婴幼儿主动脉弓异常超声筛查与诊断的观点与方法探讨。

IF 1.9 3区 医学 Q3 CARDIAC & CARDIOVASCULAR SYSTEMS Cardiovascular Ultrasound Pub Date : 2021-01-14 DOI:10.1186/s12947-021-00237-2
Xinjian He, Jiaoyang Chen, Gaoyang Li
{"title":"婴幼儿主动脉弓异常超声筛查与诊断的观点与方法探讨。","authors":"Xinjian He,&nbsp;Jiaoyang Chen,&nbsp;Gaoyang Li","doi":"10.1186/s12947-021-00237-2","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>The purpose of this study was to explore echocardiographic views and methods of aortic arch anomalies in infants, so as to improve the screening sensitivity and diagnostic accuracy.</p><p><strong>Methods: </strong>140 children with abnormal aortic arch diagnosed by ultrasound in Children's Hospital of Hebei Province from January 2014 to December 2019 were selected for retrospective analysis. All were confirmed by surgery or/and computerized tomography angiography. Series of views for aortic arch (the three-vessel and tracheal view, aortic arch short axis view, left aortic arch long axis view, aortic arch long axis continuous scan views) were performed in all cases on the basis of the routine views of echocardiography. The screening sensitivity and diagnostic coincidence rate of different echocardiographic views for aortic arch anomalies were analyzed.</p><p><strong>Results: </strong>Among the 140 infants, right aortic arch were 21 cases (6/21 were accompanied by mirror branch and 15/21 were with aberrant left subclavian artery). Left aortic arch with aberrant right subclavian artery were 2 cases, and double aortic arch with both arches open were 20 cases. Double aortic arch with left arch atresia were 2 cases, and atresia of the proximal aorta with aortic arch dysplasia was 1 case. Coarctation of the aorta were 67 cases, and interruption of aortic arch were 27 cases. All the patients were correctly diagnosed except that 2 infants with interruption of aortic arch were incorrectly diagnosed as coarctation of the aorta, and 1 infant with coarctation of the aorta was misdiagnosed as interruption of aortic arch by echocardiography. The screening sensitivities of four views and four-view combination for abnormal aortic arch were 99.3, 73.6, 87.1, 99.3, and 100%; the diagnostic coincidence rates were 85.7, 27.1,66.4, 95.0%, and 97.9% respectively. On the basis of traditional left aortic long axis view, other three views had their own advantages. The screening sensitivity and diagnostic coincidence rate of four-view combination were significantly improved.</p><p><strong>Conclusions: </strong>The three-vessel trachea view is simple and feasible, which is suitable for screening abnormal aortic arch. The combination of four views conduces to improving screening sensitivity and diagnostic accuracy of aortic arch abnormalities.</p>","PeriodicalId":9613,"journal":{"name":"Cardiovascular Ultrasound","volume":"19 1","pages":"8"},"PeriodicalIF":1.9000,"publicationDate":"2021-01-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1186/s12947-021-00237-2","citationCount":"2","resultStr":"{\"title\":\"Study on the views and methods of ultrasonic screening and diagnosis for abnormal aortic arch in infants.\",\"authors\":\"Xinjian He,&nbsp;Jiaoyang Chen,&nbsp;Gaoyang Li\",\"doi\":\"10.1186/s12947-021-00237-2\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>The purpose of this study was to explore echocardiographic views and methods of aortic arch anomalies in infants, so as to improve the screening sensitivity and diagnostic accuracy.</p><p><strong>Methods: </strong>140 children with abnormal aortic arch diagnosed by ultrasound in Children's Hospital of Hebei Province from January 2014 to December 2019 were selected for retrospective analysis. All were confirmed by surgery or/and computerized tomography angiography. Series of views for aortic arch (the three-vessel and tracheal view, aortic arch short axis view, left aortic arch long axis view, aortic arch long axis continuous scan views) were performed in all cases on the basis of the routine views of echocardiography. The screening sensitivity and diagnostic coincidence rate of different echocardiographic views for aortic arch anomalies were analyzed.</p><p><strong>Results: </strong>Among the 140 infants, right aortic arch were 21 cases (6/21 were accompanied by mirror branch and 15/21 were with aberrant left subclavian artery). Left aortic arch with aberrant right subclavian artery were 2 cases, and double aortic arch with both arches open were 20 cases. Double aortic arch with left arch atresia were 2 cases, and atresia of the proximal aorta with aortic arch dysplasia was 1 case. Coarctation of the aorta were 67 cases, and interruption of aortic arch were 27 cases. All the patients were correctly diagnosed except that 2 infants with interruption of aortic arch were incorrectly diagnosed as coarctation of the aorta, and 1 infant with coarctation of the aorta was misdiagnosed as interruption of aortic arch by echocardiography. The screening sensitivities of four views and four-view combination for abnormal aortic arch were 99.3, 73.6, 87.1, 99.3, and 100%; the diagnostic coincidence rates were 85.7, 27.1,66.4, 95.0%, and 97.9% respectively. On the basis of traditional left aortic long axis view, other three views had their own advantages. The screening sensitivity and diagnostic coincidence rate of four-view combination were significantly improved.</p><p><strong>Conclusions: </strong>The three-vessel trachea view is simple and feasible, which is suitable for screening abnormal aortic arch. The combination of four views conduces to improving screening sensitivity and diagnostic accuracy of aortic arch abnormalities.</p>\",\"PeriodicalId\":9613,\"journal\":{\"name\":\"Cardiovascular Ultrasound\",\"volume\":\"19 1\",\"pages\":\"8\"},\"PeriodicalIF\":1.9000,\"publicationDate\":\"2021-01-14\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1186/s12947-021-00237-2\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Cardiovascular Ultrasound\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1186/s12947-021-00237-2\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"CARDIAC & CARDIOVASCULAR SYSTEMS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Cardiovascular Ultrasound","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1186/s12947-021-00237-2","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 2

