{"title":"液相色谱串联质谱法定量测定人血浆中阿奇霉素的含量:在生物等效性研究中的应用。","authors":"B Jiang, J Chen, Z Ruan, H Lou, L Yu","doi":"10.1055/s-0031-1301343","DOIUrl":null,"url":null,"abstract":"<p><p>A specific, sensitive and rapid liquid chromatography-electrospray ionization-tandem mass spectrometry (LC-ESI-MS/MS) method has been developed and validated for the determination of azithromycin in human plasma. After deproteinizing the plasma sample with methanol, azithromycin and internal standard (IS: roxithromycin) were separated using a mobile phase comprised of acetonitrile : ammonium acetate buffer (50 mM, containing 0.05% acetic acid)=85:15 on a Hypersil GOLD C18 column (50 mm×2.1 mm ID, dp 1.9 μm). Detection was performed with a tandem mass spectrometer by selective reaction monitoring (SRM) through electrospray ionization. Target ions were monitored at [M+H]+ m/z 749.5→591.5 and 837.7→679.5 in positive electrospray ionization (ESI) mode for azithromycin and IS respectively. Linearity was established for the range of concentrations 2-800 ng/mL with a coefficient of correlation (r) of 0.9996. The lower limit of quantification (LLOQ) was identifiable and reproducible at 2.0 ng/mL. Both intra- and inter-batch standard deviations were less than 15%. The validated method was successfully applied to study the comparative bioavailability of azithromycin for suspension in test vs. reference in healthy Chinese volunteers through the statistical comparison of pharmacokinetic parameters obtained with the two formulations.</p>","PeriodicalId":56084,"journal":{"name":"Arzneimittel-Forschung-Drug Research","volume":"62 5","pages":"230-5"},"PeriodicalIF":0.0000,"publicationDate":"2012-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1055/s-0031-1301343","citationCount":"3","resultStr":"{\"title\":\"Quantification of azithromycin in human plasma by liquid chromatography tandem mass spectrometry: application to a bioequivalence study.\",\"authors\":\"B Jiang, J Chen, Z Ruan, H Lou, L Yu\",\"doi\":\"10.1055/s-0031-1301343\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>A specific, sensitive and rapid liquid chromatography-electrospray ionization-tandem mass spectrometry (LC-ESI-MS/MS) method has been developed and validated for the determination of azithromycin in human plasma. After deproteinizing the plasma sample with methanol, azithromycin and internal standard (IS: roxithromycin) were separated using a mobile phase comprised of acetonitrile : ammonium acetate buffer (50 mM, containing 0.05% acetic acid)=85:15 on a Hypersil GOLD C18 column (50 mm×2.1 mm ID, dp 1.9 μm). Detection was performed with a tandem mass spectrometer by selective reaction monitoring (SRM) through electrospray ionization. Target ions were monitored at [M+H]+ m/z 749.5→591.5 and 837.7→679.5 in positive electrospray ionization (ESI) mode for azithromycin and IS respectively. Linearity was established for the range of concentrations 2-800 ng/mL with a coefficient of correlation (r) of 0.9996. The lower limit of quantification (LLOQ) was identifiable and reproducible at 2.0 ng/mL. Both intra- and inter-batch standard deviations were less than 15%. The validated method was successfully applied to study the comparative bioavailability of azithromycin for suspension in test vs. reference in healthy Chinese volunteers through the statistical comparison of pharmacokinetic parameters obtained with the two formulations.</p>\",\"PeriodicalId\":56084,\"journal\":{\"name\":\"Arzneimittel-Forschung-Drug Research\",\"volume\":\"62 5\",\"pages\":\"230-5\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2012-05-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1055/s-0031-1301343\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Arzneimittel-Forschung-Drug Research\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1055/s-0031-1301343\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2012/2/16 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Arzneimittel-Forschung-Drug Research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1055/s-0031-1301343","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2012/2/16 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3
摘要
建立了一种特异、灵敏、快速的液相色谱-电喷雾电离-串联质谱(LC-ESI-MS/MS)测定人血浆中阿奇霉素的方法。血浆样品经甲醇脱蛋白后,在Hypersil GOLD C18色谱柱(50 mm×2.1 mM ID, dp 1.9 μm)上,用乙腈:醋酸铵缓冲液(50 mM,含0.05%乙酸)=85:15的流动相分离阿奇霉素和内标(IS:罗红霉素)。串联质谱通过电喷雾电离选择性反应监测(SRM)进行检测。在[M+H]+ M /z 749.5→591.5和837.7→679.5正电喷雾电离(ESI)模式下,对阿奇霉素和IS的靶离子进行监测。在浓度2 ~ 800 ng/mL范围内呈线性关系,相关系数(r)为0.9996。定量下限为2.0 ng/mL,可识别,重现性好。批内和批间标准差均小于15%。通过对两种制剂的药动学参数进行统计比较,成功地将验证的方法应用于阿奇霉素混悬液在中国健康志愿者体内的比较生物利用度研究。
Quantification of azithromycin in human plasma by liquid chromatography tandem mass spectrometry: application to a bioequivalence study.
A specific, sensitive and rapid liquid chromatography-electrospray ionization-tandem mass spectrometry (LC-ESI-MS/MS) method has been developed and validated for the determination of azithromycin in human plasma. After deproteinizing the plasma sample with methanol, azithromycin and internal standard (IS: roxithromycin) were separated using a mobile phase comprised of acetonitrile : ammonium acetate buffer (50 mM, containing 0.05% acetic acid)=85:15 on a Hypersil GOLD C18 column (50 mm×2.1 mm ID, dp 1.9 μm). Detection was performed with a tandem mass spectrometer by selective reaction monitoring (SRM) through electrospray ionization. Target ions were monitored at [M+H]+ m/z 749.5→591.5 and 837.7→679.5 in positive electrospray ionization (ESI) mode for azithromycin and IS respectively. Linearity was established for the range of concentrations 2-800 ng/mL with a coefficient of correlation (r) of 0.9996. The lower limit of quantification (LLOQ) was identifiable and reproducible at 2.0 ng/mL. Both intra- and inter-batch standard deviations were less than 15%. The validated method was successfully applied to study the comparative bioavailability of azithromycin for suspension in test vs. reference in healthy Chinese volunteers through the statistical comparison of pharmacokinetic parameters obtained with the two formulations.