Roberto W Dal Negro, Paola Turco, Massimiliano Povero
{"title":"患者肺功能对吸气气流率的贡献通过dpi模拟器再现不同的固有阻力率。","authors":"Roberto W Dal Negro, Paola Turco, Massimiliano Povero","doi":"10.4081/mrm.2021.752","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>The performance of DPIs depends on several physiological (patient-dependent) and technological (device-dependent) factors. The inspiratory airflow rate is the only active force generated and operating in the system for inducing the required pressure drop and eliciting the resistance-induced turbulence needed to disaggregate the powder through the device. The present study aimed to investigate in the most prevalent respiratory disorders whether and at what extent the inspiratory airflow rate achievable when inhaling through a DPIs' simulator reproducing different intrinsic resistance regimens (low, mid, and high resistance) is affected by peculiar changes in lung function and/or can be predicted by any specific lung function parameter.</p><p><strong>Methods: </strong>The inspiratory airflow rate was assessed in randomized order by the In-Check DIAL G16 at low, mid, and high resistance regimens in a sample of consecutive subjects at recruitment. Independent predictors of the probability to achieve the expected inhalation airflow rate were investigated by means of a multivariate logistic regression model, specific to the disease.</p><p><strong>Results: </strong>A total of 114 subjects were recruited (asthmatics n=30; COPD n=50, restrictive patients n=16, and normal subjects n=18). The mean values of the expected inspiratory airflow rate achieved proved significantly different within the groups (p<0.0001), independently of sex and age. In asthmatics and in COPD patients, the mid-resistance regimen proved highly associated with the highest mean values of airflow rates obtained. Low- and high-resistance regimens were significantly less likely to consent to achieve the expected level of inspiratory airflow rate (OR<1 in all comparisons). Restrictive patients performed the lowest airflow rates at the low-resistance regimen (p<0.01). Unlike FEV<sup>1</sup>, RV in asthmatics (OR=1.008); RV and I<sub>Raw</sub> in COPD (OR=0.587 and OR=0.901, respectively), and FIF and TLC in restrictive patients (OR=1.041, and OR=0.962, respectively) proved the only sensitive predictors of the inspiratory airflow rate achievable at the different resistive regimens.</p><p><strong>Conclusions: </strong>The intrinsic resistive regimen of DPIs can play a critical role. The patients' lung function profile also affects the extent of their inhalation airflow rate. Some specific lung function parameters (such as: FIF; RV; I<sub>Raw</sub>; TLC, but not FEV<sub>1</sub>) may be regarded as specific predictors in real-life. In order to optimize the DPI choice, further to the device's technology, also the current patients' lung function should be properly investigated and carefully assessed.</p>","PeriodicalId":49031,"journal":{"name":"Multidisciplinary Respiratory Medicine","volume":"16 1","pages":"752"},"PeriodicalIF":2.3000,"publicationDate":"2021-04-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/d3/03/mrm-16-1-752.PMC8077610.pdf","citationCount":"3","resultStr":"{\"title\":\"The contribution of patients' lung function to the inspiratory airflow rate achievable through a DPIs' simulator reproducing different intrinsic resistance rates.\",\"authors\":\"Roberto W Dal Negro, Paola Turco, Massimiliano Povero\",\"doi\":\"10.4081/mrm.2021.752\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>The performance of DPIs depends on several physiological (patient-dependent) and technological (device-dependent) factors. The inspiratory airflow rate is the only active force generated and operating in the system for inducing the required pressure drop and eliciting the resistance-induced turbulence needed to disaggregate the powder through the device. The present study aimed to investigate in the most prevalent respiratory disorders whether and at what extent the inspiratory airflow rate achievable when inhaling through a DPIs' simulator reproducing different intrinsic resistance regimens (low, mid, and high resistance) is affected by peculiar changes in lung function and/or can be predicted by any specific lung function parameter.</p><p><strong>Methods: </strong>The inspiratory airflow rate was assessed in randomized order by the In-Check DIAL G16 at low, mid, and high resistance regimens in a sample of consecutive subjects at recruitment. Independent predictors of the probability to achieve the expected inhalation airflow rate were investigated by means of a multivariate logistic regression model, specific to the disease.</p><p><strong>Results: </strong>A total of 114 subjects were recruited (asthmatics n=30; COPD n=50, restrictive patients n=16, and normal subjects n=18). The mean values of the expected inspiratory airflow rate achieved proved significantly different within the groups (p<0.0001), independently of sex and age. In asthmatics and in COPD patients, the mid-resistance regimen proved highly associated with the highest mean values of airflow rates obtained. Low- and high-resistance regimens were significantly less likely to consent to achieve the expected level of inspiratory airflow rate (OR<1 in all comparisons). Restrictive patients performed the lowest airflow rates at the low-resistance regimen (p<0.01). Unlike FEV<sup>1</sup>, RV in asthmatics (OR=1.008); RV and I<sub>Raw</sub> in COPD (OR=0.587 and OR=0.901, respectively), and FIF and TLC in restrictive patients (OR=1.041, and OR=0.962, respectively) proved the only sensitive predictors of the inspiratory airflow rate achievable at the different resistive regimens.