Masumeh Hasani Tabatabaei, Nasim Chiniforush, Ghazaleh Hashemi, Sara Valizadeh
{"title":"Nd:YAG激光、二极管激光和牙本质粘接剂治疗牙本质过敏的临床疗效比较。","authors":"Masumeh Hasani Tabatabaei, Nasim Chiniforush, Ghazaleh Hashemi, Sara Valizadeh","doi":"10.5978/islsm.27_18-OR-24","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>Dentin hypersensitivity is characterized by short, sharp pain arising from exposed dentin in response to external stimuli. Several modalities have been suggested for treatment of this condition such as low-level laser therapy (LLLT) and application of dentin bonding agents. The aim of this study was to compare the clinical efficacy of diode laser, Nd:YAG laser and dentin bonding agent for treatment of dentin hypersensitivity.</p><p><strong>Materials and methods: </strong>In this study, 135 teeth of 22 patients diagnosed with dentin hypersensitivity were divided into three groups: In group 1, the teeth were irradiated by diode laser with 810 nm wavelength for 30 seconds and in group 2, the teeth were irradiated by Nd:YAG laser with 1064 nm wavelength for 40 seconds. CLEARFIL SE BOND was applied on teeth in group 3. LLLT was carried out in 3 sessions with 7-day intervals between sessions, during a period of 3 consecutive weeks. Hypersensitivity was assessed by cold test according to the criteria proposed by Uchida at baseline, immediately after treatment and at 1, 3 and 6 months, postoperatively.</p><p><strong>Results: </strong>Reduction of dentin hypersensitivity was observed at 3 and 6 months following the use of Nd:YAG laser <i>(p < 0.001)</i>. Reduction in dentin hypersensitivity was observed immediately after treatment in all groups. Statistically significant differences in level of dentin hypersensitivity were found between groups at 3 and at 6 months <i>(p ≤ 0.001)</i>. The reduction in dentin hypersensitivity by Nd:YAG laser was significantly superior to that in other groups at this time.</p><p><strong>Conclusion: </strong>The efficacy of Nd:YAG laser in reduction of dentin hypersensitivity was significantly superior to that of other modalities at 3 and 6 months.</p>","PeriodicalId":17981,"journal":{"name":"Laser therapy","volume":"27 4","pages":"265-270"},"PeriodicalIF":0.0000,"publicationDate":"2018-12-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.5978/islsm.27_18-OR-24","citationCount":"11","resultStr":"{\"title\":\"Efficacy Comparison of Nd:YAG laser, diode laser and dentine bonding agent in dentine hypersensitivity reduction: a clinical trial.\",\"authors\":\"Masumeh Hasani Tabatabaei, Nasim Chiniforush, Ghazaleh Hashemi, Sara Valizadeh\",\"doi\":\"10.5978/islsm.27_18-OR-24\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>Dentin hypersensitivity is characterized by short, sharp pain arising from exposed dentin in response to external stimuli. Several modalities have been suggested for treatment of this condition such as low-level laser therapy (LLLT) and application of dentin bonding agents. The aim of this study was to compare the clinical efficacy of diode laser, Nd:YAG laser and dentin bonding agent for treatment of dentin hypersensitivity.</p><p><strong>Materials and methods: </strong>In this study, 135 teeth of 22 patients diagnosed with dentin hypersensitivity were divided into three groups: In group 1, the teeth were irradiated by diode laser with 810 nm wavelength for 30 seconds and in group 2, the teeth were irradiated by Nd:YAG laser with 1064 nm wavelength for 40 seconds. CLEARFIL SE BOND was applied on teeth in group 3. LLLT was carried out in 3 sessions with 7-day intervals between sessions, during a period of 3 consecutive weeks. Hypersensitivity was assessed by cold test according to the criteria proposed by Uchida at baseline, immediately after treatment and at 1, 3 and 6 months, postoperatively.