Theragenics AgX-100®I-125种子用于ROPES眼斑近距离治疗的剂量学验证。

Q3 Biochemistry, Genetics and Molecular Biology Australasian Physical & Engineering Sciences in Medicine Pub Date : 2019-06-01 Epub Date: 2019-05-13 DOI:10.1007/s13246-019-00761-6
Claire Pagulayan, Soo Min Heng, Stephanie Corde
{"title":"Theragenics AgX-100®I-125种子用于ROPES眼斑近距离治疗的剂量学验证。","authors":"Claire Pagulayan,&nbsp;Soo Min Heng,&nbsp;Stephanie Corde","doi":"10.1007/s13246-019-00761-6","DOIUrl":null,"url":null,"abstract":"<p><p>With the discontinued distribution of the I-125 Oncura Onco seed (model 6711), the Theragenics AgX100® I-125 seeds were considered as a suitable alternative for eye plaque brachytherapy as their physical properties matched the requirements for use with the ROPES eye plaques. The purpose of this study aims at validating the dosimetry of the AgX-100 loaded ROPES plaques (11 mm diameter, 15 mm diameter with flange, 15 mm diameter with notch, 18 mm diameter) and assess the differences with the discontinued I-125 6711 model. To independently verify the plaque dosimetry, the brachytherapy module of RADCALC® version 6.2.3.6 was commissioned for the new AgX-100 I-125 seed using the published AAPM TG43 data from the literature. Experimental dosimetry verification was performed using EBT3 Gafchromic™ film and TLD-100 micro-cubes in a specially designed Solid Water® phantom. Both RADCALC® and film confirmed the dosimetry calculated by Plaque Simulator (PS) version 6.4.6 The dose calculated by PS agrees with RADCALC® to within 2% for depths of 1-15 mm for the 4 available ROPES plaques. The dosimetric measurements agreed with the calculations of PS for clinically relevant depths (4 mm to 6 mm) within the evaluated uncertainties of 4.7% and 7.2% for EBT3 film and TLDs respectively. The AgX-100 I-125 seed was a suitable replacement for the 6711 I-125 seed. Due to the introduction of the stainless-steel backscatter factor in PS v6.4.6, the department has decided to report both the homogenous dose and heterogeneity corrected dose for each eye plaque patient.</p>","PeriodicalId":55430,"journal":{"name":"Australasian Physical & Engineering Sciences in Medicine","volume":"42 2","pages":"599-609"},"PeriodicalIF":0.0000,"publicationDate":"2019-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1007/s13246-019-00761-6","citationCount":"4","resultStr":"{\"title\":\"Dosimetric validation of the Theragenics AgX-100® I-125 seed for ROPES eye plaque brachytherapy.\",\"authors\":\"Claire Pagulayan,&nbsp;Soo Min Heng,&nbsp;Stephanie Corde\",\"doi\":\"10.1007/s13246-019-00761-6\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>With the discontinued distribution of the I-125 Oncura Onco seed (model 6711), the Theragenics AgX100® I-125 seeds were considered as a suitable alternative for eye plaque brachytherapy as their physical properties matched the requirements for use with the ROPES eye plaques. The purpose of this study aims at validating the dosimetry of the AgX-100 loaded ROPES plaques (11 mm diameter, 15 mm diameter with flange, 15 mm diameter with notch, 18 mm diameter) and assess the differences with the discontinued I-125 6711 model. To independently verify the plaque dosimetry, the brachytherapy module of RADCALC® version 6.2.3.6 was commissioned for the new AgX-100 I-125 seed using the published AAPM TG43 data from the literature. Experimental dosimetry verification was performed using EBT3 Gafchromic™ film and TLD-100 micro-cubes in a specially designed Solid Water® phantom. Both RADCALC® and film confirmed the dosimetry calculated by Plaque Simulator (PS) version 6.4.6 The dose calculated by PS agrees with RADCALC® to within 2% for depths of 1-15 mm for the 4 available ROPES plaques. The dosimetric measurements agreed with the calculations of PS for clinically relevant depths (4 mm to 6 mm) within the evaluated uncertainties of 4.7% and 7.2% for EBT3 film and TLDs respectively. The AgX-100 I-125 seed was a suitable replacement for the 6711 I-125 seed. Due to the introduction of the stainless-steel backscatter factor in PS v6.4.6, the department has decided to report both the homogenous dose and heterogeneity corrected dose for each eye plaque patient.</p>\",\"PeriodicalId\":55430,\"journal\":{\"name\":\"Australasian Physical & Engineering Sciences in Medicine\",\"volume\":\"42 2\",\"pages\":\"599-609\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-06-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1007/s13246-019-00761-6\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Australasian Physical & Engineering Sciences in Medicine\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1007/s13246-019-00761-6\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2019/5/13 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q3\",\"JCRName\":\"Biochemistry, Genetics and Molecular Biology\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Australasian Physical & Engineering Sciences in Medicine","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1007/s13246-019-00761-6","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2019/5/13 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"Biochemistry, Genetics and Molecular Biology","Score":null,"Total":0}
引用次数: 4

