一种新型采血装置采集的指尖微量血样与传统静脉血测定的血液检测结果的相关性:一篇英文二级出版物。

IF 1.1 Q4 MEDICINE, RESEARCH & EXPERIMENTAL KEIO JOURNAL OF MEDICINE Pub Date : 2018-06-25 Epub Date: 2017-11-21 DOI:10.2302/kjm.2017-0009-OA
Hajime Iwasawa, Tomoaki Nishimura, Shota Nemoto, Naoki Aikawa, Kiyoaki Watanabe
{"title":"一种新型采血装置采集的指尖微量血样与传统静脉血测定的血液检测结果的相关性:一篇英文二级出版物。","authors":"Hajime Iwasawa,&nbsp;Tomoaki Nishimura,&nbsp;Shota Nemoto,&nbsp;Naoki Aikawa,&nbsp;Kiyoaki Watanabe","doi":"10.2302/kjm.2017-0009-OA","DOIUrl":null,"url":null,"abstract":"<p><p>In this study, we investigated the correlations between biochemical and hematological test results obtained using microliter-scale fingertip blood samples collected with a newly developed blood collection device and those obtained using conventional venous blood. Eighty volunteer subjects were enrolled in this study. Blood samples were drawn from the fingertip of the ring finger by a single puncture, and 60-µL samples were promptly and accurately aspirated into a blood collection chip. Then the chip was tightly sealed in a chip container and was shaken to mix the contents without dispersion. For biochemical tests other than that for HbA1c, blood was collected without anticoagulant and centrifuged to obtain 15 µL of serum which was then diluted with 190 µL of physiological saline for the assay. For hematological tests and the test for HbA1c, the sample was assayed with blood collected using EDTA-2 K. Good correlations were obtained between the test results of the assay using fingertip blood and that using venous blood. The correlation coefficients were ≥0.97 for TG, T-CHO, HDL-C, LDL-C, GLU, ALT, γ-GTP, UA, BUN, and HbA1c and ≥0.95 for WBC, RBC, Hgb, and Hct. These results suggest that our microliter-scale blood testing system is comparable to assays using venous blood and may be useful as a rapid and simple test to determine basic clinical parameters that are close to the reference intervals.</p>","PeriodicalId":46245,"journal":{"name":"KEIO JOURNAL OF MEDICINE","volume":null,"pages":null},"PeriodicalIF":1.1000,"publicationDate":"2018-06-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.2302/kjm.2017-0009-OA","citationCount":"1","resultStr":"{\"title\":\"Correlation of the Blood Test Results Obtained between Assays Using Microliter-scale Fingertip Blood Samples Collected with a Novel Blood Collection Device and Conventional Venous Blood Assays: a Secondary Publication in English.\",\"authors\":\"Hajime Iwasawa,&nbsp;Tomoaki Nishimura,&nbsp;Shota Nemoto,&nbsp;Naoki Aikawa,&nbsp;Kiyoaki Watanabe\",\"doi\":\"10.2302/kjm.2017-0009-OA\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>In this study, we investigated the correlations between biochemical and hematological test results obtained using microliter-scale fingertip blood samples collected with a newly developed blood collection device and those obtained using conventional venous blood. Eighty volunteer subjects were enrolled in this study. Blood samples were drawn from the fingertip of the ring finger by a single puncture, and 60-µL samples were promptly and accurately aspirated into a blood collection chip. Then the chip was tightly sealed in a chip container and was shaken to mix the contents without dispersion. For biochemical tests other than that for HbA1c, blood was collected without anticoagulant and centrifuged to obtain 15 µL of serum which was then diluted with 190 µL of physiological saline for the assay. For hematological tests and the test for HbA1c, the sample was assayed with blood collected using EDTA-2 K. Good correlations were obtained between the test results of the assay using fingertip blood and that using venous blood. The correlation coefficients were ≥0.97 for TG, T-CHO, HDL-C, LDL-C, GLU, ALT, γ-GTP, UA, BUN, and HbA1c and ≥0.95 for WBC, RBC, Hgb, and Hct. These results suggest that our microliter-scale blood testing system is comparable to assays using venous blood and may be useful as a rapid and simple test to determine basic clinical parameters that are close to the reference intervals.</p>\",\"PeriodicalId\":46245,\"journal\":{\"name\":\"KEIO JOURNAL OF MEDICINE\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.1000,\"publicationDate\":\"2018-06-25\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.2302/kjm.2017-0009-OA\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"KEIO JOURNAL OF MEDICINE\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.2302/kjm.2017-0009-OA\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2017/11/21 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q4\",\"JCRName\":\"MEDICINE, RESEARCH & EXPERIMENTAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"KEIO JOURNAL OF MEDICINE","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2302/kjm.2017-0009-OA","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2017/11/21 0:00:00","PubModel":"Epub","JCR":"Q4","JCRName":"MEDICINE, RESEARCH & EXPERIMENTAL","Score":null,"Total":0}
引用次数: 1

