阻塞性睡眠呼吸暂停综合征和夜间高血压患者持续气道正压依从性和血压降低。

IF 1.8 4区 医学 Blood Pressure Pub Date : 2021-08-01 Epub Date: 2021-05-11 DOI:10.1080/08037051.2021.1922267
Jia-Hui Xia, Yuan-Yuan Kang, Yi-Bang Cheng, Qi-Fang Huang, Ting-Yan Xu, Yan Li, Ji-Guang Wang
{"title":"阻塞性睡眠呼吸暂停综合征和夜间高血压患者持续气道正压依从性和血压降低。","authors":"Jia-Hui Xia,&nbsp;Yuan-Yuan Kang,&nbsp;Yi-Bang Cheng,&nbsp;Qi-Fang Huang,&nbsp;Ting-Yan Xu,&nbsp;Yan Li,&nbsp;Ji-Guang Wang","doi":"10.1080/08037051.2021.1922267","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>We investigated continuous positive airway pressure (CPAP) adherence and its association with the blood pressure (BP) and pulse rate changes in patients with obstructive sleep apnoea syndrome (OSAS) and hypertension.</p><p><strong>Materials and methods: </strong>In a single-blind trial, patients were randomly assigned to CPAP or sham CPAP treatment for 3 months. We performed clinic, ambulatory and home BP measurements at baseline and during follow-up. CPAP adherence was assessed as the CPAP frequency per week and time per night. Non-adherence was defined as a CPAP use for <5 days/week or <4 h/night.</p><p><strong>Results: </strong>In the CPAP (<i>n</i> = 26) and sham CPAP groups (<i>n</i> = 21), the CPAP frequency was 5.5 and 4.8 days/week (<i>p</i> = 0.17), respectively, and the CPAP time was 5.0 and 4.1 h/night (<i>p</i> = 0.03), respectively. The corresponding prevalence of non-adherence was 46.2% and 66.7% (<i>p</i> = 0.16), respectively. The CPAP frequency but not time tended to be associated with the changes in BP and pulse rate at 3 months of follow-up, especially home systolic/diastolic BP in the CPAP group (3.2/1.3 mmHg greater reductions per 1 day increment, <i>p</i> ≤ 0.01). Adherent, compared with non-adherent patients, had greater reductions in BP or pulse rate at 3 months of follow-up. In the CPAP and sham CPAP groups combined, statistical significance was achieved for the adjusted between adherence and non-adherence differences in home systolic/diastolic BP (-5.0/-3.8 mmHg) and 24-h, daytime and night-time ambulatory pulse rate (-6.2, -7.8 and -4.4 beats/min, respectively, <i>p</i> ≤ 0.04).</p><p><strong>Conclusion: </strong>CPAP adherence was associated with the BP lowering and pulse rate slowing effects, especially the CPAP frequency.</p>","PeriodicalId":9000,"journal":{"name":"Blood Pressure","volume":null,"pages":null},"PeriodicalIF":1.8000,"publicationDate":"2021-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1080/08037051.2021.1922267","citationCount":"1","resultStr":"{\"title\":\"Continuous positive airway pressure adherence and blood pressure lowering in patients with obstructive sleep apnoea syndrome and nocturnal hypertension.\",\"authors\":\"Jia-Hui Xia,&nbsp;Yuan-Yuan Kang,&nbsp;Yi-Bang Cheng,&nbsp;Qi-Fang Huang,&nbsp;Ting-Yan Xu,&nbsp;Yan Li,&nbsp;Ji-Guang Wang\",\"doi\":\"10.1080/08037051.2021.1922267\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>We investigated continuous positive airway pressure (CPAP) adherence and its association with the blood pressure (BP) and pulse rate changes in patients with obstructive sleep apnoea syndrome (OSAS) and hypertension.</p><p><strong>Materials and methods: </strong>In a single-blind trial, patients were randomly assigned to CPAP or sham CPAP treatment for 3 months. We performed clinic, ambulatory and home BP measurements at baseline and during follow-up. CPAP adherence was assessed as the CPAP frequency per week and time per night. Non-adherence was defined as a CPAP use for <5 days/week or <4 h/night.</p><p><strong>Results: </strong>In the CPAP (<i>n</i> = 26) and sham CPAP groups (<i>n</i> = 21), the CPAP frequency was 5.5 and 4.8 days/week (<i>p</i> = 0.17), respectively, and the CPAP time was 5.0 and 4.1 h/night (<i>p</i> = 0.03), respectively. The corresponding prevalence of non-adherence was 46.2% and 66.7% (<i>p</i> = 0.16), respectively. The CPAP frequency but not time tended to be associated with the changes in BP and pulse rate at 3 months of follow-up, especially home systolic/diastolic BP in the CPAP group (3.2/1.3 mmHg greater reductions per 1 day increment, <i>p</i> ≤ 0.01). Adherent, compared with non-adherent patients, had greater reductions in BP or pulse rate at 3 months of follow-up. In the CPAP and sham CPAP groups combined, statistical significance was achieved for the adjusted between adherence and non-adherence differences in home systolic/diastolic BP (-5.0/-3.8 mmHg) and 24-h, daytime and night-time ambulatory pulse rate (-6.2, -7.8 and -4.4 beats/min, respectively, <i>p</i> ≤ 0.04).</p><p><strong>Conclusion: </strong>CPAP adherence was associated with the BP lowering and pulse rate slowing effects, especially the CPAP frequency.</p>\",\"PeriodicalId\":9000,\"journal\":{\"name\":\"Blood Pressure\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.8000,\"publicationDate\":\"2021-08-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1080/08037051.2021.1922267\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Blood Pressure\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1080/08037051.2021.1922267\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2021/5/11 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Blood Pressure","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1080/08037051.2021.1922267","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2021/5/11 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

