Maria L Kafetzi, Aliki G Iniotaki, George C Liapis, Maria N Darema, Ilias I N Doxiadis, John N Boletis
{"title":"针对内皮前细胞的IgM抗体:与加速排斥反应相关的强烈迹象。一份病例报告。","authors":"Maria L Kafetzi, Aliki G Iniotaki, George C Liapis, Maria N Darema, Ilias I N Doxiadis, John N Boletis","doi":"10.1093/ndtplus/sfr147","DOIUrl":null,"url":null,"abstract":"<p><p>A 27-year-old woman developed a graft loss due to an accelerated humoral rejection after receiving a blood group identical, human leucocyte antigens (HLA) haploidentical living-related kidney, despite the fact that she did not refer any sensitization event before transplantation. The complement-dependent cytotoxicity and flow cytometry crossmatches were negative for T and B cells. Retrospectively, IgM antibodies against donor precursor endothelial Tie-2(+) cells were detected using a commercially available assay and the pre-transplant serum sample. This case illustrates the necessity of detection of other than the classical HLA-directed antibodies prior organ grafting. </p>","PeriodicalId":18987,"journal":{"name":"NDT Plus","volume":"4 6","pages":"416-7"},"PeriodicalIF":0.0000,"publicationDate":"2011-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1093/ndtplus/sfr147","citationCount":"2","resultStr":"{\"title\":\"IgM antibodies towards pre-endothelial cells: strong indication for an association with accelerated rejection. A case report.\",\"authors\":\"Maria L Kafetzi, Aliki G Iniotaki, George C Liapis, Maria N Darema, Ilias I N Doxiadis, John N Boletis\",\"doi\":\"10.1093/ndtplus/sfr147\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>A 27-year-old woman developed a graft loss due to an accelerated humoral rejection after receiving a blood group identical, human leucocyte antigens (HLA) haploidentical living-related kidney, despite the fact that she did not refer any sensitization event before transplantation. The complement-dependent cytotoxicity and flow cytometry crossmatches were negative for T and B cells. Retrospectively, IgM antibodies against donor precursor endothelial Tie-2(+) cells were detected using a commercially available assay and the pre-transplant serum sample. This case illustrates the necessity of detection of other than the classical HLA-directed antibodies prior organ grafting. </p>\",\"PeriodicalId\":18987,\"journal\":{\"name\":\"NDT Plus\",\"volume\":\"4 6\",\"pages\":\"416-7\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2011-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1093/ndtplus/sfr147\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"NDT Plus\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1093/ndtplus/sfr147\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"NDT Plus","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1093/ndtplus/sfr147","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
IgM antibodies towards pre-endothelial cells: strong indication for an association with accelerated rejection. A case report.
A 27-year-old woman developed a graft loss due to an accelerated humoral rejection after receiving a blood group identical, human leucocyte antigens (HLA) haploidentical living-related kidney, despite the fact that she did not refer any sensitization event before transplantation. The complement-dependent cytotoxicity and flow cytometry crossmatches were negative for T and B cells. Retrospectively, IgM antibodies against donor precursor endothelial Tie-2(+) cells were detected using a commercially available assay and the pre-transplant serum sample. This case illustrates the necessity of detection of other than the classical HLA-directed antibodies prior organ grafting.