圆锥角膜隐形眼镜-现行做法。

IF 0.4 Q4 OPHTHALMOLOGY Open Ophthalmology Journal Pub Date : 2017-07-31 eCollection Date: 2017-01-01 DOI:10.2174/1874364101711010241
Marilita M Moschos, Eirini Nitoda, Panagiotis Georgoudis, Miltos Balidis, Eleftherios Karageorgiadis, Nikos Kozeis
{"title":"圆锥角膜隐形眼镜-现行做法。","authors":"Marilita M Moschos,&nbsp;Eirini Nitoda,&nbsp;Panagiotis Georgoudis,&nbsp;Miltos Balidis,&nbsp;Eleftherios Karageorgiadis,&nbsp;Nikos Kozeis","doi":"10.2174/1874364101711010241","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Keratoconus is a chronic, bilateral, usuallly asymmetrical, non-inflammatory, ectatic disorder, being characterized by progressive steepening, thinning and apical scarring of the cornea. Initially, the patient is asymptomatic, but the visual acuity gradually decreases, resulting in significant vision loss due to the development of irregular astigmatism, myopia, corneal thinning and scarring. The classic treatment of visual rehabilitation in keratoconus is based on spectacles and contact lenses (CLs).</p><p><strong>Objective: </strong>To summarize the types of CLs used in the treatment of keratoconus. This is literature review of several important published articles focusing on the visual rehabilitation in keratoconus with CLs.</p><p><strong>Method: </strong>Gas permeable (GP) CLs have been found to achieve better best corrected visual acuity than spectacles, eliminating 3rd-order coma root-mean-square (RMS) error, 3rd-order RMS, and higher-order RMS. However, they have implicated in reduction of corneal basal epithelial cell and anterior stromal keratocyte densities. Soft CLs seem to provide greater comfort and lower cost, but the low oxygen permeability (if the lens is not a silicone hydrogel), and the inability to mask moderate to severe irregular astigmatism are the main disadvantages of them. On the other hand, scleral CLs ensure stable platforms, which eliminate high-order aberrations and provide good centration and visual acuity. Their main disadvantages include the difficulties in application and removal of these lenses along with corneal flattening and swelling.</p><p><strong>Result: </strong>The modern hybrid CLs are indicated in cases of poor centration, poor stability or intolerance with GP lenses. Finally, piggyback CL systems effectively ameliorate visual acuity, but they have been related to corneal neovascularization and giant papillary conjunctivitis.</p><p><strong>Conclusion: </strong>CLs seem to rehabilitate visual performance, diminishing the power of the cylinder and the high-order aberrations. The final choice of CLs is based on their special features, the subsequent corneal changes and the patient's needs.</p>","PeriodicalId":46347,"journal":{"name":"Open Ophthalmology Journal","volume":null,"pages":null},"PeriodicalIF":0.4000,"publicationDate":"2017-07-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.2174/1874364101711010241","citationCount":"19","resultStr":"{\"title\":\"Contact Lenses for Keratoconus- Current Practice.\",\"authors\":\"Marilita M Moschos,&nbsp;Eirini Nitoda,&nbsp;Panagiotis Georgoudis,&nbsp;Miltos Balidis,&nbsp;Eleftherios Karageorgiadis,&nbsp;Nikos Kozeis\",\"doi\":\"10.2174/1874364101711010241\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Keratoconus is a chronic, bilateral, usuallly asymmetrical, non-inflammatory, ectatic disorder, being characterized by progressive steepening, thinning and apical scarring of the cornea. Initially, the patient is asymptomatic, but the visual acuity gradually decreases, resulting in significant vision loss due to the development of irregular astigmatism, myopia, corneal thinning and scarring. The classic treatment of visual rehabilitation in keratoconus is based on spectacles and contact lenses (CLs).</p><p><strong>Objective: </strong>To summarize the types of CLs used in the treatment of keratoconus. This is literature review of several important published articles focusing on the visual rehabilitation in keratoconus with CLs.</p><p><strong>Method: </strong>Gas permeable (GP) CLs have been found to achieve better best corrected visual acuity than spectacles, eliminating 3rd-order coma root-mean-square (RMS) error, 3rd-order RMS, and higher-order RMS. However, they have implicated in reduction of corneal basal epithelial cell and anterior stromal keratocyte densities. Soft CLs seem to provide greater comfort and lower cost, but the low oxygen permeability (if the lens is not a silicone hydrogel), and the inability to mask moderate to severe irregular astigmatism are the main disadvantages of them. On the other hand, scleral CLs ensure stable platforms, which eliminate high-order aberrations and provide good centration and visual acuity. Their main disadvantages include the difficulties in application and removal of these lenses along with corneal flattening and swelling.</p><p><strong>Result: </strong>The modern hybrid CLs are indicated in cases of poor centration, poor stability or intolerance with GP lenses. Finally, piggyback CL systems effectively ameliorate visual acuity, but they have been related to corneal neovascularization and giant papillary conjunctivitis.</p><p><strong>Conclusion: </strong>CLs seem to rehabilitate visual performance, diminishing the power of the cylinder and the high-order aberrations. The final choice of CLs is based on their special features, the subsequent corneal changes and the patient's needs.</p>\",\"PeriodicalId\":46347,\"journal\":{\"name\":\"Open Ophthalmology Journal\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.4000,\"publicationDate\":\"2017-07-31\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.2174/1874364101711010241\",\"citationCount\":\"19\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Open Ophthalmology Journal\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.2174/1874364101711010241\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2017/1/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"Q4\",\"JCRName\":\"OPHTHALMOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Open Ophthalmology Journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2174/1874364101711010241","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2017/1/1 0:00:00","PubModel":"eCollection","JCR":"Q4","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 19

