认知正常个体、轻度认知障碍和阿尔茨海默病患者使用18F-PI2260进行Tau PET成像的成像窗口评估。

IF 2.2 4区 医学 Q3 BIOCHEMICAL RESEARCH METHODS Molecular Imaging Pub Date : 2020-01-01 DOI:10.1177/1536012120947582
Chanisa Chotipanich, Monchaya Nivorn, Anchisa Kunawudhi, Chetsadaporn Promteangtrong, Natphimol Boonkawin, Attapon Jantarato
{"title":"认知正常个体、轻度认知障碍和阿尔茨海默病患者使用18F-PI2260进行Tau PET成像的成像窗口评估。","authors":"Chanisa Chotipanich,&nbsp;Monchaya Nivorn,&nbsp;Anchisa Kunawudhi,&nbsp;Chetsadaporn Promteangtrong,&nbsp;Natphimol Boonkawin,&nbsp;Attapon Jantarato","doi":"10.1177/1536012120947582","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>The study aimed to evaluate the appropriate uptake-timing in cognitively normal individuals, mild cognitive impairment (MCI), and Alzheimer's disease (AD) patients, using <sup>18</sup>F-PI 2620 dynamic PET acquisition.</p><p><strong>Methods: </strong>Thirty-four MCI patients, 6 AD patients, and 24 cognitively normal individuals were enrolled in this study. A dynamic <sup>18</sup>F-PI 2620 PET study was conducted at 30-75 minutes post-injection in these groups. Co-registration was applied between the dynamic acquisition PET and T1-weighted MRI to delineate various cortical regions. The standardized uptake value ratio (SUVR) was used for quantitative analysis. P-mod software with the Automated Anatomical Labeling (AAL)-merged atlas was employed to generate automatic volumes of interest for 11 brain regions.</p><p><strong>Results: </strong>The curves in most brain regions presented an average SUVR stability at 30-40 minutes post-injection in each group. The appropriate uptake-timing interval of <sup>18</sup>F-PI 2620 was 30-75 minutes post injection for AD group and 30-40 minutes post injection for both cognitively normal individuals and MCI groups.</p><p><strong>Conclusion: </strong>Short uptake time around 30-40 minutes post-injection would be more comfortable and convenient for all patients, especially in those with dementia who were unable to stay motionless for long periods of scanning time in the scanner.</p>","PeriodicalId":18855,"journal":{"name":"Molecular Imaging","volume":null,"pages":null},"PeriodicalIF":2.2000,"publicationDate":"2020-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1177/1536012120947582","citationCount":"9","resultStr":"{\"title\":\"Evaluation of Imaging Windows for Tau PET Imaging Using <sup>18</sup>F-PI2620 in Cognitively Normal Individuals, Mild Cognitive Impairment, and Alzheimer's Disease Patients.\",\"authors\":\"Chanisa Chotipanich,&nbsp;Monchaya Nivorn,&nbsp;Anchisa Kunawudhi,&nbsp;Chetsadaporn Promteangtrong,&nbsp;Natphimol Boonkawin,&nbsp;Attapon Jantarato\",\"doi\":\"10.1177/1536012120947582\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>The study aimed to evaluate the appropriate uptake-timing in cognitively normal individuals, mild cognitive impairment (MCI), and Alzheimer's disease (AD) patients, using <sup>18</sup>F-PI 2620 dynamic PET acquisition.</p><p><strong>Methods: </strong>Thirty-four MCI patients, 6 AD patients, and 24 cognitively normal individuals were enrolled in this study. A dynamic <sup>18</sup>F-PI 2620 PET study was conducted at 30-75 minutes post-injection in these groups. Co-registration was applied between the dynamic acquisition PET and T1-weighted MRI to delineate various cortical regions. The standardized uptake value ratio (SUVR) was used for quantitative analysis. P-mod software with the Automated Anatomical Labeling (AAL)-merged atlas was employed to generate automatic volumes of interest for 11 brain regions.</p><p><strong>Results: </strong>The curves in most brain regions presented an average SUVR stability at 30-40 minutes post-injection in each group. The appropriate uptake-timing interval of <sup>18</sup>F-PI 2620 was 30-75 minutes post injection for AD group and 30-40 minutes post injection for both cognitively normal individuals and MCI groups.</p><p><strong>Conclusion: </strong>Short uptake time around 30-40 minutes post-injection would be more comfortable and convenient for all patients, especially in those with dementia who were unable to stay motionless for long periods of scanning time in the scanner.</p>\",\"PeriodicalId\":18855,\"journal\":{\"name\":\"Molecular Imaging\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":2.2000,\"publicationDate\":\"2020-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1177/1536012120947582\",\"citationCount\":\"9\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Molecular Imaging\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1177/1536012120947582\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"BIOCHEMICAL RESEARCH METHODS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Molecular Imaging","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1177/1536012120947582","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"BIOCHEMICAL RESEARCH METHODS","Score":null,"Total":0}
引用次数: 9

