{"title":"IG-锉在牙髓学中测量根尖直径的体外研究。","authors":"Massimo Amato,&nbsp;Alfredo Iandolo,&nbsp;Giuseppe Pantaleo,&nbsp;Dina Abtellatif,&nbsp;Michele Simeone,&nbsp;Angelo Lizio,&nbsp;Roberto Lo Giudice,&nbsp;Giuseppe Lo Giudice","doi":"10.2174/1745017901814010638","DOIUrl":null,"url":null,"abstract":"<p><strong>Aim: </strong>The aim of this study was to evaluate the efficacy of the IG-file, a new instrument designed for apical diameter gauging.</p><p><strong>Materials and methods: </strong>After shaping with F1 Universal Protaper, 60 roots were randomly divided into two groups and assigned to two operators, One Expert in Endodontics (EO) and One Unexpert (UO).In each sample, after canal curvatures have been detected, the apical diameters were measured with the IG-file and the K-NiTi. The results were compared with the reference value obtained by retrograde apical gauging. The data were statistically analyzed.</p><p><strong>Results: </strong>Among 60 samples, 10% of errors were recorded when the IG-files were used; in the K-NiTi group the incorrect measurements were 70%.In both groups (expert and unexpert) the IG-file measurements were more accurate than the K-NiTi (90 <i>vs</i> 33 and 90 <i>vs</i> 26,7). The differences were statistically significant.In curved canals, the difference between measurement rates performed with both instruments was statistically significant (85,7% IG-file <i>vs</i> 28,6% K-NiTi) as well as for the samples without curvatures (92,3% IG file <i>vs</i> 30,8% NiTi file).In root canals without curvatures overestimation errors in K-NiTi file group are more frequent than underestimation errors. This difference was statistically significant.</p><p><strong>Conclusion: </strong>A proper gauging of the apical diameter has a key role in endodontic therapy; an incorrect measurement can lead to clinical failures. This \"<i>in vitro</i>\" study highlights that IG-file improves measurement accuracy independently from clinician experience. Furthermore, in curved canals, the IG-file is more accurate than K-NiTi.</p>","PeriodicalId":47284,"journal":{"name":"Open Dentistry Journal","volume":"12 ","pages":"638-646"},"PeriodicalIF":0.5000,"publicationDate":"2018-09-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.2174/1745017901814010638","citationCount":"3","resultStr":"{\"title\":\"The IG- file use to Gauge the Apical Diameter in Endodontics: An <i>In Vitro</i> Study.\",\"authors\":\"Massimo Amato,&nbsp;Alfredo Iandolo,&nbsp;Giuseppe Pantaleo,&nbsp;Dina Abtellatif,&nbsp;Michele Simeone,&nbsp;Angelo Lizio,&nbsp;Roberto Lo Giudice,&nbsp;Giuseppe Lo Giudice\",\"doi\":\"10.2174/1745017901814010638\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Aim: </strong>The aim of this study was to evaluate the efficacy of the IG-file, a new instrument designed for apical diameter gauging.</p><p><strong>Materials and methods: </strong>After shaping with F1 Universal Protaper, 60 roots were randomly divided into two groups and assigned to two operators, One Expert in Endodontics (EO) and One Unexpert (UO).In each sample, after canal curvatures have been detected, the apical diameters were measured with the IG-file and the K-NiTi. The results were compared with the reference value obtained by retrograde apical gauging. The data were statistically analyzed.</p><p><strong>Results: </strong>Among 60 samples, 10% of errors were recorded when the IG-files were used; in the K-NiTi group the incorrect measurements were 70%.In both groups (expert and unexpert) the IG-file measurements were more accurate than the K-NiTi (90 <i>vs</i> 33 and 90 <i>vs</i> 26,7). The differences were statistically significant.In curved canals, the difference between measurement rates performed with both instruments was statistically significant (85,7% IG-file <i>vs</i> 28,6% K-NiTi) as well as for the samples without curvatures (92,3% IG file <i>vs</i> 30,8% NiTi file).In root canals without curvatures overestimation errors in K-NiTi file group are more frequent than underestimation errors. This difference was statistically significant.</p><p><strong>Conclusion: </strong>A proper gauging of the apical diameter has a key role in endodontic therapy; an incorrect measurement can lead to clinical failures. This \\\"<i>in vitro</i>\\\" study highlights that IG-file improves measurement accuracy independently from clinician experience. Furthermore, in curved canals, the IG-file is more accurate than K-NiTi.</p>\",\"PeriodicalId\":47284,\"journal\":{\"name\":\"Open Dentistry Journal\",\"volume\":\"12 \",\"pages\":\"638-646\"},\"PeriodicalIF\":0.5000,\"publicationDate\":\"2018-09-28\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.2174/1745017901814010638\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Open Dentistry Journal\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.2174/1745017901814010638\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2018/1/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"Q4\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Open Dentistry Journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2174/1745017901814010638","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2018/1/1 0:00:00","PubModel":"eCollection","JCR":"Q4","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 3