目的:研究阻塞性睡眠呼吸暂停综合征(OSAS)合并高血压患者持续气道正压通气(CPAP)依从性及其与血压(BP)和脉搏变化的关系。材料和方法:在单盲试验中,患者被随机分配到CPAP或假CPAP治疗3个月。我们在基线和随访期间进行了门诊、门诊和家庭血压测量。CPAP依从性评估为每周CPAP频率和每晚CPAP时间。结果:在CPAP组(n = 26)和假CPAP组(n = 21)中,CPAP频率分别为5.5和4.8天/周(p = 0.17), CPAP时间分别为5.0和4.1小时/晚(p = 0.03)。相应的不依从率分别为46.2%和66.7% (p = 0.16)。随访3个月时,CPAP频率与血压和脉搏变化相关,而时间与之无关,特别是CPAP组的家庭收缩压/舒张压(每增加1天降低3.2/1.3 mmHg, p≤0.01)。在3个月的随访中,与非依从性患者相比,依从性患者的血压或脉搏率下降幅度更大。在CPAP和sham CPAP联合组中,依从性和非依从性的家庭收缩压/舒张压(-5.0/-3.8 mmHg)和24小时、白白夜动态脉搏率(-6.2、-7.8和-4.4次/分钟,p≤0.04)的调整差异具有统计学意义。结论:CPAP依从性与血压降低和脉率减慢有关,尤其是CPAP频率。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Continuous positive airway pressure adherence and blood pressure lowering in patients with obstructive sleep apnoea syndrome and nocturnal hypertension.

Purpose: We investigated continuous positive airway pressure (CPAP) adherence and its association with the blood pressure (BP) and pulse rate changes in patients with obstructive sleep apnoea syndrome (OSAS) and hypertension.

Materials and methods: In a single-blind trial, patients were randomly assigned to CPAP or sham CPAP treatment for 3 months. We performed clinic, ambulatory and home BP measurements at baseline and during follow-up. CPAP adherence was assessed as the CPAP frequency per week and time per night. Non-adherence was defined as a CPAP use for <5 days/week or <4 h/night.

Results: In the CPAP (n = 26) and sham CPAP groups (n = 21), the CPAP frequency was 5.5 and 4.8 days/week (p = 0.17), respectively, and the CPAP time was 5.0 and 4.1 h/night (p = 0.03), respectively. The corresponding prevalence of non-adherence was 46.2% and 66.7% (p = 0.16), respectively. The CPAP frequency but not time tended to be associated with the changes in BP and pulse rate at 3 months of follow-up, especially home systolic/diastolic BP in the CPAP group (3.2/1.3 mmHg greater reductions per 1 day increment, p ≤ 0.01). Adherent, compared with non-adherent patients, had greater reductions in BP or pulse rate at 3 months of follow-up. In the CPAP and sham CPAP groups combined, statistical significance was achieved for the adjusted between adherence and non-adherence differences in home systolic/diastolic BP (-5.0/-3.8 mmHg) and 24-h, daytime and night-time ambulatory pulse rate (-6.2, -7.8 and -4.4 beats/min, respectively, p ≤ 0.04).

Conclusion: CPAP adherence was associated with the BP lowering and pulse rate slowing effects, especially the CPAP frequency.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Blood Pressure
Blood Pressure Medicine-Cardiology and Cardiovascular Medicine
CiteScore
3.20
自引率
5.60%
发文量
41
期刊介绍: For outstanding coverage of the latest advances in hypertension research, turn to Blood Pressure, a primary source for authoritative and timely information on all aspects of hypertension research and management. Features include: • Physiology and pathophysiology of blood pressure regulation • Primary and secondary hypertension • Cerebrovascular and cardiovascular complications of hypertension • Detection, treatment and follow-up of hypertension • Non pharmacological and pharmacological management • Large outcome trials in hypertension.
期刊最新文献
Mission 70/26 Project: improving blood pressure control in Portugal. Factors associated with progression of arterial stiffness in ischemic stroke survivors: the Norwegian Stroke in the Young Study. The impact of prediabetes and diabetes on endothelial function in a large population-based cohort. The relationship between mid-upper arm circumference and blood pressure in Walter Sisulu University community. Habitual food consumption, eating behavior and meal-timing among Jordanian adults with elevated Blood pressure: a cross-sectional population-based study.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1