对比增强3D-STIR-VISTA在臂丛磁共振成像中的应用。

IF 2 4区 医学 Q4 Medicine Journal of the Belgian Society of Radiology Pub Date : 2022-09-05 eCollection Date: 2022-01-01 DOI:10.5334/jbsr.2803
Dingsheng Han, Yanru Zhou, Lan Zhang, Jiajia Zhang
{"title":"对比增强3D-STIR-VISTA在臂丛磁共振成像中的应用。","authors":"Dingsheng Han,&nbsp;Yanru Zhou,&nbsp;Lan Zhang,&nbsp;Jiajia Zhang","doi":"10.5334/jbsr.2803","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>To introduce contrast-enhanced 3D-STIR-VISTA sequence that would improve the image quality for the brachial plexus imaging and enhance the contrast between the brachial plexus and surrounding tissues.</p><p><strong>Methods: </strong>Thirty subjects (average age, 47.33 ± 15.15 years; 22 males and 8 females) were enrolled, including 7 patients with brachial plexus injuries, 4 patients with schwannomas, 1 patient with neurofibroma, 1 patient with thoracic outlet syndrome, 1 patient with metastasis, 1 patient with brachial plexus neuritis, and 15 patients without abnormal findings. Scores of unenhanced and contrast-enhanced 3D-STIR-VISTA images using a 5-point scale were compared by Wilcoxon's signed-rank test. The signal intensity (SI), signal to noise ratio (SNR), contrast to noise ratio (CNR) and contrast ratio (CR) between 3D-STIR-VISTA images without and with contrast agent were compared by the paired Student t-test.</p><p><strong>Results: </strong>The SNRs of the brachial plexus between 3D-STIR-VISTA without and with contrast agent were not significantly different, while SNRs of surrounding tissues were significantly decreased with contrast agent. The CNRs of 3D-STIR-VISTA images with contrast agent were significantly higher than that without contrast agent. The 3D-STIR-VISTA sequence with contrast agent exhibited a statistically higher CR than that without contrast agent. The average score for 3D-STIR-VISTA images with contrast agent was significantly higher than that without contrast agent.</p><p><strong>Conclusion: </strong>The 3D-STIR-VISTA sequence with contrast agent is qualitatively and quantitatively superior to that without a contrast agent. The contrast-enhanced 3D-STIR-VISTA sequence can provide distinct visualization of the brachial plexus and enhance the contrast between the brachial plexus and surrounding tissues.</p>","PeriodicalId":56282,"journal":{"name":"Journal of the Belgian Society of Radiology","volume":null,"pages":null},"PeriodicalIF":2.0000,"publicationDate":"2022-09-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9461682/pdf/","citationCount":"0","resultStr":"{\"title\":\"The Application of Contrast-Enhanced 3D-STIR-VISTA MR Imaging of the Brachial Plexus.\",\"authors\":\"Dingsheng Han,&nbsp;Yanru Zhou,&nbsp;Lan Zhang,&nbsp;Jiajia Zhang\",\"doi\":\"10.5334/jbsr.2803\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objective: </strong>To introduce contrast-enhanced 3D-STIR-VISTA sequence that would improve the image quality for the brachial plexus imaging and enhance the contrast between the brachial plexus and surrounding tissues.</p><p><strong>Methods: </strong>Thirty subjects (average age, 47.33 ± 15.15 years; 22 males and 8 females) were enrolled, including 7 patients with brachial plexus injuries, 4 patients with schwannomas, 1 patient with neurofibroma, 1 patient with thoracic outlet syndrome, 1 patient with metastasis, 1 patient with brachial plexus neuritis, and 15 patients without abnormal findings. Scores of unenhanced and contrast-enhanced 3D-STIR-VISTA images using a 5-point scale were compared by Wilcoxon's signed-rank test. The signal intensity (SI), signal to noise ratio (SNR), contrast to noise ratio (CNR) and contrast ratio (CR) between 3D-STIR-VISTA images without and with contrast agent were compared by the paired Student t-test.</p><p><strong>Results: </strong>The SNRs of the brachial plexus between 3D-STIR-VISTA without and with contrast agent were not significantly different, while SNRs of surrounding tissues were significantly decreased with contrast agent. The CNRs of 3D-STIR-VISTA images with contrast agent were significantly higher than that without contrast agent. The 3D-STIR-VISTA sequence with contrast agent exhibited a statistically higher CR than that without contrast agent. The average score for 3D-STIR-VISTA images with contrast agent was significantly higher than that without contrast agent.</p><p><strong>Conclusion: </strong>The 3D-STIR-VISTA sequence with contrast agent is qualitatively and quantitatively superior to that without a contrast agent. The contrast-enhanced 3D-STIR-VISTA sequence can provide distinct visualization of the brachial plexus and enhance the contrast between the brachial plexus and surrounding tissues.</p>\",\"PeriodicalId\":56282,\"journal\":{\"name\":\"Journal of the Belgian Society of Radiology\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":2.0000,\"publicationDate\":\"2022-09-05\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9461682/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of the Belgian Society of Radiology\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.5334/jbsr.2803\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2022/1/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"Q4\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of the Belgian Society of Radiology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.5334/jbsr.2803","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2022/1/1 0:00:00","PubModel":"eCollection","JCR":"Q4","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

