用两种贴面原理和两种烧成温度与钛结合的瓷。

Q Dentistry Swedish dental journal Pub Date : 2013-01-01
Per Haag, Martin Andersson, Krister Nilner
{"title":"用两种贴面原理和两种烧成温度与钛结合的瓷。","authors":"Per Haag,&nbsp;Martin Andersson,&nbsp;Krister Nilner","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>Dental literature, as well as dental laboratories, has described problems with ceramic veneering of titanium, while clinical and in vitro studies have reported good results. The objective of this study was to investigate the effect of firing temperature, thermo cycling, and veneering methods on bond strength between porcelain and titanium. Eighty titanium specimens were prepared with one of two methods: a bonding agent firing or an oxidation firing. During veneering, half of the specimens in each group were fired at 30 degrees C above and half at the manufacturer's recommended temperature. In the bonding agent group and in the oxidation group, half of each firing group was thermocycled. Bond strength was calculated in a three-point bending test. Scanning electron microscopy (SEM) and energy dispersive X-ray spectroscopy (EDS) analyses of the titanium and the porcelain fracture surfaces of one specimen from each subgroup was used in order to study the composition of the interface between titanium and porcelain surfaces after fracture. No significant difference in bond strength was found when firing at a higher temperature compared with firing at the recommended temperature. An oxidation firing before veneering yielded significantly higher bond strength in a three-point bending test than when firing with a bonding agent. SEM and EDS analyses indicated a higher frequency of titanium oxide fractures in the oxidation than in the bonding agent group.The main finding is that firing at 30 degrees C above the recommended temperature does not significantly affect bond strength between titanium and porcelain. SEM and EDS analysis indicate that fractures occur in the titanium oxide layer by oxidation firing and in the interface between titanium oxide layer and veneering material by bonding agent firing.This finding might indicate that three- point bending test is not a relevant method for determining bond strength in this case, since the firing methods might influence the ductility of the samples.</p>","PeriodicalId":22114,"journal":{"name":"Swedish dental journal","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2013-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Porcelain bonding to titanium with two veneering principles and two firing temperatures.\",\"authors\":\"Per Haag,&nbsp;Martin Andersson,&nbsp;Krister Nilner\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Dental literature, as well as dental laboratories, has described problems with ceramic veneering of titanium, while clinical and in vitro studies have reported good results. The objective of this study was to investigate the effect of firing temperature, thermo cycling, and veneering methods on bond strength between porcelain and titanium. Eighty titanium specimens were prepared with one of two methods: a bonding agent firing or an oxidation firing. During veneering, half of the specimens in each group were fired at 30 degrees C above and half at the manufacturer's recommended temperature. In the bonding agent group and in the oxidation group, half of each firing group was thermocycled. Bond strength was calculated in a three-point bending test. Scanning electron microscopy (SEM) and energy dispersive X-ray spectroscopy (EDS) analyses of the titanium and the porcelain fracture surfaces of one specimen from each subgroup was used in order to study the composition of the interface between titanium and porcelain surfaces after fracture. No significant difference in bond strength was found when firing at a higher temperature compared with firing at the recommended temperature. An oxidation firing before veneering yielded significantly higher bond strength in a three-point bending test than when firing with a bonding agent. SEM and EDS analyses indicated a higher frequency of titanium oxide fractures in the oxidation than in the bonding agent group.The main finding is that firing at 30 degrees C above the recommended temperature does not significantly affect bond strength between titanium and porcelain. SEM and EDS analysis indicate that fractures occur in the titanium oxide layer by oxidation firing and in the interface between titanium oxide layer and veneering material by bonding agent firing.This finding might indicate that three- point bending test is not a relevant method for determining bond strength in this case, since the firing methods might influence the ductility of the samples.</p>\",\"PeriodicalId\":22114,\"journal\":{\"name\":\"Swedish dental journal\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2013-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Swedish dental journal\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q\",\"JCRName\":\"Dentistry\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Swedish dental journal","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q","JCRName":"Dentistry","Score":null,"Total":0}
引用次数: 0

