患者对口内扫描的看法:传统牙科印模与数字牙科印模的比较。

IF 0.8 4区 医学 Q4 ENDOCRINOLOGY & METABOLISM Journal of biological regulators and homeostatic agents Pub Date : 2021-05-01 DOI:10.23812/21-3supp1-4
A Giancotti, G Mampieri, F Paoncelli, M Greco, C Arcuri
{"title":"患者对口内扫描的看法:传统牙科印模与数字牙科印模的比较。","authors":"A Giancotti, G Mampieri, F Paoncelli, M Greco, C Arcuri","doi":"10.23812/21-3supp1-4","DOIUrl":null,"url":null,"abstract":"<p><p>The purpose of this work was to assess the discomfort perceived by the patient during the intraoral scan procedure using the iTero Scanner. A sample of 33 patients was selected on the basis of parameters that identify a complete dentition. All treated patients underwent a traditional polyvinylsiloxane impression with double procedure and an intraoral scan in the same session. Subsequently they were given a questionnaire concerning the discomfort perceived by both procedures. Once the completed questionnaires were obtained, preliminary statistical tests were carried out to check if the distribution of scores assigned by patients to the two procedures differed significantly from a Gaussian distribution. Furthermore, the discomfort/preference indexes for the two procedures were compared using the Wilcoxon test for paired data. Finally, the Spearman correlation test was used. From the results of the preliminary normality tests, it was decided to use nonparametric type tests that gives the intraoral scan procedure more favorable scores relative to a minor discomfort. The use of intraoral scanning and more specifically of the iTero 2.9 scanner (despite a not small wand), represents an option largely preferred by patients in terms of reduction of discomfort and classic discomfort related to relief systems traditional imprint.</p>","PeriodicalId":15084,"journal":{"name":"Journal of biological regulators and homeostatic agents","volume":"35 3 Suppl. 1","pages":"19-28"},"PeriodicalIF":0.8000,"publicationDate":"2021-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Patient's perception of intraoral scanning: a comparison between traditional and digital dental impression.\",\"authors\":\"A Giancotti, G Mampieri, F Paoncelli, M Greco, C Arcuri\",\"doi\":\"10.23812/21-3supp1-4\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The purpose of this work was to assess the discomfort perceived by the patient during the intraoral scan procedure using the iTero Scanner. A sample of 33 patients was selected on the basis of parameters that identify a complete dentition. All treated patients underwent a traditional polyvinylsiloxane impression with double procedure and an intraoral scan in the same session. Subsequently they were given a questionnaire concerning the discomfort perceived by both procedures. Once the completed questionnaires were obtained, preliminary statistical tests were carried out to check if the distribution of scores assigned by patients to the two procedures differed significantly from a Gaussian distribution. Furthermore, the discomfort/preference indexes for the two procedures were compared using the Wilcoxon test for paired data. Finally, the Spearman correlation test was used. From the results of the preliminary normality tests, it was decided to use nonparametric type tests that gives the intraoral scan procedure more favorable scores relative to a minor discomfort. The use of intraoral scanning and more specifically of the iTero 2.9 scanner (despite a not small wand), represents an option largely preferred by patients in terms of reduction of discomfort and classic discomfort related to relief systems traditional imprint.</p>\",\"PeriodicalId\":15084,\"journal\":{\"name\":\"Journal of biological regulators and homeostatic agents\",\"volume\":\"35 3 Suppl. 1\",\"pages\":\"19-28\"},\"PeriodicalIF\":0.8000,\"publicationDate\":\"2021-05-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of biological regulators and homeostatic agents\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.23812/21-3supp1-4\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"ENDOCRINOLOGY & METABOLISM\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of biological regulators and homeostatic agents","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.23812/21-3supp1-4","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENDOCRINOLOGY & METABOLISM","Score":null,"Total":0}
引用次数: 0

摘要

这项工作的目的是评估患者在使用 iTero 扫描仪进行口内扫描过程中感受到的不适。根据确定完整牙列的参数,选取了 33 名患者作为样本。所有接受治疗的患者都在同一疗程中接受了传统的聚乙烯硅氧烷印模和口内扫描。随后,他们会收到一份调查问卷,内容涉及两种程序带来的不适感。在获得填写完整的问卷后,我们进行了初步统计测试,以检验患者对两种程序的评分分布是否与高斯分布有明显差异。此外,还使用配对数据的 Wilcoxon 检验比较了两种手术的不适/偏好指数。最后,还使用了斯皮尔曼相关性检验。根据初步的正态性检验结果,我们决定使用非参数类型检验,即相对于轻微不适感,口内扫描程序的得分更高。使用口内扫描,特别是 iTero 2.9 扫描仪(尽管扫描棒不小),在减轻不适感和与缓解系统传统印记有关的典型不适感方面,是一种深受患者青睐的选择。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Patient's perception of intraoral scanning: a comparison between traditional and digital dental impression.

The purpose of this work was to assess the discomfort perceived by the patient during the intraoral scan procedure using the iTero Scanner. A sample of 33 patients was selected on the basis of parameters that identify a complete dentition. All treated patients underwent a traditional polyvinylsiloxane impression with double procedure and an intraoral scan in the same session. Subsequently they were given a questionnaire concerning the discomfort perceived by both procedures. Once the completed questionnaires were obtained, preliminary statistical tests were carried out to check if the distribution of scores assigned by patients to the two procedures differed significantly from a Gaussian distribution. Furthermore, the discomfort/preference indexes for the two procedures were compared using the Wilcoxon test for paired data. Finally, the Spearman correlation test was used. From the results of the preliminary normality tests, it was decided to use nonparametric type tests that gives the intraoral scan procedure more favorable scores relative to a minor discomfort. The use of intraoral scanning and more specifically of the iTero 2.9 scanner (despite a not small wand), represents an option largely preferred by patients in terms of reduction of discomfort and classic discomfort related to relief systems traditional imprint.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
2.20
自引率
15.60%
发文量
0
审稿时长
6 months
期刊介绍: Journal of Biological Regulators & Homeostatic Agents (IF 1.397) is a peer-reviewed journal published every 2 months. The journal publishes original papers describing research in the fields of experimental and clinical medicine, molecular biology, biochemistry, regulatory molecules, cellular immunology and pharmacology.
期刊最新文献
Targeted regulation of BBOX1-AS1 on miR-361-3p and its effect on the biological function of non-small cell lung cancer cell. Plasma brain natriuretic peptide levels in children with idiopathic epilepsy treated with longterm sodium valproate and oxcarbazepine monotherapy. Silenced fatty acid-binding protein 4 suppresses epithelial-mesenchymal transition of endometriosis via the phosphatidyl inositol 3-kinase/protein kinase B axis. Analysis of long non-coding RNA expression profiles in disuse osteoporosis using microarray and bioinformatics. Identification of miRNAs, mRNAs, lncRNAs, and circRNAs associated with hepatocellular carcinoma recurrence after interferon treatment.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1