摘要

随着I-125 Oncura Onco种子(型号6711)的停止销售,Theragenics AgX100®I-125种子被认为是眼斑近距离治疗的合适替代品,因为它们的物理特性符合使用ROPES眼斑的要求。本研究的目的是验证AgX-100负载的ROPES斑块(11毫米直径,15毫米直径带法兰,15毫米直径带缺口,18毫米直径)的剂量学,并评估其与已停产的I-125 6711模型的差异。为了独立验证斑块剂量学,使用文献中已发表的AAPM TG43数据,为新的AgX-100 I-125种子委托了RADCALC®版本6.2.3.6的近距离治疗模块。实验剂量学验证使用EBT3 Gafchromic™薄膜和TLD-100微立方体在专门设计的Solid Water®模体中进行。RADCALC®和film均证实了斑块模拟器(PS) 6.4.6版计算的剂量。对于4个可用的ROPES斑块,PS计算的剂量与RADCALC®一致,在1- 15mm深度范围内,剂量在2%以内。剂量学测量结果与临床相关深度(4mm至6mm)的PS计算结果一致,评估的不确定度分别为4.7%和7.2%。AgX-100 I-125种子是6711 I-125种子的合适替代品。由于PS v6.4.6中引入了不锈钢后向散射因子,科室决定同时报告每个眼斑患者的均匀剂量和非均匀校正剂量。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Dosimetric validation of the Theragenics AgX-100® I-125 seed for ROPES eye plaque brachytherapy.

With the discontinued distribution of the I-125 Oncura Onco seed (model 6711), the Theragenics AgX100® I-125 seeds were considered as a suitable alternative for eye plaque brachytherapy as their physical properties matched the requirements for use with the ROPES eye plaques. The purpose of this study aims at validating the dosimetry of the AgX-100 loaded ROPES plaques (11 mm diameter, 15 mm diameter with flange, 15 mm diameter with notch, 18 mm diameter) and assess the differences with the discontinued I-125 6711 model. To independently verify the plaque dosimetry, the brachytherapy module of RADCALC® version 6.2.3.6 was commissioned for the new AgX-100 I-125 seed using the published AAPM TG43 data from the literature. Experimental dosimetry verification was performed using EBT3 Gafchromic™ film and TLD-100 micro-cubes in a specially designed Solid Water® phantom. Both RADCALC® and film confirmed the dosimetry calculated by Plaque Simulator (PS) version 6.4.6 The dose calculated by PS agrees with RADCALC® to within 2% for depths of 1-15 mm for the 4 available ROPES plaques. The dosimetric measurements agreed with the calculations of PS for clinically relevant depths (4 mm to 6 mm) within the evaluated uncertainties of 4.7% and 7.2% for EBT3 film and TLDs respectively. The AgX-100 I-125 seed was a suitable replacement for the 6711 I-125 seed. Due to the introduction of the stainless-steel backscatter factor in PS v6.4.6, the department has decided to report both the homogenous dose and heterogeneity corrected dose for each eye plaque patient.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
2.00
自引率
0.00%
发文量
0
审稿时长
6-12 weeks
期刊介绍: Australasian Physical & Engineering Sciences in Medicine (APESM) is a multidisciplinary forum for information and research on the application of physics and engineering to medicine and human physiology. APESM covers a broad range of topics that include but is not limited to: - Medical physics in radiotherapy - Medical physics in diagnostic radiology - Medical physics in nuclear medicine - Mathematical modelling applied to medicine and human biology - Clinical biomedical engineering - Feature extraction, classification of EEG, ECG, EMG, EOG, and other biomedical signals; - Medical imaging - contributions to new and improved methods; - Modelling of physiological systems - Image processing to extract information from images, e.g. fMRI, CT, etc.; - Biomechanics, especially with applications to orthopaedics. - Nanotechnology in medicine APESM offers original reviews, scientific papers, scientific notes, technical papers, educational notes, book reviews and letters to the editor. APESM is the journal of the Australasian College of Physical Scientists and Engineers in Medicine, and also the official journal of the College of Biomedical Engineers, Engineers Australia and the Asia-Oceania Federation of Organizations for Medical Physics.
期刊最新文献
Acknowledgment of Reviewers for Volume 35 Acknowledgment of Reviewers for Volume 34 A comparison between EPSON V700 and EPSON V800 scanners for film dosimetry. Nanodosimetric understanding to the dependence of the relationship between dose-averaged lineal energy on nanoscale and LET on ion species. EPSM 2019, Engineering and Physical Sciences in Medicine : 28-30 October 2019, Perth, Australia.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1