建立重组腺病毒5型载体型埃博拉疫苗(Ad5-EBOV)病毒滴度中国国家标准。

Q1 Medicine Human Gene Therapy Clinical Development Pub Date : 2018-12-01 Epub Date: 2018-12-04 DOI:10.1089/humc.2018.129
Yuhua Li, Ling Wang, Tao Zhu, Shipo Wu, Liqiang Feng, Ping Cheng, Jingjing Liu, Junzhi Wang
{"title":"建立重组腺病毒5型载体型埃博拉疫苗(Ad5-EBOV)病毒滴度中国国家标准。","authors":"Yuhua Li,&nbsp;Ling Wang,&nbsp;Tao Zhu,&nbsp;Shipo Wu,&nbsp;Liqiang Feng,&nbsp;Ping Cheng,&nbsp;Jingjing Liu,&nbsp;Junzhi Wang","doi":"10.1089/humc.2018.129","DOIUrl":null,"url":null,"abstract":"<p><p>The 2014 Ebola outbreak in West Africa brought great threat to public health worldwide. There was no approved antiviral therapy or vaccine available to control the disease at that time. Several kinds of Ebola vaccines were urgently under development across the world. Among these, the novel recombinant adenovirus type 5 vector-based Ebola vaccine (Ad5-EBOV)-the first Ebola vaccine based on the 2014 Zaire Guinea epidemic strain-was developed in China, and its safety and immunogenicity were demonstrated in China and Sierra Leone. The license to market the drug was approved on October 19, 2017, by the Chinese Food and Drug Administration. In order to standardize the test on the Ad5-EBOV virus titer, China's national standard substance for the virus titer of Ad5-EBOV was established according to the recommendations for the preparation, characterization, and establishment of international and other biological reference standards from the World Health Organization and Chinese Pharmacopoeia (third edition). The standard for the Ad5-EBOV virus titer was prepared with a volume of 0.5 mL per ampoule in lyophilized form. The samples of the standard, designated as A, B, C, D with different aims, were blinded and distributed to five laboratories to be collaboratively calibrated. The virus titer for this standard was determined with the antibody staining method according to the instructions in the Adeno-X™ Rapid Titer Kit. The homogeneity and stability of the standard substance were also satisfied. The virus titer standard value was 8.54 lg infectious units (IFU)/mL, and the 95% confidence interval was between 7.94 lg IFU/mL and 9.14 lg IFU/mL. This standard was approved by the Chinese national committee and is available on the National Institutes for Food and Drug Control Web site ( www.nifdc.org.cn ; lot no. 250019-201501).</p>","PeriodicalId":51315,"journal":{"name":"Human Gene Therapy Clinical Development","volume":"29 4","pages":"226-232"},"PeriodicalIF":0.0000,"publicationDate":"2018-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1089/humc.2018.129","citationCount":"7","resultStr":"{\"title\":\"Establishing China's National Standard for the Recombinant Adenovirus Type 5 Vector-Based Ebola Vaccine (Ad5-EBOV) Virus Titer.\",\"authors\":\"Yuhua Li,&nbsp;Ling Wang,&nbsp;Tao Zhu,&nbsp;Shipo Wu,&nbsp;Liqiang Feng,&nbsp;Ping Cheng,&nbsp;Jingjing Liu,&nbsp;Junzhi Wang\",\"doi\":\"10.1089/humc.2018.129\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The 2014 Ebola outbreak in West Africa brought great threat to public health worldwide. There was no approved antiviral therapy or vaccine available to control the disease at that time. Several kinds of Ebola vaccines were urgently under development across the world. Among these, the novel recombinant adenovirus type 5 vector-based Ebola vaccine (Ad5-EBOV)-the first Ebola vaccine based on the 2014 Zaire Guinea epidemic strain-was developed in China, and its safety and immunogenicity were demonstrated in China and Sierra Leone. The license to market the drug was approved on October 19, 2017, by the Chinese Food and Drug Administration. In order to standardize the test on the Ad5-EBOV virus titer, China's national standard substance for the virus titer of Ad5-EBOV was established according to the recommendations for the preparation, characterization, and establishment of international and other biological reference standards from the World Health Organization and Chinese Pharmacopoeia (third edition). The standard for the Ad5-EBOV virus titer was prepared with a volume of 0.5 mL per ampoule in lyophilized form. The samples of the standard, designated as A, B, C, D with different aims, were blinded and distributed to five laboratories to be collaboratively calibrated. The virus titer for this standard was determined with the antibody staining method according to the instructions in the Adeno-X™ Rapid Titer Kit. The homogeneity and stability of the standard substance were also satisfied. The virus titer standard value was 8.54 lg infectious units (IFU)/mL, and the 95% confidence interval was between 7.94 lg IFU/mL and 9.14 lg IFU/mL. This standard was approved by the Chinese national committee and is available on the National Institutes for Food and Drug Control Web site ( www.nifdc.org.cn ; lot no. 250019-201501).</p>\",\"PeriodicalId\":51315,\"journal\":{\"name\":\"Human Gene Therapy Clinical Development\",\"volume\":\"29 4\",\"pages\":\"226-232\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1089/humc.2018.129\",\"citationCount\":\"7\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Human Gene Therapy Clinical Development\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1089/humc.2018.129\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2018/12/4 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q1\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Human Gene Therapy Clinical Development","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1089/humc.2018.129","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2018/12/4 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 7

