{"title":"我们是否在误导呼吸间隔器的使用者?","authors":"Mark J Sanders, Ronald Bruin","doi":"10.4104/pcrj.2013.00103","DOIUrl":null,"url":null,"abstract":"VHC whistles would be activated if the patient goes beyond a flow rate of 60 L/min (the top end of the ideal inspiratory flow rate). However, our research with three whistle-containing VHCs suggests that this appears to be an erroneous assumption and, unwittingly, we may be misleading patients and therefore contributing to reduced patient care. We measured the whistle-activation flow rates for three different makes of VHCs: Able Spacer (Clement Clarke), AeroChamber Plus (GSK), and Optichamber Diamond (Philips Respironics). A calibrated waveform generator (Pulmonary Waveform Generator System, MH Custom Design & Mfg L.C., Utah, USA) was used to create a standardised vacuum force similar to a human inhalation. The performance of three samples of each device was assessed when used with a range of popular drug pMDIs (see Table). The vacuum force was repeated at 1 L/min incremental amounts until the VHCwhistle sounded. Two operatives agreed the whistle sounding. Three recordings of each VHC-drug pMDI combination were carried out (n=54 tests) and the flow rates recorded. The data show that there is a wide variation in the performance of a VHC-whistle as a function of the inhaler to which it is attached. In many instances the whistle first activates at a flow rate well beyond what would be considered acceptable in order to promote effective drug deposition. This phenomenon can be explained. When the patient inhales from the VHC, air will be drawn in through a combination of two routes – the whistle, and the channels surrounding the canister of Dear Sirs, The UK Drug Tariff lists a number of spacer and valved holding chamber (VHC) products for use with pressurised metered dose inhalers (pMDIs). These add-on devices have the double objective of improving the delivery of drug, and making the inhalation procedure easier for the patient. VHCs, in particular, help the user by eliminating the requirement that the slow deep inspiration coincides with the actuation of the pMDI – a manoeuvre which can be particularly tricky for children and the elderly, although poor coordination is worryingly common in pMDI users irrespective of age. VHC users should inhale gently, using either tidal breathing or an approximate 30 L/min inspiratory flow, which facilitates lung deposition of the drug particles. Some VHC products include an alert whistle designed to sound “when the patient is breathing in too quickly”, as this type of forceful inspiratory manoeuvre increases the likelihood of oral/pharyngeal drug deposition. It is known that healthcare trainers use the whistle-alert as a tool to titrate the Prim Care Respir J 2013; 22(4): 466-467","PeriodicalId":48998,"journal":{"name":"Primary Care Respiratory Journal","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2013-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.4104/pcrj.2013.00103","citationCount":"3","resultStr":"{\"title\":\"Are we misleading users of respiratory spacer devices?\",\"authors\":\"Mark J Sanders, Ronald Bruin\",\"doi\":\"10.4104/pcrj.2013.00103\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"VHC whistles would be activated if the patient goes beyond a flow rate of 60 L/min (the top end of the ideal inspiratory flow rate). However, our research with three whistle-containing VHCs suggests that this appears to be an erroneous assumption and, unwittingly, we may be misleading patients and therefore contributing to reduced patient care. We measured the whistle-activation flow rates for three different makes of VHCs: Able Spacer (Clement Clarke), AeroChamber Plus (GSK), and Optichamber Diamond (Philips Respironics). A calibrated waveform generator (Pulmonary Waveform Generator System, MH Custom Design & Mfg L.C., Utah, USA) was used to create a standardised vacuum force similar to a human inhalation. The performance of three samples of each device was assessed when used with a range of popular drug pMDIs (see Table). The vacuum force was repeated at 1 L/min incremental amounts until the VHCwhistle sounded. Two operatives agreed the whistle sounding. Three recordings of each VHC-drug pMDI combination were carried out (n=54 tests) and the flow rates recorded. The data show that there is a wide variation in the performance of a VHC-whistle as a function of the inhaler to which it is attached. In many instances the whistle first activates at a flow rate well beyond what would be considered acceptable in order to promote effective drug deposition. This phenomenon can be explained. When the patient inhales from the VHC, air will be drawn in through a combination of two routes – the whistle, and the channels surrounding the canister of Dear Sirs, The UK Drug Tariff lists a number of spacer and valved holding chamber (VHC) products for use with pressurised metered dose inhalers (pMDIs). These add-on devices have the double objective of improving the delivery of drug, and making the inhalation procedure easier for the patient. VHCs, in particular, help the user by eliminating the requirement that the slow deep inspiration coincides with the actuation of the pMDI – a manoeuvre which can be particularly tricky for children and the elderly, although poor coordination is worryingly common in pMDI users irrespective of age. VHC users should inhale gently, using either tidal breathing or an approximate 30 L/min inspiratory flow, which facilitates lung deposition of the drug particles. Some VHC products include an alert whistle designed to sound “when the patient is breathing in too quickly”, as this type of forceful inspiratory manoeuvre increases the likelihood of oral/pharyngeal drug deposition. It is known that healthcare trainers use the whistle-alert as a tool to titrate the Prim Care Respir J 2013; 22(4): 466-467\",\"PeriodicalId\":48998,\"journal\":{\"name\":\"Primary Care Respiratory Journal\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2013-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.4104/pcrj.2013.00103\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Primary Care Respiratory Journal\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.4104/pcrj.2013.00103\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Primary Care Respiratory Journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4104/pcrj.2013.00103","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Are we misleading users of respiratory spacer devices?
