不同设计螺钉的轴向拉力比较:开窗螺钉、双外径螺钉和标准椎弓根螺钉。

Scoliosis Pub Date : 2015-05-01 eCollection Date: 2015-01-01 DOI:10.1186/s13013-015-0039-6
Evangelos Christodoulou, Suresh Chinthakunta, Divya Reddy, Saif Khalil, Thomas Apostolou, Philipp Drees, Konstantinos Kafchitsas
{"title":"不同设计螺钉的轴向拉力比较:开窗螺钉、双外径螺钉和标准椎弓根螺钉。","authors":"Evangelos Christodoulou,&nbsp;Suresh Chinthakunta,&nbsp;Divya Reddy,&nbsp;Saif Khalil,&nbsp;Thomas Apostolou,&nbsp;Philipp Drees,&nbsp;Konstantinos Kafchitsas","doi":"10.1186/s13013-015-0039-6","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>The pullout strength of pedicle screws is influenced by many factors, including diameter of the screws, implant design, and augmentation with bone cement such as PMMA. In the present study, the pullout strength of an innovative fenestrated screw augmented with PMMA was investigated and was compared to unaugmented fenestrated, standard and dual outer diameter screw.</p><p><strong>Methods: </strong>Twenty four thoracolumbar vertebrae (T10-L5, age 60 to 70 years) from three cadavers were implanted with the four different pedicle screws. Twelve screws of each type were instrumented into either left or right pedicle with standard screw paired with unaugmented and dual outer diameter screw paired with augmented fenestrated screw in any given vertebra. Axial pullout testing was conducted at a rate of 5 mm/min. Force to failure (Newtons) for each pedicle screw was recorded.</p><p><strong>Results: </strong>The augmented fenestrated screws had the highest pullout strength, which represented an average increase of 149%, 141%, and 78% in comparison to unaugmented, standard, and dual outer diameter screws, respectively. Pullout strength of unaugmented screws was comparable to that of standard screws, however it was significantly lower than dual outer diameter screws.</p><p><strong>Conclusions: </strong>Fenestrated screws augmented with PMMA improve the fixation strength and result in significantly higher pullout strength compared to dual outer diameter, standard and unaugmented fenestrated screws. Screws with dual outer diameter provided enhanced bone-screw purchase and may be considered as an alternative technique to increase the bone-screw interface in cases where augmentation using bone cement is not feasible. Unaugmented screws can be left in the pedicle even without cement and provide similar pullout strength to standard screws.</p>","PeriodicalId":21722,"journal":{"name":"Scoliosis","volume":"10 ","pages":"15"},"PeriodicalIF":0.0000,"publicationDate":"2015-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1186/s13013-015-0039-6","citationCount":"21","resultStr":"{\"title\":\"Axial pullout strength comparison of different screw designs: fenestrated screw, dual outer diameter screw and standard pedicle screw.\",\"authors\":\"Evangelos Christodoulou,&nbsp;Suresh Chinthakunta,&nbsp;Divya Reddy,&nbsp;Saif Khalil,&nbsp;Thomas Apostolou,&nbsp;Philipp Drees,&nbsp;Konstantinos Kafchitsas\",\"doi\":\"10.1186/s13013-015-0039-6\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>The pullout strength of pedicle screws is influenced by many factors, including diameter of the screws, implant design, and augmentation with bone cement such as PMMA. In the present study, the pullout strength of an innovative fenestrated screw augmented with PMMA was investigated and was compared to unaugmented fenestrated, standard and dual outer diameter screw.</p><p><strong>Methods: </strong>Twenty four thoracolumbar vertebrae (T10-L5, age 60 to 70 years) from three cadavers were implanted with the four different pedicle screws. Twelve screws of each type were instrumented into either left or right pedicle with standard screw paired with unaugmented and dual outer diameter screw paired with augmented fenestrated screw in any given vertebra. Axial pullout testing was conducted at a rate of 5 mm/min. Force to failure (Newtons) for each pedicle screw was recorded.</p><p><strong>Results: </strong>The augmented fenestrated screws had the highest pullout strength, which represented an average increase of 149%, 141%, and 78% in comparison to unaugmented, standard, and dual outer diameter screws, respectively. Pullout strength of unaugmented screws was comparable to that of standard screws, however it was significantly lower than dual outer diameter screws.</p><p><strong>Conclusions: </strong>Fenestrated screws augmented with PMMA improve the fixation strength and result in significantly higher pullout strength compared to dual outer diameter, standard and unaugmented fenestrated screws. Screws with dual outer diameter provided enhanced bone-screw purchase and may be considered as an alternative technique to increase the bone-screw interface in cases where augmentation using bone cement is not feasible. Unaugmented screws can be left in the pedicle even without cement and provide similar pullout strength to standard screws.</p>\",\"PeriodicalId\":21722,\"journal\":{\"name\":\"Scoliosis\",\"volume\":\"10 \",\"pages\":\"15\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-05-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1186/s13013-015-0039-6\",\"citationCount\":\"21\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Scoliosis\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1186/s13013-015-0039-6\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2015/1/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Scoliosis","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1186/s13013-015-0039-6","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2015/1/1 0:00:00","PubModel":"eCollection","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 21

