan MICroSTREP plus antimicrobial panel for testing β-hemolytic streptococci and viridans group streptococci.\",\"authors\":\"Sung Ju Kim,&nbsp;Young Uh,&nbsp;In Ho Jang,&nbsp;Kwan Soo Lee,&nbsp;Soon Deok Park,&nbsp;Kap Jun Yoon\",\"doi\":\"10.3343/kjlm.2011.31.3.185\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>In order to determine the clinical usefulness of the MicroScan (Siemens Healthcare Diagnostics, USA) MICroSTREP plus antimicrobial panel (MICroSTREP) for testing antimicrobial susceptibility of β-hemolytic streptococci (BHS) and viridans group streptococci (VGS), we compared the accuracy of MICroSTREP with that of the CLSI reference method.</p><p><strong>Methods: </strong>Seventy-five BHS and 59 VGS isolates were tested for antimicrobial susceptibility to ampicillin, penicillin, cefotaxime, meropenem, erythromycin, clindamycin, levofloxacin, and vancomycin by using MICroSTREP and the CLSI agar dilution method.</p><p><strong>Results: </strong>The overall essential agreement with regard to minimum inhibitory concentrations (MICs) (within ±1 double dilution) between MICroSTREP and the CLSI reference method was 98.2%, and categorical agreement (CA) was 96.9%. For the BHS isolates, the CA for erythromycin was 96.0%, whereas that for cefotaxime, meropenem, levofloxacin, and vancomycin (for ampicillin, penicillin, and clindamycin; 98.7%) was 100%. For the VGS isolates, the CA for penicillin was 84.7% and that for erythromycin, clindamycin, and vancomycin (for meropenem, 86.5%; for ampicillin, 88.1%; and for cefotaxime and levofloxacin, 96.6%) was 100%. All categorical errors of penicillin and ampicillin in the VGS isolates were minor.</p><p><strong>Conclusions: </strong>The accuracy of MICroSTREP is comparable to that of the CLSI reference method, suggesting that this panel can be effective for testing antimicrobial susceptibility of BHS and VGS.</p>\",\"PeriodicalId\":17890,\"journal\":{\"name\":\"Korean Journal of Laboratory Medicine\",\"volume\":\"31 3\",\"pages\":\"185-90\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2011-07-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.3343/kjlm.2011.31.3.185\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Korean Journal of Laboratory Medicine\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.3343/kjlm.2011.31.3.185\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2011/6/28 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Korean Journal of Laboratory Medicine","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3343/kjlm.2011.31.3.185","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2011/6/28 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

摘要

背景:为了确定MicroScan (Siemens Healthcare Diagnostics, USA) MICroSTREP加抗菌面板(MICroSTREP)检测β-溶血性链球菌(BHS)和翠绿菌群链球菌(VGS)抗菌敏感性的临床应用价值,我们比较了MICroSTREP与CLSI参考方法的准确性。方法:采用MICroSTREP和CLSI琼脂稀释法检测75株BHS和59株VGS菌株对氨苄西林、青霉素、头孢噻肟、美罗培南、红霉素、克林霉素、左氧氟沙星、万古霉素的敏感性。结果:MICroSTREP与CLSI参比法在±1倍稀释范围内的最低抑菌浓度(mic)基本一致性为98.2%,分类一致性为96.9%。对于BHS分离株,红霉素的CA为96.0%,而头孢噻肟、美罗培南、左氧氟沙星和万古霉素的CA为96.0%(氨苄西林、青霉素和克林霉素;98.7%)为100%。VGS分离株对青霉素的CA为84.7%,对红霉素、克林霉素和万古霉素的CA为86.5%;氨苄西林为88.1%;对头孢噻肟和左氧氟沙星,96.6%)为100%。所有VGS分离株中青霉素和氨苄西林的分类错误均较小。结论:MICroSTREP的准确性与CLSI参考方法相当,提示该面板可用于BHS和VGS的药敏检测。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

摘要图片

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Evaluation of the MicroScan MICroSTREP plus antimicrobial panel for testing β-hemolytic streptococci and viridans group streptococci.

Background: In order to determine the clinical usefulness of the MicroScan (Siemens Healthcare Diagnostics, USA) MICroSTREP plus antimicrobial panel (MICroSTREP) for testing antimicrobial susceptibility of β-hemolytic streptococci (BHS) and viridans group streptococci (VGS), we compared the accuracy of MICroSTREP with that of the CLSI reference method.

Methods: Seventy-five BHS and 59 VGS isolates were tested for antimicrobial susceptibility to ampicillin, penicillin, cefotaxime, meropenem, erythromycin, clindamycin, levofloxacin, and vancomycin by using MICroSTREP and the CLSI agar dilution method.

Results: The overall essential agreement with regard to minimum inhibitory concentrations (MICs) (within ±1 double dilution) between MICroSTREP and the CLSI reference method was 98.2%, and categorical agreement (CA) was 96.9%. For the BHS isolates, the CA for erythromycin was 96.0%, whereas that for cefotaxime, meropenem, levofloxacin, and vancomycin (for ampicillin, penicillin, and clindamycin; 98.7%) was 100%. For the VGS isolates, the CA for penicillin was 84.7% and that for erythromycin, clindamycin, and vancomycin (for meropenem, 86.5%; for ampicillin, 88.1%; and for cefotaxime and levofloxacin, 96.6%) was 100%. All categorical errors of penicillin and ampicillin in the VGS isolates were minor.

Conclusions: The accuracy of MICroSTREP is comparable to that of the CLSI reference method, suggesting that this panel can be effective for testing antimicrobial susceptibility of BHS and VGS.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Korean Journal of Laboratory Medicine
Korean Journal of Laboratory Medicine 医学-医学实验技术
自引率
0.00%
发文量
1
审稿时长
>12 weeks
期刊最新文献
Green urine – understanding its importance Use of tandem mass spectrometry for newborn screening of 6 lysosomal storage disorders in a Korean population. Prevalence of plasmid-mediated quinolone resistance and its association with extended-spectrum beta-lactamase and AmpC beta-lactamase in Enterobacteriaceae. Antimicrobial resistance determinants in imipenem-nonsusceptible Acinetobacter calcoaceticus-baumannii complex isolated in Daejeon, Korea. Serial interferon-gamma release assays for the diagnosis of latent tuberculosis infection in patients treated with immunosuppressive agents.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1