密封可运输细胞中氧的三重点。

George T Furukawa
{"title":"密封可运输细胞中氧的三重点。","authors":"George T Furukawa","doi":"10.6028/jres.091.031","DOIUrl":null,"url":null,"abstract":"<p><p>The triple points of oxygen samples sealed in miniature pressure cells were investigated by means of adiabatic calorimetry. The triple point of a 99.999 percent pure commercial oxygen sample was found to be 0.94<sub>0</sub> mK higher than that of an \"ultra-pure\" sample prepared by thermal decomposition of potassium permanganate (KMnO<sub>4</sub>). The higher value is attributed principally to argon impurity in the commercial oxygen. The results of eight sets of observations using six thermometers, calibrated on the International Practical Temperature Scale of 1968 as maintained at the National Bureau of Standards, and two sealed cells of the ultra-pure oxygen show a range of 0.17<sub>8</sub> mK. The capsule-type platinum resistance thermometers that have been used are shown to have outstanding stability and the multiple calibrations made on them at the National Bureau of Standards extending over six years are shown to be consistent to within 0.15 mK at 54.361 K. The results of measurements on an internationally circulated sealed cell of commercial oxygen show its temperature to be 0.58<sub>1</sub> mK higher than those of the ultra-pure oxygen.</p>","PeriodicalId":93321,"journal":{"name":"Journal of research of the National Bureau of Standards (1977)","volume":"91 5","pages":"255-275"},"PeriodicalIF":0.0000,"publicationDate":"1986-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6687591/pdf/jres-91-255.pdf","citationCount":"12","resultStr":"{\"title\":\"The Triple Point of Oxygen In Sealed Transportable Cells.\",\"authors\":\"George T Furukawa\",\"doi\":\"10.6028/jres.091.031\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The triple points of oxygen samples sealed in miniature pressure cells were investigated by means of adiabatic calorimetry. The triple point of a 99.999 percent pure commercial oxygen sample was found to be 0.94<sub>0</sub> mK higher than that of an \\\"ultra-pure\\\" sample prepared by thermal decomposition of potassium permanganate (KMnO<sub>4</sub>). The higher value is attributed principally to argon impurity in the commercial oxygen. The results of eight sets of observations using six thermometers, calibrated on the International Practical Temperature Scale of 1968 as maintained at the National Bureau of Standards, and two sealed cells of the ultra-pure oxygen show a range of 0.17<sub>8</sub> mK. The capsule-type platinum resistance thermometers that have been used are shown to have outstanding stability and the multiple calibrations made on them at the National Bureau of Standards extending over six years are shown to be consistent to within 0.15 mK at 54.361 K. The results of measurements on an internationally circulated sealed cell of commercial oxygen show its temperature to be 0.58<sub>1</sub> mK higher than those of the ultra-pure oxygen.</p>\",\"PeriodicalId\":93321,\"journal\":{\"name\":\"Journal of research of the National Bureau of Standards (1977)\",\"volume\":\"91 5\",\"pages\":\"255-275\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1986-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6687591/pdf/jres-91-255.pdf\",\"citationCount\":\"12\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of research of the National Bureau of Standards (1977)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.6028/jres.091.031\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of research of the National Bureau of Standards (1977)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.6028/jres.091.031","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 12

摘要

用绝热量热法研究了密封在微型压力电池中的氧样品的三相点。99.999%纯商业氧气样品的三重点比通过高锰酸钾(KMnO4)热分解制备的“超纯”样品高0.940mK。较高的值主要归因于商业氧气中的氩杂质。使用六个温度计和两个超纯氧密封池进行的八组观测结果显示,温度范围为0.178mK。已使用的胶囊型铂电阻温度计显示出卓越的稳定性,国家标准局对其进行的六年多的多次校准显示,在54.361 K的温度下,其一致性在0.15 mK以内。在国际循环的商用氧气密封池上的测量结果表明,其温度比超纯氧的温度高0.581mK。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
The Triple Point of Oxygen In Sealed Transportable Cells.

The triple points of oxygen samples sealed in miniature pressure cells were investigated by means of adiabatic calorimetry. The triple point of a 99.999 percent pure commercial oxygen sample was found to be 0.940 mK higher than that of an "ultra-pure" sample prepared by thermal decomposition of potassium permanganate (KMnO4). The higher value is attributed principally to argon impurity in the commercial oxygen. The results of eight sets of observations using six thermometers, calibrated on the International Practical Temperature Scale of 1968 as maintained at the National Bureau of Standards, and two sealed cells of the ultra-pure oxygen show a range of 0.178 mK. The capsule-type platinum resistance thermometers that have been used are shown to have outstanding stability and the multiple calibrations made on them at the National Bureau of Standards extending over six years are shown to be consistent to within 0.15 mK at 54.361 K. The results of measurements on an internationally circulated sealed cell of commercial oxygen show its temperature to be 0.581 mK higher than those of the ultra-pure oxygen.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
The Temperature Dependence of Spectral Broadening in the Hg (61S0-63P1) Multiplet At High Optical Densities. Absolute Isotopic Abundance Ratio And Atomic Weight Of a Reference Sample of Gallium. Thermal Expansion of Platinum And Platinum-Rhodium Alloys. The Triple Point of Oxygen In Sealed Transportable Cells. A Multi-kilogram Capacity Calorimeter For Heterogeneous Materials.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1