儿童日托中心空气中真菌和细菌及弱酸次氯水控制微生物的效果。

Journal of Environmental Monitoring Pub Date : 2012-10-26 Epub Date: 2012-08-21 DOI:10.1039/c2em30113j
Nai-Tzu Chen, Yu-Min Su, Nai-Yun Hsu, Pei-Chih Wu, Huey-Jen Su
{"title":"儿童日托中心空气中真菌和细菌及弱酸次氯水控制微生物的效果。","authors":"Nai-Tzu Chen,&nbsp;Yu-Min Su,&nbsp;Nai-Yun Hsu,&nbsp;Pei-Chih Wu,&nbsp;Huey-Jen Su","doi":"10.1039/c2em30113j","DOIUrl":null,"url":null,"abstract":"<p><p>A three-week-long biological sampling scheme was conducted in two child daycare centers (CDCCs) in order to investigate interdiurnal and diurnal variations in indoor airborne microbes as well as the efficiency of weak acid hypochlorous water (WAHW) on disinfecting indoor microbes. During the second week of sampling, WAHW was sprayed using a fogger in the classroom after children had left and before they returned the next morning. An identical cycle of experiments was performed twice in the winter and spring. Without WAHW intervention, the respective mean of the indoor concentrations and I/O ratios were 8732-47581 CFU m(-3) and 0.96-2.53 for fungi, and 6706-28998 CFU m(-3) and 1.10-11.92 for bacteria, showing severe bio-contamination in the CDCCs. Moreover, a relatively high level of bacterial pollution was found at noon, whereas a greater fungal pollution could be detected in the morning and at noon. Among five school days, the fungal and bacterial pollution may be higher on Monday and on Wednesday, Thursday, and Friday, respectively. Furthermore, with WAHW intervention, the indoor microbial concentrations and I/O ratios were decreased significantly. The reduction of I/O ratios caused by WAHW disinfection was accomplished in the morning for bacteria and in the morning, at noon, and in the afternoon for fungi. In conclusion, this study clearly clarified the risky period during which children may be exposed to hazardous environments, and demonstrated the effectiveness of spraying WAHW the night before on decontaminating indoor airborne microbes on the following day, especially in the case of fungi.</p>","PeriodicalId":50202,"journal":{"name":"Journal of Environmental Monitoring","volume":"14 10","pages":"2692-7"},"PeriodicalIF":0.0000,"publicationDate":"2012-10-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1039/c2em30113j","citationCount":"9","resultStr":"{\"title\":\"Airborne fungi and bacteria in child daycare centers and the effectiveness of weak acid hypochlorous water on controlling microbes.\",\"authors\":\"Nai-Tzu Chen,&nbsp;Yu-Min Su,&nbsp;Nai-Yun Hsu,&nbsp;Pei-Chih Wu,&nbsp;Huey-Jen Su\",\"doi\":\"10.1039/c2em30113j\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>A three-week-long biological sampling scheme was conducted in two child daycare centers (CDCCs) in order to investigate interdiurnal and diurnal variations in indoor airborne microbes as well as the efficiency of weak acid hypochlorous water (WAHW) on disinfecting indoor microbes. During the second week of sampling, WAHW was sprayed using a fogger in the classroom after children had left and before they returned the next morning. An identical cycle of experiments was performed twice in the winter and spring. Without WAHW intervention, the respective mean of the indoor concentrations and I/O ratios were 8732-47581 CFU m(-3) and 0.96-2.53 for fungi, and 6706-28998 CFU m(-3) and 1.10-11.92 for bacteria, showing severe bio-contamination in the CDCCs. Moreover, a relatively high level of bacterial pollution was found at noon, whereas a greater fungal pollution could be detected in the morning and at noon. Among five school days, the fungal and bacterial pollution may be higher on Monday and on Wednesday, Thursday, and Friday, respectively. Furthermore, with WAHW intervention, the indoor microbial concentrations and I/O ratios were decreased significantly. The reduction of I/O ratios caused by WAHW disinfection was accomplished in the morning for bacteria and in the morning, at noon, and in the afternoon for fungi. In conclusion, this study clearly clarified the risky period during which children may be exposed to hazardous environments, and demonstrated the effectiveness of spraying WAHW the night before on decontaminating indoor airborne microbes on the following day, especially in the case of fungi.</p>\",\"PeriodicalId\":50202,\"journal\":{\"name\":\"Journal of Environmental Monitoring\",\"volume\":\"14 10\",\"pages\":\"2692-7\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2012-10-26\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1039/c2em30113j\",\"citationCount\":\"9\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Environmental Monitoring\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1039/c2em30113j\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2012/8/21 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Environmental Monitoring","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1039/c2em30113j","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2012/8/21 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 9