摘要

背景:本研究旨在探讨婴幼儿主动脉弓异常的超声心动图表现及方法,以提高其筛查敏感性和诊断准确性。方法:选取2014年1月至2019年12月河北省儿童医院超声诊断的主动脉弓异常患儿140例进行回顾性分析。所有患者均经手术或/和计算机断层血管造影证实。所有病例均在常规超声心动图的基础上,行主动脉弓三血管及气管图、主动脉弓短轴图、左主动脉弓长轴图、主动脉弓长轴连续扫描图。分析不同超声心动图对主动脉弓异常的筛查敏感性和诊断符合率。结果:140例患儿中,右主动脉弓21例(6/21伴镜支,15/21伴左锁骨下动脉异常)。左主动脉弓伴右锁骨下动脉异常2例,双主动脉弓双开20例。双主动脉弓合并左主动脉弓闭锁2例,近端主动脉弓闭锁合并主动脉弓发育不良1例。主动脉缩窄67例,主动脉弓中断27例。除2例主动脉弓中断患儿被超声心动图误诊为主动脉缩窄外,1例主动脉弓狭窄患儿被超声心动图误诊为主动脉弓中断。四观及四观联合对异常主动脉弓的筛查敏感性分别为99.3、73.6、87.1、99.3、100%;诊断符合率分别为85.7、27.1、66.4、95.0%、97.9%。在传统左主动脉长轴观的基础上,其他三种观各有优势。四观联合的筛查灵敏度和诊断符合率均有显著提高。结论:气管三血管显像简单可行,适用于异常主动脉弓的筛查。四观结合有助于提高主动脉弓异常的筛查敏感性和诊断准确性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

摘要图片

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Study on the views and methods of ultrasonic screening and diagnosis for abnormal aortic arch in infants.

Background: The purpose of this study was to explore echocardiographic views and methods of aortic arch anomalies in infants, so as to improve the screening sensitivity and diagnostic accuracy.

Methods: 140 children with abnormal aortic arch diagnosed by ultrasound in Children's Hospital of Hebei Province from January 2014 to December 2019 were selected for retrospective analysis. All were confirmed by surgery or/and computerized tomography angiography. Series of views for aortic arch (the three-vessel and tracheal view, aortic arch short axis view, left aortic arch long axis view, aortic arch long axis continuous scan views) were performed in all cases on the basis of the routine views of echocardiography. The screening sensitivity and diagnostic coincidence rate of different echocardiographic views for aortic arch anomalies were analyzed.

Results: Among the 140 infants, right aortic arch were 21 cases (6/21 were accompanied by mirror branch and 15/21 were with aberrant left subclavian artery). Left aortic arch with aberrant right subclavian artery were 2 cases, and double aortic arch with both arches open were 20 cases. Double aortic arch with left arch atresia were 2 cases, and atresia of the proximal aorta with aortic arch dysplasia was 1 case. Coarctation of the aorta were 67 cases, and interruption of aortic arch were 27 cases. All the patients were correctly diagnosed except that 2 infants with interruption of aortic arch were incorrectly diagnosed as coarctation of the aorta, and 1 infant with coarctation of the aorta was misdiagnosed as interruption of aortic arch by echocardiography. The screening sensitivities of four views and four-view combination for abnormal aortic arch were 99.3, 73.6, 87.1, 99.3, and 100%; the diagnostic coincidence rates were 85.7, 27.1,66.4, 95.0%, and 97.9% respectively. On the basis of traditional left aortic long axis view, other three views had their own advantages. The screening sensitivity and diagnostic coincidence rate of four-view combination were significantly improved.

Conclusions: The three-vessel trachea view is simple and feasible, which is suitable for screening abnormal aortic arch. The combination of four views conduces to improving screening sensitivity and diagnostic accuracy of aortic arch abnormalities.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Cardiovascular Ultrasound
Cardiovascular Ultrasound CARDIAC & CARDIOVASCULAR SYSTEMS-
CiteScore
4.10
自引率
0.00%
发文量
28
审稿时长
>12 weeks
期刊介绍: Cardiovascular Ultrasound is an online journal, publishing peer-reviewed: original research; authoritative reviews; case reports on challenging and/or unusual diagnostic aspects; and expert opinions on new techniques and technologies. We are particularly interested in articles that include relevant images or video files, which provide an additional dimension to published articles and enhance understanding. As an open access journal, Cardiovascular Ultrasound ensures high visibility for authors in addition to providing an up-to-date and freely available resource for the community. The journal welcomes discussion, and provides a forum for publishing opinion and debate ranging from biology to engineering to clinical echocardiography, with both speed and versatility.
期刊最新文献
Left atrial strain in patients without cardiovascular disease: uncovering influencing and related factors. Left atrial function during exercise stress echocardiography as a sign of paroxysmal/persistent atrial fibrillation. 'Color Doppler stripes' make it difficult to diagnose the severity of valvular heart diseases: a report of two cases. Effects of smoking cessation on endothelial function as assessed by flow-mediated total dilation. Ultrasound enhancing agents in cardiovascular imaging: expanding horizons beyond coronary arteries.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1