摘要

背景:椎弓根螺钉的拔出强度受多种因素的影响,包括螺钉直径、种植体设计、PMMA等骨水泥增强等。在本研究中,研究了一种新型的PMMA增加的开孔螺钉的拉拔强度,并与未增加的开孔螺钉、标准螺钉和双外径螺钉进行了比较。方法:选取3具尸体24块胸腰椎(T10-L5,年龄60 ~ 70岁),植入4种不同的椎弓根螺钉。将每种类型的12颗螺钉分别置入任意椎体的左椎弓根或右椎弓根,标准螺钉与未扩大的螺钉配对,双外径螺钉与扩大的开孔螺钉配对。轴向拉拔试验以5 mm/min的速率进行。记录每个椎弓根螺钉的失效力(牛顿)。结果:增加的开窗螺钉具有最高的拉出强度,与未增加、标准和双外径螺钉相比,分别平均增加149%、141%和78%。非增径螺钉的拉拔强度与标准螺钉相当,但明显低于双外径螺钉。结论:与双外径、标准和未增强的开孔螺钉相比,PMMA增强的开孔螺钉提高了固定强度,拔出强度显著提高。双外径螺钉增强了骨螺钉的购买量,在无法使用骨水泥进行增强的情况下,可将其视为增加骨螺钉界面的替代技术。即使没有骨水泥,未增强螺钉也可以留在椎弓根内,并提供与标准螺钉相似的拉出强度。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

摘要图片

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Axial pullout strength comparison of different screw designs: fenestrated screw, dual outer diameter screw and standard pedicle screw.

Background: The pullout strength of pedicle screws is influenced by many factors, including diameter of the screws, implant design, and augmentation with bone cement such as PMMA. In the present study, the pullout strength of an innovative fenestrated screw augmented with PMMA was investigated and was compared to unaugmented fenestrated, standard and dual outer diameter screw.

Methods: Twenty four thoracolumbar vertebrae (T10-L5, age 60 to 70 years) from three cadavers were implanted with the four different pedicle screws. Twelve screws of each type were instrumented into either left or right pedicle with standard screw paired with unaugmented and dual outer diameter screw paired with augmented fenestrated screw in any given vertebra. Axial pullout testing was conducted at a rate of 5 mm/min. Force to failure (Newtons) for each pedicle screw was recorded.

Results: The augmented fenestrated screws had the highest pullout strength, which represented an average increase of 149%, 141%, and 78% in comparison to unaugmented, standard, and dual outer diameter screws, respectively. Pullout strength of unaugmented screws was comparable to that of standard screws, however it was significantly lower than dual outer diameter screws.

Conclusions: Fenestrated screws augmented with PMMA improve the fixation strength and result in significantly higher pullout strength compared to dual outer diameter, standard and unaugmented fenestrated screws. Screws with dual outer diameter provided enhanced bone-screw purchase and may be considered as an alternative technique to increase the bone-screw interface in cases where augmentation using bone cement is not feasible. Unaugmented screws can be left in the pedicle even without cement and provide similar pullout strength to standard screws.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Gravity-induced coronal plane joint moments in adolescent idiopathic scoliosis Retraction Note: Relationship between bone density and bone metabolism in adolescent idiopathic scoliosis Fasting total ghrelin levels are increased in patients with adolescent idiopathic scoliosis Early weaning in idiopathic scoliosis Post-operative shoulder imbalance in adolescent idiopathic scoliosis: a study of clinical photographs
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1