摘要

在两所儿童日托中心(CDCCs)进行了为期3周的室内空气微生物的昼夜变化,以及弱酸次氯水(WAHW)对室内微生物的消毒效果。在抽样的第二周,在孩子们离开后和第二天早上回来之前,在教室里用雾化器喷洒WAHW。在冬季和春季进行了两次相同周期的实验。在没有WAHW干预的情况下,真菌的室内浓度平均值为8732 ~ 47581 CFU m(-3), I/O比值为0.96 ~ 2.53,细菌的室内浓度平均值为6706 ~ 28998 CFU m(-3), I/O比值为1.10 ~ 11.92,表明CDCCs存在严重的生物污染。此外,中午时段细菌污染程度较高,而上午和中午时段真菌污染程度较高。在5个上课日中,真菌和细菌污染可能在周一和周三、周四、周五分别较高。此外,WAHW干预显著降低了室内微生物浓度和I/O比。WAHW消毒对细菌的I/O比降低在上午完成,对真菌的I/O比降低在上午、中午和下午完成。综上所述,本研究明确了儿童可能暴露于危险环境的危险期,并证明了前一天晚上喷洒WAHW对第二天室内空气微生物的净化效果,特别是对真菌的效果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Airborne fungi and bacteria in child daycare centers and the effectiveness of weak acid hypochlorous water on controlling microbes.

A three-week-long biological sampling scheme was conducted in two child daycare centers (CDCCs) in order to investigate interdiurnal and diurnal variations in indoor airborne microbes as well as the efficiency of weak acid hypochlorous water (WAHW) on disinfecting indoor microbes. During the second week of sampling, WAHW was sprayed using a fogger in the classroom after children had left and before they returned the next morning. An identical cycle of experiments was performed twice in the winter and spring. Without WAHW intervention, the respective mean of the indoor concentrations and I/O ratios were 8732-47581 CFU m(-3) and 0.96-2.53 for fungi, and 6706-28998 CFU m(-3) and 1.10-11.92 for bacteria, showing severe bio-contamination in the CDCCs. Moreover, a relatively high level of bacterial pollution was found at noon, whereas a greater fungal pollution could be detected in the morning and at noon. Among five school days, the fungal and bacterial pollution may be higher on Monday and on Wednesday, Thursday, and Friday, respectively. Furthermore, with WAHW intervention, the indoor microbial concentrations and I/O ratios were decreased significantly. The reduction of I/O ratios caused by WAHW disinfection was accomplished in the morning for bacteria and in the morning, at noon, and in the afternoon for fungi. In conclusion, this study clearly clarified the risky period during which children may be exposed to hazardous environments, and demonstrated the effectiveness of spraying WAHW the night before on decontaminating indoor airborne microbes on the following day, especially in the case of fungi.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Environmental Monitoring
Journal of Environmental Monitoring 环境科学-分析化学
自引率
0.00%
发文量
0
审稿时长
2.3 months
期刊最新文献
Total Quality Management (Tqm) As a Prerequisite For Improving The Competitiveness In Waste Management And Waste Reprocessing Micro, Small And Medium Enterprises To Achieve Business Excellence Experimental Investigation on the Impact of Sulphate and Chloride on High Volume Fly Ash Concrete Leachate Characteristics and its Treatment Techniques - A Review Emerging Trend in Power Generation and Utilization Mitigations for Sustainability of the Megacities
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1