[基于LAMP方法开发的Loopamp支原体P检测试剂盒的实用性]。

Chikashi Matsuda, Takeshi Taketani, Sizue Takeuchi, Yuki Taniguchi, Maki Nagira, Hidehiko Moriyama, Hiroshi Shibata, Atsushi Nagai
{"title":"[基于LAMP方法开发的Loopamp支原体P检测试剂盒的实用性]。","authors":"Chikashi Matsuda,&nbsp;Takeshi Taketani,&nbsp;Sizue Takeuchi,&nbsp;Yuki Taniguchi,&nbsp;Maki Nagira,&nbsp;Hidehiko Moriyama,&nbsp;Hiroshi Shibata,&nbsp;Atsushi Nagai","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>Pathogenic bacteria of Mycoplasma pneumonia, Mycoplasma pneumoniae, do not respond to β-lactam antimicrobial agents. Therefore, it is clinically important to promptly identify infection with this type of bacteria. However, conventional examination methods such as culture and antibody tests are not useful for the rapid diagnosis of this bacterial type. In this study, we examined a Loopamp Mycoplasma P-detecting Reagent Kit developed based on the LAMP (Loop-mediated isothermal amplification) method, which may overcome the limitations of the conventional methods. The consistency rate for the conventional polymerase chain reaction (PCR) method was 98.3%. That for a rapid antibody test, immunocard Mycoplasma antibody, was 54.0%, suggesting the limitation of the rapid antibody test. We compared a pretreatment method using a Loopamp PURE DNA Extraction Kit, as a simple DNA extraction method, with that using a QIAamp DNA Mini Kit. The consistency rate was 91.4%, suggesting the usefulness of the simple DNA extraction method. The use of this kit may facilitate a more rapid diagnosis. The Loopamp Mycoplasma P-detecting Reagent Kit is useful for the accurate and rapid diagnosis of Mycoplasma pneumoniae infection.</p>","PeriodicalId":74740,"journal":{"name":"Rinsho Biseibutsu Jinsoku Shindan Kenkyukai shi = JARMAM : Journal of the Association for Rapid Method and Automation in Microbiology","volume":"23 2","pages":"53-9"},"PeriodicalIF":0.0000,"publicationDate":"2013-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"[Usefulness of the Loopamp Mycoplasma P Detecting Reagent Kit developed based on the LAMP method].\",\"authors\":\"Chikashi Matsuda,&nbsp;Takeshi Taketani,&nbsp;Sizue Takeuchi,&nbsp;Yuki Taniguchi,&nbsp;Maki Nagira,&nbsp;Hidehiko Moriyama,&nbsp;Hiroshi Shibata,&nbsp;Atsushi Nagai\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Pathogenic bacteria of Mycoplasma pneumonia, Mycoplasma pneumoniae, do not respond to β-lactam antimicrobial agents. Therefore, it is clinically important to promptly identify infection with this type of bacteria. However, conventional examination methods such as culture and antibody tests are not useful for the rapid diagnosis of this bacterial type. In this study, we examined a Loopamp Mycoplasma P-detecting Reagent Kit developed based on the LAMP (Loop-mediated isothermal amplification) method, which may overcome the limitations of the conventional methods. The consistency rate for the conventional polymerase chain reaction (PCR) method was 98.3%. That for a rapid antibody test, immunocard Mycoplasma antibody, was 54.0%, suggesting the limitation of the rapid antibody test. We compared a pretreatment method using a Loopamp PURE DNA Extraction Kit, as a simple DNA extraction method, with that using a QIAamp DNA Mini Kit. The consistency rate was 91.4%, suggesting the usefulness of the simple DNA extraction method. The use of this kit may facilitate a more rapid diagnosis. The Loopamp Mycoplasma P-detecting Reagent Kit is useful for the accurate and rapid diagnosis of Mycoplasma pneumoniae infection.</p>\",\"PeriodicalId\":74740,\"journal\":{\"name\":\"Rinsho Biseibutsu Jinsoku Shindan Kenkyukai shi = JARMAM : Journal of the Association for Rapid Method and Automation in Microbiology\",\"volume\":\"23 2\",\"pages\":\"53-9\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2013-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Rinsho Biseibutsu Jinsoku Shindan Kenkyukai shi = JARMAM : Journal of the Association for Rapid Method and Automation in Microbiology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Rinsho Biseibutsu Jinsoku Shindan Kenkyukai shi = JARMAM : Journal of the Association for Rapid Method and Automation in Microbiology","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

致病菌肺炎支原体,肺炎支原体,不响应β-内酰胺抗菌剂。因此,及时识别这种细菌的感染在临床上非常重要。然而,传统的检查方法,如培养和抗体试验,对这种细菌类型的快速诊断是无用的。本研究基于LAMP (Loop-mediated isothermal amplification,环介导等温扩增)方法开发的Loopamp支原体p检测试剂盒,克服了传统方法的局限性。传统聚合酶链反应(PCR)方法的符合率为98.3%。快速抗体检测支原体抗体阳性率为54.0%,提示快速抗体检测的局限性。我们比较了使用Loopamp PURE DNA提取试剂盒作为简单DNA提取方法的预处理方法与使用QIAamp DNA Mini Kit的预处理方法。符合率为91.4%,表明简易DNA提取方法的有效性。使用这种试剂盒可以促进更快速的诊断。Loopamp支原体p检测试剂盒可用于肺炎支原体感染的准确、快速诊断。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
[Usefulness of the Loopamp Mycoplasma P Detecting Reagent Kit developed based on the LAMP method].

Pathogenic bacteria of Mycoplasma pneumonia, Mycoplasma pneumoniae, do not respond to β-lactam antimicrobial agents. Therefore, it is clinically important to promptly identify infection with this type of bacteria. However, conventional examination methods such as culture and antibody tests are not useful for the rapid diagnosis of this bacterial type. In this study, we examined a Loopamp Mycoplasma P-detecting Reagent Kit developed based on the LAMP (Loop-mediated isothermal amplification) method, which may overcome the limitations of the conventional methods. The consistency rate for the conventional polymerase chain reaction (PCR) method was 98.3%. That for a rapid antibody test, immunocard Mycoplasma antibody, was 54.0%, suggesting the limitation of the rapid antibody test. We compared a pretreatment method using a Loopamp PURE DNA Extraction Kit, as a simple DNA extraction method, with that using a QIAamp DNA Mini Kit. The consistency rate was 91.4%, suggesting the usefulness of the simple DNA extraction method. The use of this kit may facilitate a more rapid diagnosis. The Loopamp Mycoplasma P-detecting Reagent Kit is useful for the accurate and rapid diagnosis of Mycoplasma pneumoniae infection.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
A Japanese Case of COVID-19 Caused by Omicron Strain with Y453F Substitution. [Evaluation of Methicillin Resistance Determination Time for MRSA Using Fully Automated Rapid Identification Susceptibility testing system RAISAS S4]. [Evaluation of the Clinical Validity of the Clostridioides difficile Nucleic Acid Detection Kit "Smart Gene® CD ToxinB"]. [Relationship between Serotypes and Biotypes of Yersinia enterocolitica and the Names of Identified Bacteria in the Microbial Identification and Susceptibility Testing Devices]. Comparison of Microorganism Detection, Time to Positivity, and Time-Dependent Shift in Viable Bacterial Count from VersaTREK and BacT/ALERT 3D Blood Culture Systems.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1