摘要

目的:评价一种新型根尖直径测量仪ig -锉的测量效果。材料和方法:使用F1万能Protaper塑形后,将60根根随机分为两组,分别分配给两名操作人员,一名专家(EO)和一名非专家(UO)。在每个样本中,检测根管曲率后,用ig锉和K-NiTi测量根尖直径。结果与逆行根尖测量的参考值进行了比较。对数据进行统计学分析。结果:60份样本中,使用IG-files时记录的误差为10%;在K-NiTi组中,不正确的测量值为70%。在两组(专家和非专家)中,ig文件测量比K-NiTi更准确(90 vs 33和90 vs 26,7)。差异有统计学意义。在弯曲的管道中,两种仪器的测量率差异具有统计学意义(85,7% IG锉vs 28.6% K-NiTi),以及对于没有弯曲的样本(92,3% IG锉vs 30.8% NiTi锉)。在无弯曲根管中,K-NiTi锉组的高估误差比低估误差更常见。这一差异具有统计学意义。结论:正确测量根管根尖直径在根管治疗中起着关键作用;不正确的测量可能导致临床失败。这项“体外”研究强调,ig文件提高测量精度独立于临床医生的经验。此外,在弯曲的管道中,ig锉比K-NiTi更精确。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
The IG- file use to Gauge the Apical Diameter in Endodontics: An In Vitro Study.

Aim: The aim of this study was to evaluate the efficacy of the IG-file, a new instrument designed for apical diameter gauging.

Materials and methods: After shaping with F1 Universal Protaper, 60 roots were randomly divided into two groups and assigned to two operators, One Expert in Endodontics (EO) and One Unexpert (UO).In each sample, after canal curvatures have been detected, the apical diameters were measured with the IG-file and the K-NiTi. The results were compared with the reference value obtained by retrograde apical gauging. The data were statistically analyzed.

Results: Among 60 samples, 10% of errors were recorded when the IG-files were used; in the K-NiTi group the incorrect measurements were 70%.In both groups (expert and unexpert) the IG-file measurements were more accurate than the K-NiTi (90 vs 33 and 90 vs 26,7). The differences were statistically significant.In curved canals, the difference between measurement rates performed with both instruments was statistically significant (85,7% IG-file vs 28,6% K-NiTi) as well as for the samples without curvatures (92,3% IG file vs 30,8% NiTi file).In root canals without curvatures overestimation errors in K-NiTi file group are more frequent than underestimation errors. This difference was statistically significant.

Conclusion: A proper gauging of the apical diameter has a key role in endodontic therapy; an incorrect measurement can lead to clinical failures. This "in vitro" study highlights that IG-file improves measurement accuracy independently from clinician experience. Furthermore, in curved canals, the IG-file is more accurate than K-NiTi.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Open Dentistry Journal
Open Dentistry Journal DENTISTRY, ORAL SURGERY & MEDICINE-
CiteScore
2.00
自引率
0.00%
发文量
86
期刊最新文献
Caries Experience and Treatment Needs in Urban and Rural Environments in School-Age Children from Three Provinces of Ecuador: A Cross-Sectional Study Cannabidiol in Dentistry: A Scoping Review Effectiveness of 38% Silver Diamine Fluoride in Reducing Dentine Hypersensitivity on Exposed Root Surface in Older Chinese Adults: Study Protocol for a Randomised Double-Blind Study Challenges and Opportunities for Dental Education from COVID-19 An Analysis of Different Techniques Used to Seal Post-Extractive Sites—A Preliminary Report
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1