摘要

在这项研究中,我们研究了用新研制的采血装置采集的微升指尖血样和传统静脉血采集的生化和血液学检测结果的相关性。80名志愿者参加了这项研究。通过单次穿刺从无名指指尖抽取血液样本,并及时准确地将60µL样本吸入采血芯片中。然后将芯片紧紧密封在芯片容器中,摇晃以混合内容物而不分散。除HbA1c外的其他生化试验,取不含抗凝血剂的血液,离心得到15µL血清,用生理盐水190µL稀释后进行检测。对于血液学测试和HbA1c测试,样品用EDTA-2 K采集的血液进行检测。指尖血检测结果与静脉血检测结果具有良好的相关性。TG、T-CHO、HDL-C、LDL-C、GLU、ALT、γ-GTP、UA、BUN和HbA1c的相关系数≥0.97,WBC、RBC、Hgb和Hct的相关系数≥0.95。这些结果表明,我们的微升尺度血液检测系统可与静脉血检测相媲美,可作为一种快速、简单的检测方法,用于确定接近参考区间的基本临床参数。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Correlation of the Blood Test Results Obtained between Assays Using Microliter-scale Fingertip Blood Samples Collected with a Novel Blood Collection Device and Conventional Venous Blood Assays: a Secondary Publication in English.

In this study, we investigated the correlations between biochemical and hematological test results obtained using microliter-scale fingertip blood samples collected with a newly developed blood collection device and those obtained using conventional venous blood. Eighty volunteer subjects were enrolled in this study. Blood samples were drawn from the fingertip of the ring finger by a single puncture, and 60-µL samples were promptly and accurately aspirated into a blood collection chip. Then the chip was tightly sealed in a chip container and was shaken to mix the contents without dispersion. For biochemical tests other than that for HbA1c, blood was collected without anticoagulant and centrifuged to obtain 15 µL of serum which was then diluted with 190 µL of physiological saline for the assay. For hematological tests and the test for HbA1c, the sample was assayed with blood collected using EDTA-2 K. Good correlations were obtained between the test results of the assay using fingertip blood and that using venous blood. The correlation coefficients were ≥0.97 for TG, T-CHO, HDL-C, LDL-C, GLU, ALT, γ-GTP, UA, BUN, and HbA1c and ≥0.95 for WBC, RBC, Hgb, and Hct. These results suggest that our microliter-scale blood testing system is comparable to assays using venous blood and may be useful as a rapid and simple test to determine basic clinical parameters that are close to the reference intervals.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
KEIO JOURNAL OF MEDICINE
KEIO JOURNAL OF MEDICINE MEDICINE, RESEARCH & EXPERIMENTAL-
CiteScore
3.10
自引率
0.00%
发文量
23
期刊最新文献
Intravenous Regeneration-associated Cell Transplantation Enhances Tissue Recovery in Mice with Acute Ischemic Stroke. Warfarin Therapy and Percutaneous Left Atrial Appendage Closure for a Patient with Atrial Fibrillation and Antithrombin-III Deficiency. Efficacy of Cognitive Stimulation Therapy for Cognition in Patients with Vascular Cognitive Impairment: A Pilot Randomized Controlled Trial. Robotic Lobectomy with a Single Robotic Stapler from One 12-mm Port: A Multi-institutional Study. Incidence of Radiation-induced Nausea and Vomiting: A Prospective Single-institution Pilot Study.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1