单光子发射计算机断层扫描示踪剂。

Hans-Jürgen Pietzsch, Constantin Mamat, Cristina Müller, Roger Schibli
{"title":"单光子发射计算机断层扫描示踪剂。","authors":"Hans-Jürgen Pietzsch,&nbsp;Constantin Mamat,&nbsp;Cristina Müller,&nbsp;Roger Schibli","doi":"10.1007/978-3-030-42618-7_7","DOIUrl":null,"url":null,"abstract":"<p><p>Single photon emission computed tomography (SPECT) is the state-of-the-art imaging modality in nuclear medicine despite the fact that only a few new SPECT tracers have become available in the past 20 years. Critical for the future success of SPECT is the design of new and specific tracers for the detection, localization, and staging of a disease and for monitoring therapy. The utility of SPECT imaging to address oncologic questions is dependent on radiotracers that ideally exhibit excellent tissue penetration, high affinity to the tumor-associated target structure, specific uptake and retention in the malignant lesions, and rapid clearance from non-targeted tissues and organs. In general, a target-specific SPECT radiopharmaceutical can be divided into two main parts: a targeting biomolecule (e.g., peptide, antibody fragment) and a γ-radiation-emitting radionuclide (e.g., <sup>99m</sup>Tc, <sup>123</sup>I). If radiometals are used as the radiation source, a bifunctional chelator is needed to link the radioisotope to the targeting entity. In a rational SPECT tracer design, these single components have to be critically evaluated in order to achieve a balance among the demands for adequate target binding, and a rapid clearance of the radiotracer. The focus of this chapter is to depict recent developments of tumor-targeted SPECT radiotracers for imaging of cancer diseases. Possibilities for optimization of tracer design and potential causes for design failure are discussed and highlighted with selected examples.</p>","PeriodicalId":39880,"journal":{"name":"Recent Results in Cancer Research","volume":"216 ","pages":"227-282"},"PeriodicalIF":0.0000,"publicationDate":"2020-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Single Photon Emission Computed Tomography Tracer.\",\"authors\":\"Hans-Jürgen Pietzsch,&nbsp;Constantin Mamat,&nbsp;Cristina Müller,&nbsp;Roger Schibli\",\"doi\":\"10.1007/978-3-030-42618-7_7\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Single photon emission computed tomography (SPECT) is the state-of-the-art imaging modality in nuclear medicine despite the fact that only a few new SPECT tracers have become available in the past 20 years. Critical for the future success of SPECT is the design of new and specific tracers for the detection, localization, and staging of a disease and for monitoring therapy. The utility of SPECT imaging to address oncologic questions is dependent on radiotracers that ideally exhibit excellent tissue penetration, high affinity to the tumor-associated target structure, specific uptake and retention in the malignant lesions, and rapid clearance from non-targeted tissues and organs. In general, a target-specific SPECT radiopharmaceutical can be divided into two main parts: a targeting biomolecule (e.g., peptide, antibody fragment) and a γ-radiation-emitting radionuclide (e.g., <sup>99m</sup>Tc, <sup>123</sup>I). If radiometals are used as the radiation source, a bifunctional chelator is needed to link the radioisotope to the targeting entity. In a rational SPECT tracer design, these single components have to be critically evaluated in order to achieve a balance among the demands for adequate target binding, and a rapid clearance of the radiotracer. The focus of this chapter is to depict recent developments of tumor-targeted SPECT radiotracers for imaging of cancer diseases. Possibilities for optimization of tracer design and potential causes for design failure are discussed and highlighted with selected examples.</p>\",\"PeriodicalId\":39880,\"journal\":{\"name\":\"Recent Results in Cancer Research\",\"volume\":\"216 \",\"pages\":\"227-282\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Recent Results in Cancer Research\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1007/978-3-030-42618-7_7\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Recent Results in Cancer Research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1007/978-3-030-42618-7_7","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 2

摘要

单光子发射计算机断层扫描(SPECT)是核医学中最先进的成像方式,尽管在过去的20年里只有少数新的SPECT示踪剂可用。SPECT未来成功的关键是设计新的特异性示踪剂,用于疾病的检测、定位和分期以及监测治疗。SPECT成像解决肿瘤学问题的效用依赖于放射性示踪剂,这些示踪剂理想地表现出优异的组织穿透性,对肿瘤相关靶结构的高亲和力,在恶性病变中的特异性摄取和保留,以及从非靶向组织和器官的快速清除。一般来说,靶向性SPECT放射性药物可分为两个主要部分:靶向生物分子(如肽、抗体片段)和γ辐射发射放射性核素(如99mTc、123I)。如果使用放射性金属作为辐射源,则需要双功能螯合剂将放射性同位素与目标实体连接起来。在合理的SPECT示踪剂设计中,必须对这些单一组分进行严格评估,以便在充分结合目标和快速清除放射性示踪剂的需求之间取得平衡。本章的重点是描述肿瘤靶向SPECT放射性示踪剂用于癌症疾病成像的最新进展。优化示踪剂设计的可能性和设计失败的潜在原因进行了讨论,并通过选定的例子强调。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Single Photon Emission Computed Tomography Tracer.

Single photon emission computed tomography (SPECT) is the state-of-the-art imaging modality in nuclear medicine despite the fact that only a few new SPECT tracers have become available in the past 20 years. Critical for the future success of SPECT is the design of new and specific tracers for the detection, localization, and staging of a disease and for monitoring therapy. The utility of SPECT imaging to address oncologic questions is dependent on radiotracers that ideally exhibit excellent tissue penetration, high affinity to the tumor-associated target structure, specific uptake and retention in the malignant lesions, and rapid clearance from non-targeted tissues and organs. In general, a target-specific SPECT radiopharmaceutical can be divided into two main parts: a targeting biomolecule (e.g., peptide, antibody fragment) and a γ-radiation-emitting radionuclide (e.g., 99mTc, 123I). If radiometals are used as the radiation source, a bifunctional chelator is needed to link the radioisotope to the targeting entity. In a rational SPECT tracer design, these single components have to be critically evaluated in order to achieve a balance among the demands for adequate target binding, and a rapid clearance of the radiotracer. The focus of this chapter is to depict recent developments of tumor-targeted SPECT radiotracers for imaging of cancer diseases. Possibilities for optimization of tracer design and potential causes for design failure are discussed and highlighted with selected examples.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
5.60
自引率
0.00%
发文量
0
期刊最新文献
Surgery. RAW ATTITUDES: Socio-Cultures, Altered Landscapes, and Changing Perceptions of an Underestimated Disease. Opisthorchis viverrini Life Cycle, Distribution, Systematics, and Population Genetics. Pathology of Cholangiocarcinoma. Digital Innovations (Isan Cohort).
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1