夜间血压和睡眠质量在高血压治疗中的作用。

IF 3.2 Q2 CARDIAC & CARDIOVASCULAR SYSTEMS European Cardiology Review Pub Date : 2020-08-24 eCollection Date: 2020-02-01 DOI:10.15420/ecr.2020.13
Francesco P Cappuccio
{"title":"夜间血压和睡眠质量在高血压治疗中的作用。","authors":"Francesco P Cappuccio","doi":"10.15420/ecr.2020.13","DOIUrl":null,"url":null,"abstract":"<p><p>The accurate measurement, prediction and treatment of high blood pressure (BP) are essential to the management of hypertension and the prevention of its associated cardiovascular (CV) risks. However, even if BP is optimally controlled during the day, nocturnal high blood pressure may still increase the risk of CV events. The pattern of circadian rhythm of BP can be evaluated by ambulatory BP monitoring (ABPM). Night-time ABPM is more closely associated with fatal and nonfatal CV events than daytime ambulatory BP. However, the use of ABPM is limited by low availability and the fact that it can cause sleep disturbance, therefore may not provide realistic nocturnal measurements. Home blood pressure monitoring (HBPM) offers an inexpensive alternative to ABPM, is preferred by patients and provides a more realistic assessment of BP during an individual's daily life. However, until recently, HBPM did not offer the possibility to measure nocturnal (sleep time) BP. The development and validation of new BP devices, such as the NightView (OMRON Healthcare, HEM9601T-E3) HBPM device, could overcome these limitations, offering the possibility of daytime and night-time BP measurements with minimal sleep disturbance.</p>","PeriodicalId":45957,"journal":{"name":"European Cardiology Review","volume":"15 ","pages":"e60"},"PeriodicalIF":3.2000,"publicationDate":"2020-08-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/54/5f/ecr-15-e60.PMC7479543.pdf","citationCount":"4","resultStr":"{\"title\":\"The Role of Nocturnal Blood Pressure and Sleep Quality in Hypertension Management.\",\"authors\":\"Francesco P Cappuccio\",\"doi\":\"10.15420/ecr.2020.13\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The accurate measurement, prediction and treatment of high blood pressure (BP) are essential to the management of hypertension and the prevention of its associated cardiovascular (CV) risks. However, even if BP is optimally controlled during the day, nocturnal high blood pressure may still increase the risk of CV events. The pattern of circadian rhythm of BP can be evaluated by ambulatory BP monitoring (ABPM). Night-time ABPM is more closely associated with fatal and nonfatal CV events than daytime ambulatory BP. However, the use of ABPM is limited by low availability and the fact that it can cause sleep disturbance, therefore may not provide realistic nocturnal measurements. Home blood pressure monitoring (HBPM) offers an inexpensive alternative to ABPM, is preferred by patients and provides a more realistic assessment of BP during an individual's daily life. However, until recently, HBPM did not offer the possibility to measure nocturnal (sleep time) BP. The development and validation of new BP devices, such as the NightView (OMRON Healthcare, HEM9601T-E3) HBPM device, could overcome these limitations, offering the possibility of daytime and night-time BP measurements with minimal sleep disturbance.</p>\",\"PeriodicalId\":45957,\"journal\":{\"name\":\"European Cardiology Review\",\"volume\":\"15 \",\"pages\":\"e60\"},\"PeriodicalIF\":3.2000,\"publicationDate\":\"2020-08-24\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/54/5f/ecr-15-e60.PMC7479543.pdf\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"European Cardiology Review\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.15420/ecr.2020.13\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2020/2/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"Q2\",\"JCRName\":\"CARDIAC & CARDIOVASCULAR SYSTEMS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"European Cardiology Review","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.15420/ecr.2020.13","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2020/2/1 0:00:00","PubModel":"eCollection","JCR":"Q2","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 4

摘要

准确测量、预测和治疗高血压(BP)对高血压的管理及其相关心血管(CV)风险的预防至关重要。然而,即使血压在白天得到最佳控制,夜间高血压仍可能增加心血管事件的风险。动态血压监测(ABPM)可以评价血压昼夜节律模式。与日间动态血压相比,夜间ABPM与致死性和非致死性心血管事件的关系更为密切。然而,ABPM的使用受到低可用性和它可能引起睡眠障碍的事实的限制,因此可能无法提供实际的夜间测量。家庭血压监测(HBPM)提供了一种廉价的替代ABPM的方法,是患者的首选,并且在个人日常生活中提供了更现实的血压评估。然而,直到最近,HBPM还没有提供测量夜间(睡眠时间)血压的可能性。夜景(OMRON Healthcare, HEM9601T-E3) HBPM设备等新型血压设备的开发和验证可以克服这些限制,在最小的睡眠干扰下提供白昼夜血压测量的可能性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
The Role of Nocturnal Blood Pressure and Sleep Quality in Hypertension Management.

The accurate measurement, prediction and treatment of high blood pressure (BP) are essential to the management of hypertension and the prevention of its associated cardiovascular (CV) risks. However, even if BP is optimally controlled during the day, nocturnal high blood pressure may still increase the risk of CV events. The pattern of circadian rhythm of BP can be evaluated by ambulatory BP monitoring (ABPM). Night-time ABPM is more closely associated with fatal and nonfatal CV events than daytime ambulatory BP. However, the use of ABPM is limited by low availability and the fact that it can cause sleep disturbance, therefore may not provide realistic nocturnal measurements. Home blood pressure monitoring (HBPM) offers an inexpensive alternative to ABPM, is preferred by patients and provides a more realistic assessment of BP during an individual's daily life. However, until recently, HBPM did not offer the possibility to measure nocturnal (sleep time) BP. The development and validation of new BP devices, such as the NightView (OMRON Healthcare, HEM9601T-E3) HBPM device, could overcome these limitations, offering the possibility of daytime and night-time BP measurements with minimal sleep disturbance.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
European Cardiology Review
European Cardiology Review CARDIAC & CARDIOVASCULAR SYSTEMS-
CiteScore
5.40
自引率
0.00%
发文量
23
审稿时长
12 weeks
期刊最新文献
Clinical Management of Non-alcoholic Steatohepatitis and the Role of the Cardiologist Evidence-based Management of Left Main Coronary Artery Disease Selection of Non-vitamin K Antagonist Oral Anticoagulant for Stroke Prevention in Atrial Fibrillation Based on Patient Profile: Perspectives from Vietnamese Experts. Part 2 Selection of Non-vitamin K Antagonist Oral Anticoagulant for Stroke Prevention in Atrial Fibrillation Based on Patient Profile: Perspectives from Vietnamese Experts. Part 1 The Evolution of Coronary Artery Spasm: How the Pendulum Has Swung
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1