样品处理和贮存时间对马血浆中总CO2稳定性的影响。

S H Tinkler, L L Couëtil, P D Constable
{"title":"样品处理和贮存时间对马血浆中总CO2稳定性的影响。","authors":"S H Tinkler,&nbsp;L L Couëtil,&nbsp;P D Constable","doi":"10.1111/j.2042-3306.2012.00610.x","DOIUrl":null,"url":null,"abstract":"<p><strong>Reasons for performing study: </strong>The stability of total CO2 concentration (ctCO2) in plasma is influenced by storage temperature and handling during sample processing. Conflicting information exists regarding the stability of ctCO2 in equine plasma over time, and the effect of centrifugation on the measured value for plasma ctCO2 is unclear.</p><p><strong>Objectives: </strong>To determine plasma ctCO2 stability over 5 days when equine blood is collected into Vacutainer tubes, centrifuged within 30 min of collection, and stored at 4 degrees C; and to determine whether a delay in centrifugation increases the rate at which plasma ctCO2 decreases over time.</p><p><strong>Methods: </strong>Blood was collected from 6 adult horses into 3 ml plastic Vacutainer tubes and randomly assigned to be centrifuged immediately, or after, storage. Plasma ctCO2 was measured in triplicate at 0, 24, 48, 72 and 96 h after collection using a NOVA-4 analyser Data were analysed using multivariable linear regression, with P < 0.05 being defined as significant.</p><p><strong>Results: </strong>Plasma ctCO2 decreased linearly over time during storage at 4 degrees C. The measured value for ctCO2 decreased at a faster rate (-0.28 mmol/l/day; P < 0.0001) when centrifugation was delayed, compared with immediate centrifugation (-0.10 mmol/l/day). There was a significant effect of sequence of sample analysis on the ctCO2 value when measured in triplicate: the second and third measurements were 0.31 and 0.41 mmol/l lower than the first measurement, respectively.</p><p><strong>Conclusions: </strong>Blood samples collected from horses into Vacutainer tubes should be centrifuged immediately after collection and analysed as soon as possible to ensure accurate values for plasma ctCO2.</p><p><strong>Potential relevance: </strong>Failure to centrifuge, or excessive delay in measuring ctCO2 after centrifugation, produces values significantly lower than the true value.</p>","PeriodicalId":11801,"journal":{"name":"Equine veterinary journal. Supplement","volume":" 43","pages":"57-61"},"PeriodicalIF":0.0000,"publicationDate":"2012-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1111/j.2042-3306.2012.00610.x","citationCount":"11","resultStr":"{\"title\":\"Effect of sample handling and storage time on the stability of total CO2 in equine plasma.\",\"authors\":\"S H Tinkler,&nbsp;L L Couëtil,&nbsp;P D Constable\",\"doi\":\"10.1111/j.2042-3306.2012.00610.x\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Reasons for performing study: </strong>The stability of total CO2 concentration (ctCO2) in plasma is influenced by storage temperature and handling during sample processing. Conflicting information exists regarding the stability of ctCO2 in equine plasma over time, and the effect of centrifugation on the measured value for plasma ctCO2 is unclear.</p><p><strong>Objectives: </strong>To determine plasma ctCO2 stability over 5 days when equine blood is collected into Vacutainer tubes, centrifuged within 30 min of collection, and stored at 4 degrees C; and to determine whether a delay in centrifugation increases the rate at which plasma ctCO2 decreases over time.</p><p><strong>Methods: </strong>Blood was collected from 6 adult horses into 3 ml plastic Vacutainer tubes and randomly assigned to be centrifuged immediately, or after, storage. Plasma ctCO2 was measured in triplicate at 0, 24, 48, 72 and 96 h after collection using a NOVA-4 analyser Data were analysed using multivariable linear regression, with P < 0.05 being defined as significant.</p><p><strong>Results: </strong>Plasma ctCO2 decreased linearly over time during storage at 4 degrees C. The measured value for ctCO2 decreased at a faster rate (-0.28 mmol/l/day; P < 0.0001) when centrifugation was delayed, compared with immediate centrifugation (-0.10 mmol/l/day). There was a significant effect of sequence of sample analysis on the ctCO2 value when measured in triplicate: the second and third measurements were 0.31 and 0.41 mmol/l lower than the first measurement, respectively.</p><p><strong>Conclusions: </strong>Blood samples collected from horses into Vacutainer tubes should be centrifuged immediately after collection and analysed as soon as possible to ensure accurate values for plasma ctCO2.</p><p><strong>Potential relevance: </strong>Failure to centrifuge, or excessive delay in measuring ctCO2 after centrifugation, produces values significantly lower than the true value.</p>\",\"PeriodicalId\":11801,\"journal\":{\"name\":\"Equine veterinary journal. Supplement\",\"volume\":\" 43\",\"pages\":\"57-61\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2012-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1111/j.2042-3306.2012.00610.x\",\"citationCount\":\"11\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Equine veterinary journal. Supplement\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1111/j.2042-3306.2012.00610.x\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Equine veterinary journal. Supplement","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1111/j.2042-3306.2012.00610.x","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 11

