海藻酸钙凝胶作为大鼠离体皮肤交流电离子导入利多卡因电极材料的评价。

Q4 Dentistry Journal of Medical and Dental Sciences Pub Date : 2014-06-27 DOI:10.11480/610201
Tomoko Ebisawa, Atsushi Nakajima, Haruka Haida, Ryo Wakita, Shizuka Ando, Tomohiko Yoshioka, Toshiyuki Ikoma, Junzo Tanaka, Haruhisa Fukayama
{"title":"海藻酸钙凝胶作为大鼠离体皮肤交流电离子导入利多卡因电极材料的评价。","authors":"Tomoko Ebisawa,&nbsp;Atsushi Nakajima,&nbsp;Haruka Haida,&nbsp;Ryo Wakita,&nbsp;Shizuka Ando,&nbsp;Tomohiko Yoshioka,&nbsp;Toshiyuki Ikoma,&nbsp;Junzo Tanaka,&nbsp;Haruhisa Fukayama","doi":"10.11480/610201","DOIUrl":null,"url":null,"abstract":"<p><p>Iontophoresis (IOP) is a noninvasive method of delivering medication transcutaneously through the skin. The electrodes used in this method should tightly fit to rough and irregular surfaces and be biologically safe, easy to handle and prepare, and cost-effective. To satisfy these requirements, calcium alginate gel can be a candidate electrode for IOP. Using calcium alginate gel electrodes, we examined whether lidocaine can be effectively transported across an excised rat skin by squarewave alternating current (AC) application. A squarewave AC with either a 70% or 80% duty cycle was continuously applied to 0.5% calcium alginate gel electrodes containing 10% lidocaine at 10 V and 1 kHz for 60 min. Lidocaine concentration was measured using a spectrophotometer and the temperature of the gel was determined. The lidocaine concentrations for AC-IOP at the 70% and 80% duty cycles were significantly higher than that without AC-IOP. Furthermore, the group with the 80% duty cycle showed higher lidocaine concentrations than the group with the 70% duty cycle. The temperatures of all the groups were lower than 28 °C throughout the procedure. In conclusion, the calcium alginate gel can be used as a possible matrix for IOP electrodes.</p>","PeriodicalId":39643,"journal":{"name":"Journal of Medical and Dental Sciences","volume":"61 2","pages":"41-8"},"PeriodicalIF":0.0000,"publicationDate":"2014-06-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.11480/610201","citationCount":"3","resultStr":"{\"title\":\"Evaluation of calcium alginate gel as electrode material for alternating current iontophoresis of lidocaine using excised rat skin.\",\"authors\":\"Tomoko Ebisawa,&nbsp;Atsushi Nakajima,&nbsp;Haruka Haida,&nbsp;Ryo Wakita,&nbsp;Shizuka Ando,&nbsp;Tomohiko Yoshioka,&nbsp;Toshiyuki Ikoma,&nbsp;Junzo Tanaka,&nbsp;Haruhisa Fukayama\",\"doi\":\"10.11480/610201\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Iontophoresis (IOP) is a noninvasive method of delivering medication transcutaneously through the skin. The electrodes used in this method should tightly fit to rough and irregular surfaces and be biologically safe, easy to handle and prepare, and cost-effective. To satisfy these requirements, calcium alginate gel can be a candidate electrode for IOP. Using calcium alginate gel electrodes, we examined whether lidocaine can be effectively transported across an excised rat skin by squarewave alternating current (AC) application. A squarewave AC with either a 70% or 80% duty cycle was continuously applied to 0.5% calcium alginate gel electrodes containing 10% lidocaine at 10 V and 1 kHz for 60 min. Lidocaine concentration was measured using a spectrophotometer and the temperature of the gel was determined. The lidocaine concentrations for AC-IOP at the 70% and 80% duty cycles were significantly higher than that without AC-IOP. Furthermore, the group with the 80% duty cycle showed higher lidocaine concentrations than the group with the 70% duty cycle. The temperatures of all the groups were lower than 28 °C throughout the procedure. In conclusion, the calcium alginate gel can be used as a possible matrix for IOP electrodes.</p>\",\"PeriodicalId\":39643,\"journal\":{\"name\":\"Journal of Medical and Dental Sciences\",\"volume\":\"61 2\",\"pages\":\"41-8\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2014-06-27\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.11480/610201\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Medical and Dental Sciences\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.11480/610201\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"Dentistry\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Medical and Dental Sciences","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.11480/610201","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Dentistry","Score":null,"Total":0}
引用次数: 3

摘要

离子透入(IOP)是一种通过皮肤经皮给药的非侵入性方法。在这种方法中使用的电极应紧密适合粗糙和不规则的表面,生物安全,易于处理和准备,并具有成本效益。为了满足这些要求,海藻酸钙凝胶可以作为IOP的候选电极。使用海藻酸钙凝胶电极,我们检测了利多卡因是否可以通过方波交流电(AC)有效地通过切除的大鼠皮肤传输。将占空比为70%或80%的方波交流电连续施加于含有10%利多卡因的0.5%海藻酸钙凝胶电极上,电压为10 V,频率为1 kHz,持续60分钟。用分光光度计测量利多卡因浓度,并测定凝胶温度。70%和80%占空比时AC-IOP组利多卡因浓度显著高于无AC-IOP组。此外,80%占空比组的利多卡因浓度高于70%占空比组。在整个过程中,所有组的温度都低于28℃。综上所述,海藻酸钙凝胶可以作为IOP电极的可能基质。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Evaluation of calcium alginate gel as electrode material for alternating current iontophoresis of lidocaine using excised rat skin.

Iontophoresis (IOP) is a noninvasive method of delivering medication transcutaneously through the skin. The electrodes used in this method should tightly fit to rough and irregular surfaces and be biologically safe, easy to handle and prepare, and cost-effective. To satisfy these requirements, calcium alginate gel can be a candidate electrode for IOP. Using calcium alginate gel electrodes, we examined whether lidocaine can be effectively transported across an excised rat skin by squarewave alternating current (AC) application. A squarewave AC with either a 70% or 80% duty cycle was continuously applied to 0.5% calcium alginate gel electrodes containing 10% lidocaine at 10 V and 1 kHz for 60 min. Lidocaine concentration was measured using a spectrophotometer and the temperature of the gel was determined. The lidocaine concentrations for AC-IOP at the 70% and 80% duty cycles were significantly higher than that without AC-IOP. Furthermore, the group with the 80% duty cycle showed higher lidocaine concentrations than the group with the 70% duty cycle. The temperatures of all the groups were lower than 28 °C throughout the procedure. In conclusion, the calcium alginate gel can be used as a possible matrix for IOP electrodes.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Medical and Dental Sciences
Journal of Medical and Dental Sciences Dentistry-Dentistry (all)
CiteScore
0.30
自引率
0.00%
发文量
0
期刊介绍: "Journal of Medical and Dental Sciences" publishes the results of research conducted at Tokyo Medical and Dental University. The journal made its first appearance in 1954. We issue four numbers by the year.
期刊最新文献
Including clinic-based English education in dental curriculum, supplemented by e-learning Chronic sun exposure shortens telomeres of the epidermis Relationship between taste sensitivity and dental caries MICROROBOTICS IN ENDODONTICS – A REVIEW “FUNCTIONAL ORTHOPAEDICS” USED IN YOUNG GROWING INDIVIDUALS FOR CORRECTION OF SKELETAL CLASS II MALOCCLUSION: - MOST RELIABLE METHOD
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1