{"title":"通过纳米计量学了解纳米尺度剂量平均线能量与 LET 之间的关系取决于离子种类。","authors":"Tianyuan Dai, Hui Zhang, Xinguo Liu, Zhongying Dai, Pengbo He, Yuanyuan Ma, Guosheng Shen, Weiqiang Chen, Qiang Li","doi":"10.1007/s13246-020-00840-z","DOIUrl":null,"url":null,"abstract":"<p><p>With the extension of ion species in ion-beam radiotherapy, the sole dependence of relative biological effectiveness (RBE) on linear energy transfer (LET) is insufficient when comparing RBE for ion beams with the same LET value. The aim of the present study was to provide a systematic study of the nanodosimetry for ion beams with the same LET value. Based on the calculated LET profiles of ion beams with range about 130 mm, lineal energy spectra and dose-averaged lineal energy [Formula: see text] on 4 nm site for various clinical ion beams were obtained. Then, the lineal energy spectra and [Formula: see text] values were compared for ion beams with the same LET values. The results showed that the relationships between [Formula: see text] and LET for various ion beams present an dependence on ion species. For ion beams with the same LET value, the ion beams with smaller nucleon number yielded greater [Formula: see text] values. The probability of the small-nucleon-number ion beams to generate large energy deposition events on nanoscale was higher than that of the large-nucleon-number ion beams. The dependence of the relationship between RBE and LET on ion species might be attributed to the fluctuation of energy depositions on nanometer scale.</p>","PeriodicalId":55430,"journal":{"name":"Australasian Physical & Engineering Sciences in Medicine","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2020-01-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Nanodosimetric understanding to the dependence of the relationship between dose-averaged lineal energy on nanoscale and LET on ion species.\",\"authors\":\"Tianyuan Dai, Hui Zhang, Xinguo Liu, Zhongying Dai, Pengbo He, Yuanyuan Ma, Guosheng Shen, Weiqiang Chen, Qiang Li\",\"doi\":\"10.1007/s13246-020-00840-z\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>With the extension of ion species in ion-beam radiotherapy, the sole dependence of relative biological effectiveness (RBE) on linear energy transfer (LET) is insufficient when comparing RBE for ion beams with the same LET value. The aim of the present study was to provide a systematic study of the nanodosimetry for ion beams with the same LET value. Based on the calculated LET profiles of ion beams with range about 130 mm, lineal energy spectra and dose-averaged lineal energy [Formula: see text] on 4 nm site for various clinical ion beams were obtained. Then, the lineal energy spectra and [Formula: see text] values were compared for ion beams with the same LET values. The results showed that the relationships between [Formula: see text] and LET for various ion beams present an dependence on ion species. For ion beams with the same LET value, the ion beams with smaller nucleon number yielded greater [Formula: see text] values. The probability of the small-nucleon-number ion beams to generate large energy deposition events on nanoscale was higher than that of the large-nucleon-number ion beams. The dependence of the relationship between RBE and LET on ion species might be attributed to the fluctuation of energy depositions on nanometer scale.</p>\",\"PeriodicalId\":55430,\"journal\":{\"name\":\"Australasian Physical & Engineering Sciences in Medicine\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-01-06\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Australasian Physical & Engineering Sciences in Medicine\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1007/s13246-020-00840-z\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"Biochemistry, Genetics and Molecular Biology\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Australasian Physical & Engineering Sciences in Medicine","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1007/s13246-020-00840-z","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Biochemistry, Genetics and Molecular Biology","Score":null,"Total":0}
引用次数: 0
摘要
随着离子束放射治疗中离子种类的增加,在比较具有相同 LET 值的离子束的相对生物效应(RBE)时,仅依赖线性能量传递(LET)是不够的。本研究旨在对具有相同 LET 值的离子束的纳米模拟进行系统研究。根据范围约为 130 mm 的离子束的计算 LET 曲线,获得了各种临床离子束在 4 nm 位点上的线性能量谱和剂量平均线性能量[公式:见正文]。然后,比较了具有相同 LET 值的离子束的线能谱和[公式:见正文]值。结果表明,各种离子束的[计算公式:见正文]和 LET 之间的关系与离子种类有关。对于 LET 值相同的离子束,核子数较小的离子束产生的[公式:见正文]值较大。小核子数离子束在纳米尺度上产生大能量沉积事件的概率高于大核子数离子束。RBE 与 LET 之间的关系取决于离子种类,这可能是由于纳米尺度上的能量沉积波动所致。
Nanodosimetric understanding to the dependence of the relationship between dose-averaged lineal energy on nanoscale and LET on ion species.
With the extension of ion species in ion-beam radiotherapy, the sole dependence of relative biological effectiveness (RBE) on linear energy transfer (LET) is insufficient when comparing RBE for ion beams with the same LET value. The aim of the present study was to provide a systematic study of the nanodosimetry for ion beams with the same LET value. Based on the calculated LET profiles of ion beams with range about 130 mm, lineal energy spectra and dose-averaged lineal energy [Formula: see text] on 4 nm site for various clinical ion beams were obtained. Then, the lineal energy spectra and [Formula: see text] values were compared for ion beams with the same LET values. The results showed that the relationships between [Formula: see text] and LET for various ion beams present an dependence on ion species. For ion beams with the same LET value, the ion beams with smaller nucleon number yielded greater [Formula: see text] values. The probability of the small-nucleon-number ion beams to generate large energy deposition events on nanoscale was higher than that of the large-nucleon-number ion beams. The dependence of the relationship between RBE and LET on ion species might be attributed to the fluctuation of energy depositions on nanometer scale.
期刊介绍:
Australasian Physical & Engineering Sciences in Medicine (APESM) is a multidisciplinary forum for information and research on the application of physics and engineering to medicine and human physiology. APESM covers a broad range of topics that include but is not limited to:
- Medical physics in radiotherapy
- Medical physics in diagnostic radiology
- Medical physics in nuclear medicine
- Mathematical modelling applied to medicine and human biology
- Clinical biomedical engineering
- Feature extraction, classification of EEG, ECG, EMG, EOG, and other biomedical signals;
- Medical imaging - contributions to new and improved methods;
- Modelling of physiological systems
- Image processing to extract information from images, e.g. fMRI, CT, etc.;
- Biomechanics, especially with applications to orthopaedics.
- Nanotechnology in medicine
APESM offers original reviews, scientific papers, scientific notes, technical papers, educational notes, book reviews and letters to the editor.
APESM is the journal of the Australasian College of Physical Scientists and Engineers in Medicine, and also the official journal of the College of Biomedical Engineers, Engineers Australia and the Asia-Oceania Federation of Organizations for Medical Physics.