[在乳房碎裂和割伤伤口上矫治流变性血液的可能性]。

V V Masljakov, O A Suhanova, V G Barsukov, K G Kurkin, S A Suhanov
{"title":"[在乳房碎裂和割伤伤口上矫治流变性血液的可能性]。","authors":"V V Masljakov,&nbsp;O A Suhanova,&nbsp;V G Barsukov,&nbsp;K G Kurkin,&nbsp;S A Suhanov","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>The purpose: research objective: to study influence of electromagnetic oscillations of millimetric range on rheological properties of blood at patients with chipped and cut wounds of a breast for the purpose of their correction. Methods. For the solution of a research objective we have carried out studying of changes of rheological properties of blood at the 22nd patient with the getting chipped and cut wounds of a breast without internal injury during the next postoperative period. All patient has executed primary surgical processing and drainage of a pleural cavity. At all patients the volume of blood loss has made 200-500 ml. Criteria of inclusion were: existence of the getting wound of a thorax, existence of a small gemotoraks. Criteria of an exception: blood loss existence more than 500 ml, existence of the combined and multiple damages. The main group is divided into two subgroups, in the first 12 patients with application of electromagnetic oscillations of millimetric range, have entered the second 10 people without application of electromagnetic oscillations of millimetric range. The group of comparison was made by 15 rather healthy donor volunteers of the same age and a floor. To all patients the hemotransfusion wasn’t carried out, the volume of infusional therapy was comparable in both groups. Changes of a rheology of blood came to light by means of the accounting of viscosity of blood, change of an index of deformation and aggregation of erythrocytes. Conclusion. As a result of the conducted research it is established that application of electromagnetic oscillation of millimetric range for patients with chipped and cut wounds of a breast prevents development of changes of rheological properties of blood, at the same time patients well transfer this procedure that is shown by lack of side effects.</p>","PeriodicalId":19857,"journal":{"name":"Patologicheskaia fiziologiia i eksperimental'naia terapiia","volume":"61 2","pages":"72-5"},"PeriodicalIF":0.0000,"publicationDate":"2017-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"[Possibilities of correction rheological blood svoytv at chipped and cut wounds of the breast ].\",\"authors\":\"V V Masljakov,&nbsp;O A Suhanova,&nbsp;V G Barsukov,&nbsp;K G Kurkin,&nbsp;S A Suhanov\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The purpose: research objective: to study influence of electromagnetic oscillations of millimetric range on rheological properties of blood at patients with chipped and cut wounds of a breast for the purpose of their correction. Methods. For the solution of a research objective we have carried out studying of changes of rheological properties of blood at the 22nd patient with the getting chipped and cut wounds of a breast without internal injury during the next postoperative period. All patient has executed primary surgical processing and drainage of a pleural cavity. At all patients the volume of blood loss has made 200-500 ml. Criteria of inclusion were: existence of the getting wound of a thorax, existence of a small gemotoraks. Criteria of an exception: blood loss existence more than 500 ml, existence of the combined and multiple damages. The main group is divided into two subgroups, in the first 12 patients with application of electromagnetic oscillations of millimetric range, have entered the second 10 people without application of electromagnetic oscillations of millimetric range. The group of comparison was made by 15 rather healthy donor volunteers of the same age and a floor. To all patients the hemotransfusion wasn’t carried out, the volume of infusional therapy was comparable in both groups. Changes of a rheology of blood came to light by means of the accounting of viscosity of blood, change of an index of deformation and aggregation of erythrocytes. Conclusion. As a result of the conducted research it is established that application of electromagnetic oscillation of millimetric range for patients with chipped and cut wounds of a breast prevents development of changes of rheological properties of blood, at the same time patients well transfer this procedure that is shown by lack of side effects.</p>\",\"PeriodicalId\":19857,\"journal\":{\"name\":\"Patologicheskaia fiziologiia i eksperimental'naia terapiia\",\"volume\":\"61 2\",\"pages\":\"72-5\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2017-04-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Patologicheskaia fiziologiia i eksperimental'naia terapiia\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Patologicheskaia fiziologiia i eksperimental'naia terapiia","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

目的:研究目的:研究毫米范围的电磁振荡对乳房碎裂、割伤患者血液流变学特性的影响,以便对其进行矫正。方法。为了解决一个研究目的,我们对第22例无内伤的乳房碎裂创面患者在术后下一阶段血液流变学特性的变化进行了研究。所有患者均进行了初步手术处理和胸膜腔引流。所有患者失血量均为200- 500ml。纳入标准为:存在胸腔创面,存在小肿块。例外标准:存在失血超过500毫升,存在合并和多重损伤。主要分组分为两个亚组,在前12名应用毫米范围电磁振荡的患者中,已进入第二组10名不应用毫米范围电磁振荡的患者。比较组由15名年龄相同、同一楼层的相当健康的志愿者组成。对于所有未输血的患者,两组的输注量相当。血液流变学的变化是通过计算血液粘度、红细胞变形和聚集指数的变化来揭示的。结论。研究结果表明,应用毫米范围的电磁振荡治疗乳房碎裂和割伤,可以防止血液流变学特性的变化,同时患者可以很好地转移这一过程,并且没有副作用。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
[Possibilities of correction rheological blood svoytv at chipped and cut wounds of the breast ].

The purpose: research objective: to study influence of electromagnetic oscillations of millimetric range on rheological properties of blood at patients with chipped and cut wounds of a breast for the purpose of their correction. Methods. For the solution of a research objective we have carried out studying of changes of rheological properties of blood at the 22nd patient with the getting chipped and cut wounds of a breast without internal injury during the next postoperative period. All patient has executed primary surgical processing and drainage of a pleural cavity. At all patients the volume of blood loss has made 200-500 ml. Criteria of inclusion were: existence of the getting wound of a thorax, existence of a small gemotoraks. Criteria of an exception: blood loss existence more than 500 ml, existence of the combined and multiple damages. The main group is divided into two subgroups, in the first 12 patients with application of electromagnetic oscillations of millimetric range, have entered the second 10 people without application of electromagnetic oscillations of millimetric range. The group of comparison was made by 15 rather healthy donor volunteers of the same age and a floor. To all patients the hemotransfusion wasn’t carried out, the volume of infusional therapy was comparable in both groups. Changes of a rheology of blood came to light by means of the accounting of viscosity of blood, change of an index of deformation and aggregation of erythrocytes. Conclusion. As a result of the conducted research it is established that application of electromagnetic oscillation of millimetric range for patients with chipped and cut wounds of a breast prevents development of changes of rheological properties of blood, at the same time patients well transfer this procedure that is shown by lack of side effects.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
[Study of migration and distribution of bone marrow cells transplanted animals with B16 melanoma ]. [Reprogrammed M1 macrophages with inhibited STAT3, STAT6 and/or SMAD3 extends lifespan of mice with experimental carcinoma]. [Activation of regeneration of red and white pulp of the spleen after the combined transplantation of HSC and MSCS in terms of exposure to ionizing radiation]. [Effect of conditioned medium from mesenchymal stem cells on regeneration of endothelium at HCl-induced damage trachea in rats]. [Matrix metalloproteinase-1, -8, -9 and the risk of cardiovascular complications in patients with CHD before and after myocardial revascularization].
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1