直接从一滴全血中测量趋化过程中中性粒细胞的速度和方向性。

Anh N Hoang, Caroline N Jones, Laurie Dimisko, Bashar Hamza, Joseph Martel, Nikola Kojic, Daniel Irimia
{"title":"直接从一滴全血中测量趋化过程中中性粒细胞的速度和方向性。","authors":"Anh N Hoang,&nbsp;Caroline N Jones,&nbsp;Laurie Dimisko,&nbsp;Bashar Hamza,&nbsp;Joseph Martel,&nbsp;Nikola Kojic,&nbsp;Daniel Irimia","doi":"10.1142/S2339547813500040","DOIUrl":null,"url":null,"abstract":"<p><p>Neutrophil chemotaxis is critical for defense against infections and its alterations could lead to chronic inflammation and tissue injury. The central role that transient alterations of neutrophil chemotaxis could have on patient outcomes calls for its quantification in the clinic. However, current methods for measuring neutrophil chemotaxis require large volumes of blood and are time consuming. To address the need for rapid and robust assays, we designed a microfluidic device that measures neutrophil chemotaxis directly from a single droplet of blood. We validated the assay by comparing neutrophil chemotaxis from finger prick, venous blood and purified neutrophil samples. We found consistent average velocity of (19 ± 6 μm/min) and directionality (91.1%) between the three sources. We quantified the variability in neutrophil chemotaxis between healthy donors and found no significant changes over time. We also validated the device in the clinic and documented temporary chemotaxis deficiencies after burn injuries.</p>","PeriodicalId":22332,"journal":{"name":"TECHNOLOGY","volume":"1 1","pages":"49"},"PeriodicalIF":0.0000,"publicationDate":"2013-10-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1142/S2339547813500040","citationCount":"44","resultStr":"{\"title\":\"Measuring neutrophil speed and directionality during chemotaxis, directly from a droplet of whole blood.\",\"authors\":\"Anh N Hoang,&nbsp;Caroline N Jones,&nbsp;Laurie Dimisko,&nbsp;Bashar Hamza,&nbsp;Joseph Martel,&nbsp;Nikola Kojic,&nbsp;Daniel Irimia\",\"doi\":\"10.1142/S2339547813500040\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Neutrophil chemotaxis is critical for defense against infections and its alterations could lead to chronic inflammation and tissue injury. The central role that transient alterations of neutrophil chemotaxis could have on patient outcomes calls for its quantification in the clinic. However, current methods for measuring neutrophil chemotaxis require large volumes of blood and are time consuming. To address the need for rapid and robust assays, we designed a microfluidic device that measures neutrophil chemotaxis directly from a single droplet of blood. We validated the assay by comparing neutrophil chemotaxis from finger prick, venous blood and purified neutrophil samples. We found consistent average velocity of (19 ± 6 μm/min) and directionality (91.1%) between the three sources. We quantified the variability in neutrophil chemotaxis between healthy donors and found no significant changes over time. We also validated the device in the clinic and documented temporary chemotaxis deficiencies after burn injuries.</p>\",\"PeriodicalId\":22332,\"journal\":{\"name\":\"TECHNOLOGY\",\"volume\":\"1 1\",\"pages\":\"49\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2013-10-02\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1142/S2339547813500040\",\"citationCount\":\"44\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"TECHNOLOGY\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1142/S2339547813500040\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"TECHNOLOGY","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1142/S2339547813500040","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 44

摘要

中性粒细胞趋化性是防御感染的关键,它的改变可能导致慢性炎症和组织损伤。中性粒细胞趋化性的短暂改变对患者预后的核心作用需要在临床中对其进行量化。然而,目前测量中性粒细胞趋化性的方法需要大量的血液,而且耗时。为了满足快速和可靠的检测需求,我们设计了一种微流体装置,可以直接从单滴血液中测量中性粒细胞趋化性。我们通过比较手指刺破、静脉血和纯化的中性粒细胞样本的中性粒细胞趋化性来验证该方法。结果表明,三个震源的平均速度(19±6 μm/min)和方向性(91.1%)一致。我们量化了健康供者之间中性粒细胞趋化性的可变性,并没有发现随时间的显著变化。我们还在临床验证了该装置,并记录了烧伤后暂时的趋化性缺陷。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

摘要图片

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Measuring neutrophil speed and directionality during chemotaxis, directly from a droplet of whole blood.

Neutrophil chemotaxis is critical for defense against infections and its alterations could lead to chronic inflammation and tissue injury. The central role that transient alterations of neutrophil chemotaxis could have on patient outcomes calls for its quantification in the clinic. However, current methods for measuring neutrophil chemotaxis require large volumes of blood and are time consuming. To address the need for rapid and robust assays, we designed a microfluidic device that measures neutrophil chemotaxis directly from a single droplet of blood. We validated the assay by comparing neutrophil chemotaxis from finger prick, venous blood and purified neutrophil samples. We found consistent average velocity of (19 ± 6 μm/min) and directionality (91.1%) between the three sources. We quantified the variability in neutrophil chemotaxis between healthy donors and found no significant changes over time. We also validated the device in the clinic and documented temporary chemotaxis deficiencies after burn injuries.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
TECHNOLOGY
TECHNOLOGY ENGINEERING, MULTIDISCIPLINARY-
自引率
0.00%
发文量
0
期刊最新文献
Twenty-four hour ex-vivo normothermic machine perfusion in rat livers. First-in-human evaluation of a hand-held automated venipuncture device for rapid venous blood draws. A protein interaction free energy model based on amino acid residue contributions: Assessment of point mutation stability of T4 lysozyme. The growing role of precision and personalized medicine for cancer treatment. Automated end-to-end blood testing at the point-of-care: Integration of robotic phlebotomy with downstream sample processing.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1