机器人时代的儿科外科:早期经验与比较分析。

Q3 Medicine Pediatria Medica e Chirurgica Pub Date : 2019-01-18 DOI:10.4081/pmc.2019.204
Mario Lima, Eduje Thomas, Neil Di Salvo, Tommaso Gargano, Giovanni Ruggeri
{"title":"机器人时代的儿科外科:早期经验与比较分析。","authors":"Mario Lima,&nbsp;Eduje Thomas,&nbsp;Neil Di Salvo,&nbsp;Tommaso Gargano,&nbsp;Giovanni Ruggeri","doi":"10.4081/pmc.2019.204","DOIUrl":null,"url":null,"abstract":"<p><p>The aim of this study is to present our preliminary experience in robotics and a comparative analysis with conventional Minimally- Invasive Surgery (MIS). Cases operated by da Vinci Xi® System from February 2016 to October 2017 are reviewed retrospectively through demographics, diagnosis-procedure and short-term outcome parameters. A comparison with a matching conventional MIS population was also conducted. 40 robotic procedures were carried out and 112 (out of 3705) non-robotic procedures met inclusion criteria for comparison. Among robotic patients we observed: an average age of 143.5 months, weight of 42.9 Kg, operative and anaesthesia induction time respectively of 116.8 and 34.8 minutes. Furthermore, we observed a 6.1-day length of stay, 2.5% conversion rate and no complications. From the comparison between the groups, no statistical difference emerged in the length of stay, in conversion rates or in complications. A statistical significance was observed in terms of operative time in favour of non-Robotic- System. Our experience has meant to introduce the System in our surgical environment, comparing to the conventional MIS (an already established approach routinely performed at our center). Results have shown comparable safety and feasibility.</p>","PeriodicalId":35535,"journal":{"name":"Pediatria Medica e Chirurgica","volume":"41 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2019-01-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.4081/pmc.2019.204","citationCount":"4","resultStr":"{\"title\":\"Paediatric surgery in the robotic era: early experience and comparative analysis.\",\"authors\":\"Mario Lima,&nbsp;Eduje Thomas,&nbsp;Neil Di Salvo,&nbsp;Tommaso Gargano,&nbsp;Giovanni Ruggeri\",\"doi\":\"10.4081/pmc.2019.204\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The aim of this study is to present our preliminary experience in robotics and a comparative analysis with conventional Minimally- Invasive Surgery (MIS). Cases operated by da Vinci Xi® System from February 2016 to October 2017 are reviewed retrospectively through demographics, diagnosis-procedure and short-term outcome parameters. A comparison with a matching conventional MIS population was also conducted. 40 robotic procedures were carried out and 112 (out of 3705) non-robotic procedures met inclusion criteria for comparison. Among robotic patients we observed: an average age of 143.5 months, weight of 42.9 Kg, operative and anaesthesia induction time respectively of 116.8 and 34.8 minutes. Furthermore, we observed a 6.1-day length of stay, 2.5% conversion rate and no complications. From the comparison between the groups, no statistical difference emerged in the length of stay, in conversion rates or in complications. A statistical significance was observed in terms of operative time in favour of non-Robotic- System. Our experience has meant to introduce the System in our surgical environment, comparing to the conventional MIS (an already established approach routinely performed at our center). Results have shown comparable safety and feasibility.</p>\",\"PeriodicalId\":35535,\"journal\":{\"name\":\"Pediatria Medica e Chirurgica\",\"volume\":\"41 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-01-18\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.4081/pmc.2019.204\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Pediatria Medica e Chirurgica\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.4081/pmc.2019.204\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Pediatria Medica e Chirurgica","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4081/pmc.2019.204","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 4

摘要

本研究的目的是介绍我们在机器人技术方面的初步经验,并与传统的微创手术(MIS)进行比较分析。还进行了与匹配的传统MIS人口的比较。40例机器人手术和112例(3705例中)非机器人手术符合纳入标准进行比较。我们观察到的机器人患者平均年龄143.5个月,体重42.9 Kg,手术诱导时间116.8分钟,麻醉诱导时间34.8分钟。此外,我们观察到6.1天的住院时间,2.5%的转换率和无并发症。从两组之间的比较来看,在住院时间、转换率和并发症方面没有统计学差异。在手术时间方面观察到非机器人系统的统计学意义。我们的经验意味着在我们的手术环境中引入该系统,与传统的MIS(我们中心已经建立的常规方法)相比。结果显示了相当的安全性和可行性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Paediatric surgery in the robotic era: early experience and comparative analysis.

The aim of this study is to present our preliminary experience in robotics and a comparative analysis with conventional Minimally- Invasive Surgery (MIS). Cases operated by da Vinci Xi® System from February 2016 to October 2017 are reviewed retrospectively through demographics, diagnosis-procedure and short-term outcome parameters. A comparison with a matching conventional MIS population was also conducted. 40 robotic procedures were carried out and 112 (out of 3705) non-robotic procedures met inclusion criteria for comparison. Among robotic patients we observed: an average age of 143.5 months, weight of 42.9 Kg, operative and anaesthesia induction time respectively of 116.8 and 34.8 minutes. Furthermore, we observed a 6.1-day length of stay, 2.5% conversion rate and no complications. From the comparison between the groups, no statistical difference emerged in the length of stay, in conversion rates or in complications. A statistical significance was observed in terms of operative time in favour of non-Robotic- System. Our experience has meant to introduce the System in our surgical environment, comparing to the conventional MIS (an already established approach routinely performed at our center). Results have shown comparable safety and feasibility.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Pediatria Medica e Chirurgica
Pediatria Medica e Chirurgica Medicine-Pediatrics, Perinatology and Child Health
CiteScore
0.70
自引率
0.00%
发文量
21
审稿时长
10 weeks
期刊最新文献
Morbidity related to major lung thoracoscopic resections in children. Satisfaction and results of the subareolar incision as treatment for gynecomastia in adolescents: experience of two centers. Are the complications after laparo-assisted endo-rectal pull-through for Hirschsprung disease related to the change of the anal tone? The effect of an educational program on illness uncertainty in mothers of children with type 1 diabetes: a quasi-experimental study. Dysphagia lusoria caused by aberrant right subclavian artery associated with truncus bicaroticus in an 8-month-old girl. Case report and review of literature.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1