摘要

目的:介绍增强3D-STIR-VISTA序列,提高臂丛成像的图像质量,增强臂丛与周围组织的对比度。方法:30例受试者,平均年龄47.33±15.15岁;其中臂丛神经损伤患者7例,神经鞘瘤患者4例,神经纤维瘤患者1例,胸廓出口综合征患者1例,转移患者1例,臂丛神经炎患者1例,无异常患者15例。使用5分制比较未增强和对比度增强的3D-STIR-VISTA图像的分数,采用Wilcoxon's signed-rank检验。采用配对学生t检验比较未添加和添加造影剂的3D-STIR-VISTA图像的信号强度(SI)、信噪比(SNR)、噪比(CNR)和对比度(CR)。结果:3D-STIR-VISTA未加对比剂与加对比剂前后臂丛的信噪比无显著差异,而加对比剂后臂丛周围组织的信噪比明显降低。添加造影剂后3D-STIR-VISTA图像的cnr明显高于未添加造影剂的图像。有造影剂的3D-STIR-VISTA序列比没有造影剂的CR有统计学意义上更高。使用造影剂的3D-STIR-VISTA图像的平均评分明显高于未使用造影剂的3D-STIR-VISTA图像。结论:有造影剂的3D-STIR-VISTA序列在定性和定量上均优于未加造影剂的3D-STIR-VISTA序列。增强3D-STIR-VISTA序列能清晰显示臂丛,增强臂丛与周围组织的对比。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

摘要图片

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
The Application of Contrast-Enhanced 3D-STIR-VISTA MR Imaging of the Brachial Plexus.

Objective: To introduce contrast-enhanced 3D-STIR-VISTA sequence that would improve the image quality for the brachial plexus imaging and enhance the contrast between the brachial plexus and surrounding tissues.

Methods: Thirty subjects (average age, 47.33 ± 15.15 years; 22 males and 8 females) were enrolled, including 7 patients with brachial plexus injuries, 4 patients with schwannomas, 1 patient with neurofibroma, 1 patient with thoracic outlet syndrome, 1 patient with metastasis, 1 patient with brachial plexus neuritis, and 15 patients without abnormal findings. Scores of unenhanced and contrast-enhanced 3D-STIR-VISTA images using a 5-point scale were compared by Wilcoxon's signed-rank test. The signal intensity (SI), signal to noise ratio (SNR), contrast to noise ratio (CNR) and contrast ratio (CR) between 3D-STIR-VISTA images without and with contrast agent were compared by the paired Student t-test.

Results: The SNRs of the brachial plexus between 3D-STIR-VISTA without and with contrast agent were not significantly different, while SNRs of surrounding tissues were significantly decreased with contrast agent. The CNRs of 3D-STIR-VISTA images with contrast agent were significantly higher than that without contrast agent. The 3D-STIR-VISTA sequence with contrast agent exhibited a statistically higher CR than that without contrast agent. The average score for 3D-STIR-VISTA images with contrast agent was significantly higher than that without contrast agent.

Conclusion: The 3D-STIR-VISTA sequence with contrast agent is qualitatively and quantitatively superior to that without a contrast agent. The contrast-enhanced 3D-STIR-VISTA sequence can provide distinct visualization of the brachial plexus and enhance the contrast between the brachial plexus and surrounding tissues.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of the Belgian Society of Radiology
Journal of the Belgian Society of Radiology Medicine-Radiology, Nuclear Medicine and Imaging
CiteScore
0.60
自引率
5.00%
发文量
0
审稿时长
6-12 weeks
期刊介绍: The purpose of the Journal of the Belgian Society of Radiology is the publication of articles dealing with diagnostic and interventional radiology, related imaging techniques, allied sciences, and continuing education.
期刊最新文献
Invisible Active Bleeding Due to the Watershed Phenomenon Low Consciousness in a Patient with Pancolitis Myositis Ossificans: A Mimicker of an Intramuscular Tumour Xanthogranulomatous and Emphysematous Pyelonephritis: Two Rare Entities Occurring in One Kidney A Rare Presentation of Polypoid Endometriosis of the Douglas Pouch: Case Report
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1