摘要

2014年西非爆发的埃博拉疫情给全球公共卫生带来了巨大威胁。当时还没有批准的抗病毒疗法或疫苗来控制这种疾病。世界各地正在紧急开发几种埃博拉疫苗。其中,基于2014年扎伊尔几内亚流行毒株的新型重组腺病毒5型载体型埃博拉疫苗(Ad5-EBOV)在中国研制成功,并在中国和塞拉利昂进行了安全性和免疫原性试验。2017年10月19日,中国食品药品监督管理局批准了该药物的上市许可。为规范Ad5-EBOV病毒滴度的检测,根据世界卫生组织和中国药典(第三版)关于制备、鉴定和建立国际及其他生物参考标准的建议,制定了Ad5-EBOV病毒滴度的中国国家标准物质。制备Ad5-EBOV病毒滴度标准品,体积为0.5 mL /安瓿,冻干形式。将不同目的的A、B、C、D标准样品盲法分配到5个实验室进行协同校准。根据Adeno-X™快速滴度试剂盒的说明,用抗体染色法测定本标准品的病毒滴度。标准品的均匀性和稳定性也令人满意。病毒滴度标准值为8.54 lg感染单位(IFU)/mL, 95%可信区间为7.94 ~ 9.14 lg IFU/mL。本标准经中国国家委员会批准,可在美国国家食品药品监督管理研究院网站(www.nifdc.org.cn;很多没有。250019 - 201501)。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Establishing China's National Standard for the Recombinant Adenovirus Type 5 Vector-Based Ebola Vaccine (Ad5-EBOV) Virus Titer.

The 2014 Ebola outbreak in West Africa brought great threat to public health worldwide. There was no approved antiviral therapy or vaccine available to control the disease at that time. Several kinds of Ebola vaccines were urgently under development across the world. Among these, the novel recombinant adenovirus type 5 vector-based Ebola vaccine (Ad5-EBOV)-the first Ebola vaccine based on the 2014 Zaire Guinea epidemic strain-was developed in China, and its safety and immunogenicity were demonstrated in China and Sierra Leone. The license to market the drug was approved on October 19, 2017, by the Chinese Food and Drug Administration. In order to standardize the test on the Ad5-EBOV virus titer, China's national standard substance for the virus titer of Ad5-EBOV was established according to the recommendations for the preparation, characterization, and establishment of international and other biological reference standards from the World Health Organization and Chinese Pharmacopoeia (third edition). The standard for the Ad5-EBOV virus titer was prepared with a volume of 0.5 mL per ampoule in lyophilized form. The samples of the standard, designated as A, B, C, D with different aims, were blinded and distributed to five laboratories to be collaboratively calibrated. The virus titer for this standard was determined with the antibody staining method according to the instructions in the Adeno-X™ Rapid Titer Kit. The homogeneity and stability of the standard substance were also satisfied. The virus titer standard value was 8.54 lg infectious units (IFU)/mL, and the 95% confidence interval was between 7.94 lg IFU/mL and 9.14 lg IFU/mL. This standard was approved by the Chinese national committee and is available on the National Institutes for Food and Drug Control Web site ( www.nifdc.org.cn ; lot no. 250019-201501).

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Human Gene Therapy Clinical Development
Human Gene Therapy Clinical Development CRITICAL CARE MEDICINEMEDICINE, RESEARCH &-MEDICINE, RESEARCH & EXPERIMENTAL
CiteScore
7.20
自引率
0.00%
发文量
0
期刊介绍: Human Gene Therapy (HGT) is the premier, multidisciplinary journal covering all aspects of gene therapy. The Journal publishes important advances in DNA, RNA, cell and immune therapies, validating the latest advances in research and new technologies.
期刊最新文献
MiR-625-5p inhibits cardiac hypertrophy through targeting STAT3 and CaMKII. Circular RNA circVAPA promotes cell proliferation in hepatocellular carcinoma. Gene Therapy Briefs. The influence of murine genetic background in AAV transduction of the mouse brain. Inhibition of miR-203 ameliorates osteoarthritis cartilage degradation in the postmenopausal rat model: involvement of estrogen receptor α.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1