摘要

背景:本研究旨在使用18F-PI 2620动态PET采集来评估认知正常个体、轻度认知障碍(MCI)和阿尔茨海默病(AD)患者的适当摄取时间。方法:34名MCI患者、6名AD患者和24名认知正常人参加了本研究。在这些组中,在注射后30-75分钟进行18F-PI 2620 PET的动态研究。在动态采集PET和T1加权MRI之间应用配准来描绘不同的皮层区域。采用标准化摄取值比值(SUVR)进行定量分析。P-mod软件与自动解剖标记(AAL)合并图谱用于生成11个大脑区域的自动感兴趣体积。结果:各组大多数脑区的曲线在注射后30-40分钟呈现平均SUVR稳定性。对于AD组,18F-PI 2620的适当摄取时间间隔为注射后30-75分钟,对于认知正常个体和MCI组,摄取时间间隔均为注射后30-40分钟。结论:注射后30-40分钟左右的短摄取时间对所有患者来说都更舒适、更方便,尤其是那些无法在扫描仪中长时间保持静止的痴呆症患者。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

摘要图片

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Evaluation of Imaging Windows for Tau PET Imaging Using 18F-PI2620 in Cognitively Normal Individuals, Mild Cognitive Impairment, and Alzheimer's Disease Patients.

Background: The study aimed to evaluate the appropriate uptake-timing in cognitively normal individuals, mild cognitive impairment (MCI), and Alzheimer's disease (AD) patients, using 18F-PI 2620 dynamic PET acquisition.

Methods: Thirty-four MCI patients, 6 AD patients, and 24 cognitively normal individuals were enrolled in this study. A dynamic 18F-PI 2620 PET study was conducted at 30-75 minutes post-injection in these groups. Co-registration was applied between the dynamic acquisition PET and T1-weighted MRI to delineate various cortical regions. The standardized uptake value ratio (SUVR) was used for quantitative analysis. P-mod software with the Automated Anatomical Labeling (AAL)-merged atlas was employed to generate automatic volumes of interest for 11 brain regions.

Results: The curves in most brain regions presented an average SUVR stability at 30-40 minutes post-injection in each group. The appropriate uptake-timing interval of 18F-PI 2620 was 30-75 minutes post injection for AD group and 30-40 minutes post injection for both cognitively normal individuals and MCI groups.

Conclusion: Short uptake time around 30-40 minutes post-injection would be more comfortable and convenient for all patients, especially in those with dementia who were unable to stay motionless for long periods of scanning time in the scanner.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Molecular Imaging
Molecular Imaging Biochemistry, Genetics and Molecular Biology-Biotechnology
自引率
3.60%
发文量
21
期刊介绍: Molecular Imaging is a peer-reviewed, open access journal highlighting the breadth of molecular imaging research from basic science to preclinical studies to human applications. This serves both the scientific and clinical communities by disseminating novel results and concepts relevant to the biological study of normal and disease processes in both basic and translational studies ranging from mice to humans.
期刊最新文献
Comparison of Tumor Non-specific and PD-L1 Specific Imaging by Near-Infrared Fluorescence/Cerenkov Luminescence Dual-Modality In-situ Imaging. Study on the Relationship Between MRI Functional Imaging and Multiple Immunohistochemical Features of Glioma: A Noninvasive and More Precise Glioma Management. PET/CT in the Evaluation of CAR-T Cell Immunotherapy in Hematological Malignancies. Combining Nuclear Medicine With Other Modalities: Future Prospect for Multimodality Imaging. Optical and MRI Multimodal Tracing of Stem Cells In Vivo
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1