急性缺血性卒中取栓后,ADAPT与支架回收器引起的亚急性血管损伤的比较:动物模型的组织学和超微结构研究。

Q1 Medicine Interventional Neurology Pub Date : 2018-10-01 Epub Date: 2018-08-31 DOI:10.1159/000491028
Simone Peschillo, Alejandro Tomasello, Francesco Diana, David Hernandez, Giada Toccaceli, Marta Rosal-Fontana, Marielle Esteves Coelho, Paolo Missori
{"title":"急性缺血性卒中取栓后,ADAPT与支架回收器引起的亚急性血管损伤的比较:动物模型的组织学和超微结构研究。","authors":"Simone Peschillo,&nbsp;Alejandro Tomasello,&nbsp;Francesco Diana,&nbsp;David Hernandez,&nbsp;Giada Toccaceli,&nbsp;Marta Rosal-Fontana,&nbsp;Marielle Esteves Coelho,&nbsp;Paolo Missori","doi":"10.1159/000491028","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>To assess the delayed (15 days) histological and ultrastructural changes occurring following endovascular treatment with a direct aspiration first pass technique (ADAPT) or stent retrievers (SRs) and to compare the findings in order to determine which is the least harmful technique and what changes occur.</p><p><strong>Materials and methods: </strong>Damage to the wall of swine extracranial arteries was evaluated after ADAPT with the Penumbra system or thrombectomy with various SRs. The procedures were performed using two pigs as animal models; extracranial cervical arteries were selected based on their diameters in order to reproduce the procedures as in human intracranial arteries, and endovascular thrombectomies were done after the injection of autologous thrombi. Two weeks later, the animals were euthanized, and 60 arterial samples were obtained for analysis by optical and electron microscopy.</p><p><strong>Results: </strong>Optical and electron microscopy revealed that both techniques cause, in different way, alterations to the structure of the vessel wall.</p><p><strong>Conclusions: </strong>Both techniques caused damage to the vessel wall. The main damages were localized at the level of the tunica media and adventitia, instead of the tunica intima as in the acute phase. Further investigation is required to better understand whether these alterations could have chronic consequences.</p>","PeriodicalId":46280,"journal":{"name":"Interventional Neurology","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2018-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1159/000491028","citationCount":"20","resultStr":"{\"title\":\"Comparison of Subacute Vascular Damage Caused by ADAPT versus Stent Retriever Devices after Thrombectomy in Acute Ischemic Stroke: Histological and Ultrastructural Study in an Animal Model.\",\"authors\":\"Simone Peschillo,&nbsp;Alejandro Tomasello,&nbsp;Francesco Diana,&nbsp;David Hernandez,&nbsp;Giada Toccaceli,&nbsp;Marta Rosal-Fontana,&nbsp;Marielle Esteves Coelho,&nbsp;Paolo Missori\",\"doi\":\"10.1159/000491028\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objectives: </strong>To assess the delayed (15 days) histological and ultrastructural changes occurring following endovascular treatment with a direct aspiration first pass technique (ADAPT) or stent retrievers (SRs) and to compare the findings in order to determine which is the least harmful technique and what changes occur.</p><p><strong>Materials and methods: </strong>Damage to the wall of swine extracranial arteries was evaluated after ADAPT with the Penumbra system or thrombectomy with various SRs. The procedures were performed using two pigs as animal models; extracranial cervical arteries were selected based on their diameters in order to reproduce the procedures as in human intracranial arteries, and endovascular thrombectomies were done after the injection of autologous thrombi. Two weeks later, the animals were euthanized, and 60 arterial samples were obtained for analysis by optical and electron microscopy.</p><p><strong>Results: </strong>Optical and electron microscopy revealed that both techniques cause, in different way, alterations to the structure of the vessel wall.</p><p><strong>Conclusions: </strong>Both techniques caused damage to the vessel wall. The main damages were localized at the level of the tunica media and adventitia, instead of the tunica intima as in the acute phase. Further investigation is required to better understand whether these alterations could have chronic consequences.</p>\",\"PeriodicalId\":46280,\"journal\":{\"name\":\"Interventional Neurology\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1159/000491028\",\"citationCount\":\"20\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Interventional Neurology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1159/000491028\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2018/8/31 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q1\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Interventional Neurology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1159/000491028","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2018/8/31 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 20

摘要

目的:评估血管内直接抽吸首次通过技术(ADAPT)或支架回收器(SRs)治疗后发生的延迟(15天)组织学和超微结构变化,并比较结果,以确定哪种技术危害最小以及发生了什么变化。材料和方法:采用半暗带系统或各种SRs取栓后,对猪颅外动脉壁损伤进行评估。实验以2头猪为动物模型;根据颈外动脉的直径选择颈外动脉,以复制人颅内动脉的过程,并在注射自体血栓后进行血管内血栓切除术。两周后,对动物实施安乐死,并获得60个动脉样本进行光学和电子显微镜分析。结果:光学和电子显微镜显示,这两种技术以不同的方式引起血管壁结构的改变。结论:两种方法均对血管壁造成损伤。急性期的损伤主要集中在中膜和外膜水平,而不是在内膜水平。需要进一步的调查来更好地了解这些改变是否会产生慢性后果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Comparison of Subacute Vascular Damage Caused by ADAPT versus Stent Retriever Devices after Thrombectomy in Acute Ischemic Stroke: Histological and Ultrastructural Study in an Animal Model.

Objectives: To assess the delayed (15 days) histological and ultrastructural changes occurring following endovascular treatment with a direct aspiration first pass technique (ADAPT) or stent retrievers (SRs) and to compare the findings in order to determine which is the least harmful technique and what changes occur.

Materials and methods: Damage to the wall of swine extracranial arteries was evaluated after ADAPT with the Penumbra system or thrombectomy with various SRs. The procedures were performed using two pigs as animal models; extracranial cervical arteries were selected based on their diameters in order to reproduce the procedures as in human intracranial arteries, and endovascular thrombectomies were done after the injection of autologous thrombi. Two weeks later, the animals were euthanized, and 60 arterial samples were obtained for analysis by optical and electron microscopy.

Results: Optical and electron microscopy revealed that both techniques cause, in different way, alterations to the structure of the vessel wall.

Conclusions: Both techniques caused damage to the vessel wall. The main damages were localized at the level of the tunica media and adventitia, instead of the tunica intima as in the acute phase. Further investigation is required to better understand whether these alterations could have chronic consequences.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Interventional Neurology
Interventional Neurology CLINICAL NEUROLOGY-
自引率
0.00%
发文量
0
期刊最新文献
Recanalization of Tandem Vertebrobasilar Occlusions with Contralateral Vertebral Occlusion or Hypoplasia via either Direct Passage or the SHERPA Technique. Does the Addition of Non-Approved Inclusion and Exclusion Criteria for rtPA Impact Treatment Rates? Findings in Australia, the UK, and the USA. In vitro Remote Aspiration Embolectomy for the Treatment of Acute Ischemic Stroke. Endovascular Reperfusion for Acute Isolated Cervical Carotid Occlusions: The Concept of "Hemodynamic Thrombectomy". An Appraisal of the 2018 Guidelines for the Early Management of Patients with Acute Ischemic Stroke.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1