摘要

牙科文献,以及牙科实验室,已经描述了钛陶瓷贴面的问题,而临床和体外研究报告了良好的结果。本研究的目的是探讨烧成温度、热循环和贴面方式对瓷与钛结合强度的影响。用两种方法中的一种制备了80个钛样品:粘结剂烧制或氧化烧制。在贴面过程中,每组中一半的试件在30℃以上的温度下烧制,另一半在制造商推荐的温度下烧制。在粘结剂组和氧化组中,各烧成组的一半进行热循环。在三点弯曲试验中计算了粘结强度。采用扫描电镜(SEM)和能谱仪(EDS)对各亚组各1个试样的钛和瓷断裂面进行了分析,研究了钛和瓷断裂面断裂后界面的组成。与在推荐温度下烧制相比,在更高温度下烧制时,粘结强度没有显着差异。在三点弯曲试验中,贴面前的氧化烧制比用粘结剂烧制得到了明显更高的粘结强度。扫描电镜(SEM)和能谱分析(EDS)表明,氧化组的氧化钛断裂频率高于粘结剂组。主要发现是,在比推荐温度高30摄氏度的温度下烧制不会显著影响钛和瓷器之间的结合强度。SEM和EDS分析表明,氧化烧成在氧化钛层内发生断裂,粘结剂烧成在氧化钛层与贴面材料界面处发生断裂。这一发现可能表明三点弯曲试验不是确定这种情况下粘结强度的相关方法,因为烧制方法可能会影响样品的延展性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Porcelain bonding to titanium with two veneering principles and two firing temperatures.

Dental literature, as well as dental laboratories, has described problems with ceramic veneering of titanium, while clinical and in vitro studies have reported good results. The objective of this study was to investigate the effect of firing temperature, thermo cycling, and veneering methods on bond strength between porcelain and titanium. Eighty titanium specimens were prepared with one of two methods: a bonding agent firing or an oxidation firing. During veneering, half of the specimens in each group were fired at 30 degrees C above and half at the manufacturer's recommended temperature. In the bonding agent group and in the oxidation group, half of each firing group was thermocycled. Bond strength was calculated in a three-point bending test. Scanning electron microscopy (SEM) and energy dispersive X-ray spectroscopy (EDS) analyses of the titanium and the porcelain fracture surfaces of one specimen from each subgroup was used in order to study the composition of the interface between titanium and porcelain surfaces after fracture. No significant difference in bond strength was found when firing at a higher temperature compared with firing at the recommended temperature. An oxidation firing before veneering yielded significantly higher bond strength in a three-point bending test than when firing with a bonding agent. SEM and EDS analyses indicated a higher frequency of titanium oxide fractures in the oxidation than in the bonding agent group.The main finding is that firing at 30 degrees C above the recommended temperature does not significantly affect bond strength between titanium and porcelain. SEM and EDS analysis indicate that fractures occur in the titanium oxide layer by oxidation firing and in the interface between titanium oxide layer and veneering material by bonding agent firing.This finding might indicate that three- point bending test is not a relevant method for determining bond strength in this case, since the firing methods might influence the ductility of the samples.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Swedish dental journal
Swedish dental journal 医学-牙科与口腔外科
CiteScore
0.85
自引率
0.00%
发文量
0
审稿时长
>12 weeks
期刊介绍: Swedish Dental Journal is the scientific journal of the Swedish Dental Association and the Swedish Dental Society. It is published 4 times a year to promote practice, education and research within odontology. Manuscripts containing original research are accepted for consideraion if neither the article nor any part of its essential substance has been or will be published elsewhere. Reviews, Case Reports and Short Communications will also be considered for publication.
期刊最新文献
Adverbs Verbs Punctuation Conjunctions Prepositions
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1