生物识别系统:心电图高斯性和数据合成。

Wael Louis, Shahad Abdulnour, Sahar Javaher Haghighi, Dimitrios Hatzinakos
{"title":"生物识别系统:心电图高斯性和数据合成。","authors":"Wael Louis,&nbsp;Shahad Abdulnour,&nbsp;Sahar Javaher Haghighi,&nbsp;Dimitrios Hatzinakos","doi":"10.1186/s13637-017-0056-2","DOIUrl":null,"url":null,"abstract":"<p><p>Electrocardiogram is a slow signal to acquire, and it is prone to noise. It can be inconvenient to collect large number of ECG heartbeats in order to train a reliable biometric system; hence, this issue might result in a small sample size phenomenon which occurs when the number of samples is much smaller than the number of observations to model. In this paper, we study ECG heartbeat Gaussianity and we generate synthesized data to increase the number of observations. Data synthesis, in this paper, is based on our hypothesis, which we support, that ECG heartbeats exhibit a multivariate normal distribution; therefore, one can generate ECG heartbeats from such distribution. This distribution is deviated from Gaussianity due to internal and external factors that change ECG morphology such as noise, diet, physical and psychological changes, and other factors, but we attempt to capture the underlying Gaussianity of the heartbeats. When this method was implemented for a biometric system and was examined on the University of Toronto database of 1012 subjects, an equal error rate (EER) of 6.71% was achieved in comparison to 9.35% to the same system but without data synthesis. Dimensionality reduction is widely examined in the problem of small sample size; however, our results suggest that using the proposed data synthesis outperformed several dimensionality reduction techniques by at least 3.21% in EER. With small sample size, classifier instability becomes a bigger issue and we used a parallel classifier scheme to reduce it. Each classifier in the parallel classifier is trained with the same genuine dataset but different imposter datasets. The parallel classifier has reduced predictors' true acceptance rate instability from 6.52% standard deviation to 1.94% standard deviation.</p>","PeriodicalId":72957,"journal":{"name":"EURASIP journal on bioinformatics & systems biology","volume":"2017 1","pages":"5"},"PeriodicalIF":0.0000,"publicationDate":"2017-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1186/s13637-017-0056-2","citationCount":"2","resultStr":"{\"title\":\"On biometric systems: electrocardiogram Gaussianity and data synthesis.\",\"authors\":\"Wael Louis,&nbsp;Shahad Abdulnour,&nbsp;Sahar Javaher Haghighi,&nbsp;Dimitrios Hatzinakos\",\"doi\":\"10.1186/s13637-017-0056-2\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Electrocardiogram is a slow signal to acquire, and it is prone to noise. It can be inconvenient to collect large number of ECG heartbeats in order to train a reliable biometric system; hence, this issue might result in a small sample size phenomenon which occurs when the number of samples is much smaller than the number of observations to model. In this paper, we study ECG heartbeat Gaussianity and we generate synthesized data to increase the number of observations. Data synthesis, in this paper, is based on our hypothesis, which we support, that ECG heartbeats exhibit a multivariate normal distribution; therefore, one can generate ECG heartbeats from such distribution. This distribution is deviated from Gaussianity due to internal and external factors that change ECG morphology such as noise, diet, physical and psychological changes, and other factors, but we attempt to capture the underlying Gaussianity of the heartbeats. When this method was implemented for a biometric system and was examined on the University of Toronto database of 1012 subjects, an equal error rate (EER) of 6.71% was achieved in comparison to 9.35% to the same system but without data synthesis. Dimensionality reduction is widely examined in the problem of small sample size; however, our results suggest that using the proposed data synthesis outperformed several dimensionality reduction techniques by at least 3.21% in EER. With small sample size, classifier instability becomes a bigger issue and we used a parallel classifier scheme to reduce it. Each classifier in the parallel classifier is trained with the same genuine dataset but different imposter datasets. The parallel classifier has reduced predictors' true acceptance rate instability from 6.52% standard deviation to 1.94% standard deviation.</p>\",\"PeriodicalId\":72957,\"journal\":{\"name\":\"EURASIP journal on bioinformatics & systems biology\",\"volume\":\"2017 1\",\"pages\":\"5\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2017-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1186/s13637-017-0056-2\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"EURASIP journal on bioinformatics & systems biology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1186/s13637-017-0056-2\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2017/2/21 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"EURASIP journal on bioinformatics & systems biology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1186/s13637-017-0056-2","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2017/2/21 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