摘要

开展研究的原因:血浆中总CO2浓度(ctCO2)的稳定性受到样品处理过程中储存温度和处理的影响。关于马血浆中ctCO2随时间的稳定性存在矛盾的信息,离心对血浆ctCO2测量值的影响尚不清楚。目的:测定马血采集到真空管中,采集30分钟内离心,4℃保存后5天内血浆ctCO2的稳定性;并确定离心延迟是否会增加血浆ctCO2随时间降低的速率。方法:取6匹成年马的血液,装入3 ml的塑料真空管中,随机选择立即离心或保存后离心。采用NOVA-4分析仪分别于采集后0、24、48、72和96 h测量3个重复的血浆ctCO2。数据采用多变量线性回归分析,以P < 0.05为显著性。结果:血浆ctCO2随时间呈线性下降,ctCO2测量值下降速度更快(-0.28 mmol/l/d;P < 0.0001),与立即离心(-0.10 mmol/l/day)比较。在三次重复测量时,样品分析顺序对ctCO2值有显著影响:第二次和第三次测量分别比第一次测量低0.31和0.41 mmol/l。结论:从马体内采集的血液标本应在采集后立即离心,并尽快进行分析,以确保血浆ctCO2值准确。潜在相关性:离心失败,或在离心后测量ctCO2的时间过长,产生的值明显低于真实值。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Effect of sample handling and storage time on the stability of total CO2 in equine plasma.

Reasons for performing study: The stability of total CO2 concentration (ctCO2) in plasma is influenced by storage temperature and handling during sample processing. Conflicting information exists regarding the stability of ctCO2 in equine plasma over time, and the effect of centrifugation on the measured value for plasma ctCO2 is unclear.

Objectives: To determine plasma ctCO2 stability over 5 days when equine blood is collected into Vacutainer tubes, centrifuged within 30 min of collection, and stored at 4 degrees C; and to determine whether a delay in centrifugation increases the rate at which plasma ctCO2 decreases over time.

Methods: Blood was collected from 6 adult horses into 3 ml plastic Vacutainer tubes and randomly assigned to be centrifuged immediately, or after, storage. Plasma ctCO2 was measured in triplicate at 0, 24, 48, 72 and 96 h after collection using a NOVA-4 analyser Data were analysed using multivariable linear regression, with P < 0.05 being defined as significant.

Results: Plasma ctCO2 decreased linearly over time during storage at 4 degrees C. The measured value for ctCO2 decreased at a faster rate (-0.28 mmol/l/day; P < 0.0001) when centrifugation was delayed, compared with immediate centrifugation (-0.10 mmol/l/day). There was a significant effect of sequence of sample analysis on the ctCO2 value when measured in triplicate: the second and third measurements were 0.31 and 0.41 mmol/l lower than the first measurement, respectively.

Conclusions: Blood samples collected from horses into Vacutainer tubes should be centrifuged immediately after collection and analysed as soon as possible to ensure accurate values for plasma ctCO2.

Potential relevance: Failure to centrifuge, or excessive delay in measuring ctCO2 after centrifugation, produces values significantly lower than the true value.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Dose titration of the clinical efficacy of intravenously administered flunixin meglumine in a reversible model of equine foot lameness. Influence of head and neck position on radiographic measurement of intervertebral distances between thoracic dorsal spinous processes in clinically sound horses. Retrospective study investigating causes of abnormal respiratory noise in horses following prosthetic laryngoplasty. Selenium deficiency associations with gender, breed, serum vitamin E and creatine kinase, clinical signs and diagnoses in horses of different age groups: a retrospective examination 1996-2011. Acquired equine polyneuropathy in Norway and Sweden: a clinical and epidemiological study.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1