</p><p><strong>Conclusions: </strong>The intrinsic resistive regimen of DPIs can play a critical role. The patients' lung function profile also affects the extent of their inhalation airflow rate. Some specific lung function parameters (such as: FIF; RV; I<sub>Raw</sub>; TLC, but not FEV<sub>1</sub>) may be regarded as specific predictors in real-life. In order to optimize the DPI choice, further to the device's technology, also the current patients' lung function should be properly investigated and carefully assessed.</p>\",\"PeriodicalId\":49031,\"journal\":{\"name\":\"Multidisciplinary Respiratory Medicine\",\"volume\":\"16 1\",\"pages\":\"752\"},\"PeriodicalIF\":2.3000,\"publicationDate\":\"2021-04-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/d3/03/mrm-16-1-752.PMC8077610.pdf\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Multidisciplinary Respiratory Medicine\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.4081/mrm.2021.752\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2021/1/15 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Multidisciplinary Respiratory Medicine","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4081/mrm.2021.752","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2021/1/15 0:00:00","PubModel":"eCollection","JCR":"","JCRName":"","Score":null,"Total":0}
The contribution of patients' lung function to the inspiratory airflow rate achievable through a DPIs' simulator reproducing different intrinsic resistance rates.
Background: The performance of DPIs depends on several physiological (patient-dependent) and technological (device-dependent) factors. The inspiratory airflow rate is the only active force generated and operating in the system for inducing the required pressure drop and eliciting the resistance-induced turbulence needed to disaggregate the powder through the device. The present study aimed to investigate in the most prevalent respiratory disorders whether and at what extent the inspiratory airflow rate achievable when inhaling through a DPIs' simulator reproducing different intrinsic resistance regimens (low, mid, and high resistance) is affected by peculiar changes in lung function and/or can be predicted by any specific lung function parameter.
Methods: The inspiratory airflow rate was assessed in randomized order by the In-Check DIAL G16 at low, mid, and high resistance regimens in a sample of consecutive subjects at recruitment. Independent predictors of the probability to achieve the expected inhalation airflow rate were investigated by means of a multivariate logistic regression model, specific to the disease.
Results: A total of 114 subjects were recruited (asthmatics n=30; COPD n=50, restrictive patients n=16, and normal subjects n=18). The mean values of the expected inspiratory airflow rate achieved proved significantly different within the groups (p<0.0001), independently of sex and age. In asthmatics and in COPD patients, the mid-resistance regimen proved highly associated with the highest mean values of airflow rates obtained. Low- and high-resistance regimens were significantly less likely to consent to achieve the expected level of inspiratory airflow rate (OR<1 in all comparisons). Restrictive patients performed the lowest airflow rates at the low-resistance regimen (p<0.01). Unlike FEV1, RV in asthmatics (OR=1.008); RV and IRaw in COPD (OR=0.587 and OR=0.901, respectively), and FIF and TLC in restrictive patients (OR=1.041, and OR=0.962, respectively) proved the only sensitive predictors of the inspiratory airflow rate achievable at the different resistive regimens.
Conclusions: The intrinsic resistive regimen of DPIs can play a critical role. The patients' lung function profile also affects the extent of their inhalation airflow rate. Some specific lung function parameters (such as: FIF; RV; IRaw; TLC, but not FEV1) may be regarded as specific predictors in real-life. In order to optimize the DPI choice, further to the device's technology, also the current patients' lung function should be properly investigated and carefully assessed.
期刊介绍:
Multidisciplinary Respiratory Medicine is the official journal of the Italian Respiratory Society - Società Italiana di Pneumologia (IRS/SIP). The journal publishes on all aspects of respiratory medicine and related fields, with a particular focus on interdisciplinary and translational research.
The interdisciplinary nature of the journal provides a unique opportunity for researchers, clinicians and healthcare professionals across specialties to collaborate and exchange information. The journal provides a high visibility platform for the publication and dissemination of top quality original scientific articles, reviews and important position papers documenting clinical and experimental advances.