</p><p><strong>Results: </strong>Reduction of dentin hypersensitivity was observed at 3 and 6 months following the use of Nd:YAG laser <i>(p < 0.001)</i>. Reduction in dentin hypersensitivity was observed immediately after treatment in all groups. Statistically significant differences in level of dentin hypersensitivity were found between groups at 3 and at 6 months <i>(p ≤ 0.001)</i>. The reduction in dentin hypersensitivity by Nd:YAG laser was significantly superior to that in other groups at this time.</p><p><strong>Conclusion: </strong>The efficacy of Nd:YAG laser in reduction of dentin hypersensitivity was significantly superior to that of other modalities at 3 and 6 months.</p>\",\"PeriodicalId\":17981,\"journal\":{\"name\":\"Laser therapy\",\"volume\":\"27 4\",\"pages\":\"265-270\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-12-31\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.5978/islsm.27_18-OR-24\",\"citationCount\":\"11\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Laser therapy\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.5978/islsm.27_18-OR-24\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Laser therapy","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5978/islsm.27_18-OR-24","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 11
摘要
目的:牙本质过敏的特征是暴露的牙本质对外界刺激产生短暂的尖锐疼痛。目前已经提出了几种治疗方法,如低水平激光治疗(LLLT)和应用牙本质粘接剂。本研究的目的是比较二极管激光、Nd:YAG激光和牙本质粘接剂治疗牙本质过敏的临床疗效。材料与方法:本研究将22例诊断为牙本质过敏的患者135颗牙分为三组,第一组采用波长810 nm的二极管激光照射30秒,第二组采用波长1064 nm的Nd:YAG激光照射40秒。第三组采用CLEARFIL SE BOND。LLLT分3组进行,每组间隔7天,连续3周。根据Uchida提出的标准,在基线、治疗后立即和术后1、3和6个月进行冷试验评估过敏。结果:使用Nd:YAG激光治疗后3、6个月,牙本质过敏症状明显减轻(p < 0.001)。治疗后,各组牙本质过敏反应均明显减轻。3个月和6个月时两组牙本质过敏水平差异有统计学意义(p≤0.001)。Nd:YAG激光对牙本质超敏反应的降低明显优于其他组。结论:Nd:YAG激光治疗牙本质过敏的疗效明显优于其他治疗方式。
Efficacy Comparison of Nd:YAG laser, diode laser and dentine bonding agent in dentine hypersensitivity reduction: a clinical trial.
Purpose: Dentin hypersensitivity is characterized by short, sharp pain arising from exposed dentin in response to external stimuli. Several modalities have been suggested for treatment of this condition such as low-level laser therapy (LLLT) and application of dentin bonding agents. The aim of this study was to compare the clinical efficacy of diode laser, Nd:YAG laser and dentin bonding agent for treatment of dentin hypersensitivity.
Materials and methods: In this study, 135 teeth of 22 patients diagnosed with dentin hypersensitivity were divided into three groups: In group 1, the teeth were irradiated by diode laser with 810 nm wavelength for 30 seconds and in group 2, the teeth were irradiated by Nd:YAG laser with 1064 nm wavelength for 40 seconds. CLEARFIL SE BOND was applied on teeth in group 3. LLLT was carried out in 3 sessions with 7-day intervals between sessions, during a period of 3 consecutive weeks. Hypersensitivity was assessed by cold test according to the criteria proposed by Uchida at baseline, immediately after treatment and at 1, 3 and 6 months, postoperatively.
Results: Reduction of dentin hypersensitivity was observed at 3 and 6 months following the use of Nd:YAG laser (p < 0.001). Reduction in dentin hypersensitivity was observed immediately after treatment in all groups. Statistically significant differences in level of dentin hypersensitivity were found between groups at 3 and at 6 months (p ≤ 0.001). The reduction in dentin hypersensitivity by Nd:YAG laser was significantly superior to that in other groups at this time.
Conclusion: The efficacy of Nd:YAG laser in reduction of dentin hypersensitivity was significantly superior to that of other modalities at 3 and 6 months.