摘要

背景:圆锥角膜是一种慢性、双侧、通常不对称、非炎性、扩张性疾病,其特征是角膜逐渐变陡、变薄和顶端瘢痕。患者最初无症状,但视力逐渐下降,出现不规则散光、近视、角膜变薄、瘢痕形成,导致视力明显丧失。圆锥角膜视力康复的经典治疗是基于眼镜和隐形眼镜。目的:总结圆锥角膜治疗CLs的类型。本文对已发表的几篇关于圆锥角膜CLs视力康复的重要文章进行了综述。方法:透气性(GP) CLs比眼镜获得更好的最佳矫正视力,消除了三阶昏迷均方根误差(RMS)、三阶RMS和高阶RMS。然而,它们涉及角膜基底上皮细胞和前基质角质细胞密度的减少。软CLs似乎提供更大的舒适性和更低的成本,但低透氧性(如果镜片不是硅水凝胶),无法掩盖中度到严重的不规则散光是它们的主要缺点。另一方面,巩膜CLs确保稳定的平台,消除高阶像差,提供良好的集中和视力。它们的主要缺点包括难以应用和移除这些晶状体以及角膜变平和肿胀。结果:现代混合CLs适用于聚光性差、稳定性差或不耐受的GP镜片。最后,背驮式CL系统可以有效地改善视力,但它们与角膜新生血管和巨大乳头状结膜炎有关。结论:CLs似乎可以恢复视力,减少了视柱的力量和高阶像差。最终选择的CLs是根据其特殊的特点,随后的角膜变化和患者的需要。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Contact Lenses for Keratoconus- Current Practice.

Background: Keratoconus is a chronic, bilateral, usuallly asymmetrical, non-inflammatory, ectatic disorder, being characterized by progressive steepening, thinning and apical scarring of the cornea. Initially, the patient is asymptomatic, but the visual acuity gradually decreases, resulting in significant vision loss due to the development of irregular astigmatism, myopia, corneal thinning and scarring. The classic treatment of visual rehabilitation in keratoconus is based on spectacles and contact lenses (CLs).

Objective: To summarize the types of CLs used in the treatment of keratoconus. This is literature review of several important published articles focusing on the visual rehabilitation in keratoconus with CLs.

Method: Gas permeable (GP) CLs have been found to achieve better best corrected visual acuity than spectacles, eliminating 3rd-order coma root-mean-square (RMS) error, 3rd-order RMS, and higher-order RMS. However, they have implicated in reduction of corneal basal epithelial cell and anterior stromal keratocyte densities. Soft CLs seem to provide greater comfort and lower cost, but the low oxygen permeability (if the lens is not a silicone hydrogel), and the inability to mask moderate to severe irregular astigmatism are the main disadvantages of them. On the other hand, scleral CLs ensure stable platforms, which eliminate high-order aberrations and provide good centration and visual acuity. Their main disadvantages include the difficulties in application and removal of these lenses along with corneal flattening and swelling.

Result: The modern hybrid CLs are indicated in cases of poor centration, poor stability or intolerance with GP lenses. Finally, piggyback CL systems effectively ameliorate visual acuity, but they have been related to corneal neovascularization and giant papillary conjunctivitis.

Conclusion: CLs seem to rehabilitate visual performance, diminishing the power of the cylinder and the high-order aberrations. The final choice of CLs is based on their special features, the subsequent corneal changes and the patient's needs.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
0.50
自引率
0.00%
发文量
24
期刊介绍: The Open Ophthalmology Journal is an Open Access online journal, which publishes research articles, reviews/mini-reviews, letters and guest edited single topic issues in all important areas of experimental and clinical research in ophthalmology, including use of ophthalmological therapies, devices and surgical techniques. The Open Ophthalmology Journal, a peer-reviewed journal, is an important and reliable source of current information on developments in the field. The emphasis will be on publishing quality papers rapidly and making them freely available to researchers worldwide.
期刊最新文献
A Narrative Review of Morquio Syndrome: Mucopolysaccharidosis (MPS) Type IV MGrx - A Novel Multi-modal Thermal Device for Treating Moderate to Severe Meibomian Gland Dysfunction and Dry Eye Determinants of Refractive Errors on School-going Children Attending Ophthalmic Clinic of AlMoosa Hospital in Saudi Arabia A Systematic Review and Meta-analysis of Convergence Insufficiency Prevalence and Management Options Photodynamic and Anti-VEGF Therapy for Polypoidal Choroidal Vasculopathy - ‘Real World’ Outcomes in a Caucasian Population
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1