心电图是一种缓慢的信号,而且容易产生噪声。为了训练可靠的生物识别系统,采集大量心电心跳数据不方便;因此,这个问题可能会导致小样本现象,当样本数量远远小于要建模的观测数量时,就会发生这种现象。在本文中,我们研究了心电心跳的高斯性,并生成了合成数据来增加观测的数量。本文的数据合成基于我们的假设,我们支持该假设,即心电心跳呈现多元正态分布;因此,人们可以从这种分布中产生心电心跳。由于改变心电图形态的内部和外部因素(如噪音、饮食、身体和心理变化以及其他因素),这种分布偏离了高斯性,但我们试图捕捉心跳的潜在高斯性。将该方法应用于一个生物识别系统,并在多伦多大学1012名受试者的数据库中进行了测试,结果表明,该方法的错误率(EER)为6.71%,而在没有数据合成的情况下,该系统的错误率为9.35%。在小样本量问题中,降维问题被广泛研究;然而,我们的研究结果表明,使用所提出的数据合成技术在EER方面的表现至少优于几种降维技术3.21%。在小样本量的情况下,分类器的不稳定性成为一个更大的问题,我们使用并行分类器方案来减少它。并行分类器中的每个分类器都使用相同的真实数据集和不同的冒名顶替数据集进行训练。并行分类器将预测器的真实接受率不稳定性从6.52%标准差降低到1.94%标准差。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
On biometric systems: electrocardiogram Gaussianity and data synthesis.

Electrocardiogram is a slow signal to acquire, and it is prone to noise. It can be inconvenient to collect large number of ECG heartbeats in order to train a reliable biometric system; hence, this issue might result in a small sample size phenomenon which occurs when the number of samples is much smaller than the number of observations to model. In this paper, we study ECG heartbeat Gaussianity and we generate synthesized data to increase the number of observations. Data synthesis, in this paper, is based on our hypothesis, which we support, that ECG heartbeats exhibit a multivariate normal distribution; therefore, one can generate ECG heartbeats from such distribution. This distribution is deviated from Gaussianity due to internal and external factors that change ECG morphology such as noise, diet, physical and psychological changes, and other factors, but we attempt to capture the underlying Gaussianity of the heartbeats. When this method was implemented for a biometric system and was examined on the University of Toronto database of 1012 subjects, an equal error rate (EER) of 6.71% was achieved in comparison to 9.35% to the same system but without data synthesis. Dimensionality reduction is widely examined in the problem of small sample size; however, our results suggest that using the proposed data synthesis outperformed several dimensionality reduction techniques by at least 3.21% in EER. With small sample size, classifier instability becomes a bigger issue and we used a parallel classifier scheme to reduce it. Each classifier in the parallel classifier is trained with the same genuine dataset but different imposter datasets. The parallel classifier has reduced predictors' true acceptance rate instability from 6.52% standard deviation to 1.94% standard deviation.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
From protein-protein interactions to protein co-expression networks: a new perspective to evaluate large-scale proteomic data. On biometric systems: electrocardiogram Gaussianity and data synthesis. BCC-NER: bidirectional, contextual clues named entity tagger for gene/protein mention recognition. Review of stochastic hybrid systems with applications in biological systems modeling and analysis. Bayesian inference for biomarker discovery in proteomics: an analytic solution.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1