VHC whistles would be activated if the patient goes beyond a flow rate of 60 L/min (the top end of the ideal inspiratory flow rate). However, our research with three whistle-containing VHCs suggests that this appears to be an erroneous assumption and, unwittingly, we may be misleading patients and therefore contributing to reduced patient care. We measured the whistle-activation flow rates for three different makes of VHCs: Able Spacer (Clement Clarke), AeroChamber Plus (GSK), and Optichamber Diamond (Philips Respironics). A calibrated waveform generator (Pulmonary Waveform Generator System, MH Custom Design & Mfg L.C., Utah, USA) was used to create a standardised vacuum force similar to a human inhalation. The performance of three samples of each device was assessed when used with a range of popular drug pMDIs (see Table). The vacuum force was repeated at 1 L/min incremental amounts until the VHCwhistle sounded. Two operatives agreed the whistle sounding. Three recordings of each VHC-drug pMDI combination were carried out (n=54 tests) and the flow rates recorded. The data show that there is a wide variation in the performance of a VHC-whistle as a function of the inhaler to which it is attached. In many instances the whistle first activates at a flow rate well beyond what would be considered acceptable in order to promote effective drug deposition. This phenomenon can be explained. When the patient inhales from the VHC, air will be drawn in through a combination of two routes – the whistle, and the channels surrounding the canister of Dear Sirs, The UK Drug Tariff lists a number of spacer and valved holding chamber (VHC) products for use with pressurised metered dose inhalers (pMDIs). These add-on devices have the double objective of improving the delivery of drug, and making the inhalation procedure easier for the patient. VHCs, in particular, help the user by eliminating the requirement that the slow deep inspiration coincides with the actuation of the pMDI – a manoeuvre which can be particularly tricky for children and the elderly, although poor coordination is worryingly common in pMDI users irrespective of age. VHC users should inhale gently, using either tidal breathing or an approximate 30 L/min inspiratory flow, which facilitates lung deposition of the drug particles. Some VHC products include an alert whistle designed to sound “when the patient is breathing in too quickly”, as this type of forceful inspiratory manoeuvre increases the likelihood of oral/pharyngeal drug deposition. It is known that healthcare trainers use the whistle-alert as a tool to titrate the Prim Care Respir J 2013; 22(4): 466-467
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Primary Care Respiratory Journal
Primary Care Respiratory Journal PRIMARY HEALTH CARE-RESPIRATORY SYSTEM
自引率
0.00%
发文量
0
审稿时长
6-12 weeks
期刊最新文献
Management, morbidity and mortality of COPD during an 11-year period: an observational retrospective epidemiological register study in Sweden (PATHOS). Chronic disease co-morbidity of asthma and unscheduled asthma care among adults: results of the national telephone health interview survey German Health Update (GEDA) 2009 and 2010. Transgenerational occurrence of allergic disease and autoimmunity: general practice-based epidemiological research. Are GOLD ABCD groups better associated with health status and costs than GOLD 1234 grades? A cross-sectional study. Indolent pneumonia in a pregnant recent immigrant from Ethiopia: think TB.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1