维生素D检测。

2区 医学 Q2 Medicine Frontiers of Hormone Research Pub Date : 2018-01-01 Epub Date: 2018-03-29 DOI:10.1159/000486062
Daniel D Bikle
{"title":"维生素D检测。","authors":"Daniel D Bikle","doi":"10.1159/000486062","DOIUrl":null,"url":null,"abstract":"<p><p>The number of requests for vitamin D metabolite measurements has increased dramatically over the past decade leading commercial laboratories to develop rapid high throughput assays. The measurement of 25-hydroxyvitamin D (25[OH]D) and to a lesser extent 1,25-dihydroxyvitamin D (1,25[OH]2D) dominates these requests, but requests for multiple metabolite measurements in the same sample are also increasing. The most commonly used methods include immunoassays and liquid chromatography/mass spectrometry (LC-MS). Each method has its advantages and disadvantages, but with improvements in technology, especially in LC-MS, this method is gaining ascendance due to its greater precision and flexibility. The use of standards from the National Institutes of Standards and Technology has substantially reduced the variability from laboratory to laboratory, thereby improving the reliability of these measurements. Although the current demand is for measurement of total vitamin D metabolite levels, these metabolites circulate in blood tightly bound to vitamin D binding protein (DBP) and albumin with less than 1% free. The free concentration may be a more accurate indicator of vitamin D status especially in individuals with DBP levels that deviate from the normal population. Thus, methods to measure the free concentration at least of 25(OH)D are becoming available and may supplement if not replace measurements of total levels.</p>","PeriodicalId":50428,"journal":{"name":"Frontiers of Hormone Research","volume":"50 ","pages":"14-30"},"PeriodicalIF":0.0000,"publicationDate":"2018-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1159/000486062","citationCount":"15","resultStr":"{\"title\":\"Vitamin D Assays.\",\"authors\":\"Daniel D Bikle\",\"doi\":\"10.1159/000486062\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The number of requests for vitamin D metabolite measurements has increased dramatically over the past decade leading commercial laboratories to develop rapid high throughput assays. The measurement of 25-hydroxyvitamin D (25[OH]D) and to a lesser extent 1,25-dihydroxyvitamin D (1,25[OH]2D) dominates these requests, but requests for multiple metabolite measurements in the same sample are also increasing. The most commonly used methods include immunoassays and liquid chromatography/mass spectrometry (LC-MS). Each method has its advantages and disadvantages, but with improvements in technology, especially in LC-MS, this method is gaining ascendance due to its greater precision and flexibility. The use of standards from the National Institutes of Standards and Technology has substantially reduced the variability from laboratory to laboratory, thereby improving the reliability of these measurements. Although the current demand is for measurement of total vitamin D metabolite levels, these metabolites circulate in blood tightly bound to vitamin D binding protein (DBP) and albumin with less than 1% free. The free concentration may be a more accurate indicator of vitamin D status especially in individuals with DBP levels that deviate from the normal population. Thus, methods to measure the free concentration at least of 25(OH)D are becoming available and may supplement if not replace measurements of total levels.</p>\",\"PeriodicalId\":50428,\"journal\":{\"name\":\"Frontiers of Hormone Research\",\"volume\":\"50 \",\"pages\":\"14-30\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1159/000486062\",\"citationCount\":\"15\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Frontiers of Hormone Research\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1159/000486062\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2018/3/29 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q2\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Frontiers of Hormone Research","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1159/000486062","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2018/3/29 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 15

摘要

在过去十年中,对维生素D代谢物测量的要求数量急剧增加,导致商业实验室开发快速高通量分析。测量25-羟基维生素D (25[OH]D)和较小程度的1,25-二羟基维生素D (1,25[OH]2D)在这些要求中占主导地位,但在同一样品中测量多种代谢物的要求也在增加。最常用的方法包括免疫分析和液相色谱/质谱分析(LC-MS)。每种方法都有其优点和缺点,但随着技术的进步,特别是在LC-MS中,这种方法由于其更高的精度和灵活性而获得优势。使用美国国家标准与技术研究院的标准大大减少了实验室之间的差异,从而提高了这些测量的可靠性。虽然目前的需求是测量总维生素D代谢物水平,但这些代谢物在血液中与维生素D结合蛋白(DBP)和白蛋白紧密结合,游离量不到1%。游离浓度可能是维生素D状态的一个更准确的指标,特别是在DBP水平偏离正常人群的个体中。因此,测量至少25(OH)D游离浓度的方法正在变得可行,即使不能替代总水平的测量,也可以作为补充。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Vitamin D Assays.

The number of requests for vitamin D metabolite measurements has increased dramatically over the past decade leading commercial laboratories to develop rapid high throughput assays. The measurement of 25-hydroxyvitamin D (25[OH]D) and to a lesser extent 1,25-dihydroxyvitamin D (1,25[OH]2D) dominates these requests, but requests for multiple metabolite measurements in the same sample are also increasing. The most commonly used methods include immunoassays and liquid chromatography/mass spectrometry (LC-MS). Each method has its advantages and disadvantages, but with improvements in technology, especially in LC-MS, this method is gaining ascendance due to its greater precision and flexibility. The use of standards from the National Institutes of Standards and Technology has substantially reduced the variability from laboratory to laboratory, thereby improving the reliability of these measurements. Although the current demand is for measurement of total vitamin D metabolite levels, these metabolites circulate in blood tightly bound to vitamin D binding protein (DBP) and albumin with less than 1% free. The free concentration may be a more accurate indicator of vitamin D status especially in individuals with DBP levels that deviate from the normal population. Thus, methods to measure the free concentration at least of 25(OH)D are becoming available and may supplement if not replace measurements of total levels.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Frontiers of Hormone Research
Frontiers of Hormone Research 医学-内分泌学与代谢
自引率
0.00%
发文量
0
期刊介绍: A series of integrated overviews on cutting-edge topics New sophisticated technologies and methodological approaches in diagnostics and therapeutics have led to significant improvements in identifying and characterizing an increasing number of medical conditions, which is particularly true for all aspects of endocrine and metabolic dysfunctions. Novel insights in endocrine physiology and pathophysiology allow for new perspectives in clinical management and thus lead to the development of molecular, personalized treatments. In view of this, the active interplay between basic scientists and clinicians has become fundamental, both to provide patients with the most appropriate care and to advance future research.
期刊最新文献
Endocrine and Metabolic Late Effects in Cancer Survivors Cardiometabolic Risk, Part 1: Chemotherapy and Radiotherapy - Old Foes Still Threatening Cancer Survivors? Hypothalamic-Pituitary Dysfunctions Other Than Growth Hormone Deficiency in Cancer Survivors. Diabetes in Cancer Patients: Risks, Goals and Management. Thyroid Dysfunction and Thyroid Cancer in Childhood Cancer Survivors: Prevalence, Surveillance and Management.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1